1
Content available remote High-resolution multichannel measurement and analysis of cardiac repolarization
EN
Time and spatial inhomogeneity of the repolarization phase is considered to be an important, noninvasive indication of sudden cardiac death in patients after myocardial infarction. Analysis of spatial variability of the repolarization phase was carried out on signals recorded with the 64-channel system for measurement of high-resolution ECG. The lead position on the torso, according to the University of Amsterdam lead system, was used. A new parameter, called the T-wave shape index and the distribution function method, as a method sensitive to shape variations, were applied to examine spatial variability of the T-wave shape in HR ECG maps. A group of 14 healthy volunteers and a group of 12 patients after myocardial infarction were studied. The diversity of spatial distributions of the parameters connected to the shape of the T-wave is clearly noticeable in the group of patients after myocardial infarction. The similarity of spatial distributions of proposed parameters in the group of healthy subjects is observed. The obtained results confirm the hypothesis that the spatial heterogeneity of the repolarization phase increases after myocardial infarction.
EN
A new filtering technique for high-resolution ECG signals processing is proposed. The filter is based on approximation of the electrocardiogram segments by polynoms of low degree with possibility of including smoothing constraints at the frontier points. The segments localization, the polynomial degree and the continuity constraints are discussed in details. Finally it is shown that the proposed filter, without continuity cinstraints is FIR, linear and shift invariant. The filter may find application in analysis of the heart micropotentials, especially late potentials. In this case the idea is to match the filter to the high amplitude segments of the ECG in order to limit their influence in the part of the signal where micropotentials are expected. The preliminary results obtained for post-infartion patients show that the filtration allows for clear detection ob abnormal electrical activity in the terminal part of the QRS complex.
PL
Celem niniejszej pracy było oszacowanie wpływu miejsca wystąpienia zawału mięśnia sercowego na efektywność wykrywania pacjentów zagrożonych częstoskurczem komorowym na podstawie analizy EKG o wysokiej rozdzielczości. Wyniki analiz wysokorozdzielczego EKG w dziedzinie czasu i częstości byty rozpatrywane pod względem umiejscowienia zawału mięśnia sercowego w ścianie przedniej lub dolnej. Poniższa praca potwierdza wpływ lokalizacji zawału mięśnia sercowego na efektywność oceny zagrożenia częstoskurczem komorowym za pomocą wysoko-rozdzielczej analizy EKG.
EN
The purpose of this study was to evaluate the influence of the location of myocardial infarction (MI) on the effectiveness of the high resolution ECG analysis in discriminating patients prone to ventricular tachycardia (VT). The results of the high resolution ECG analysis in time and frequency domain were compared in respect of the anterior (AMI) and inferior (IMI) myocardial infarction. The presented study confirms the influence of the MI localization on the effectiveness of VT prediction by the high-resolution ECG analysis. This influence was less obvious for the AR and WT analyses due to high frequency resolution of these methods.
4
Content available remote Signal averaging and variability estimation in high resolution ECG
EN
The ECG signal digitised with a high resolution level (HR ECG) is a non invasive way more and more used in clinical centres to analyze heart electrical activity. The Signal Averaging technique is commonly used to eliminate the noisy part of the recordings. A synthesis of some of our published works is presented with the aim to take into account both the repetitivity and the variability of cardiac signals coming from HR ECG. Signal averaging is analysed specially when the ideal case of equal shape and equal width signals cannot be assumed. The measure of shape or shape and width differences is applied both to the natural variability to improve averaging and to variations induced by external agents such as the action of a drug.
PL
Elektrokardiografia o wysokiej rozdzielczości (HR-EKG) jest coraz bardziej popularną nieinwazyjną metodą analizy elektrycznej czynności serca w wielu ośrodkach klinicznych. Technika uśredniania sygnałów jest powszechnie stosowana do eliminacji składowej szumu w zarejestrowanych sygnałach. W pracy przedstawiono syntezę kilku wybranych opublikowanych wcześniej prac, które uwzględniały aspekty powtarzalności jak i zmienności sygnałów elektrokardiograficznych rejestrowanych techniką o wysokiej rozdzielczości. Uśrednianie sygnałów jest analizowane głównie w przypadku gdy nie można założyć równości kształtu i szerokości cykli sygnału. Wskaźnik różnic kształtu lub kształtu i szerokości został zastosowany zarówno w przypadku naturalnej zmienności w celu poprawy uśredniania oraz dla zmian wywołanych środkami zewnętrznymi takimi jak działanie leków.