Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Numerical modelling of innovative DST steel joint under cyclic loading
EN
This paper addresses the numerical simulation of an innovative double split Tee beam-to-column joint fitted with a dissipative friction damper, recently proposed at the University of Salerno. The innovative connection prevents damage to all other structural components with the exception of one component of the connection that is specially designed to dissipate the input energy of a seismic hazard by means of the slippage of a friction material. The main topics herein presented are the development of a strategy for the numerical modelling of complex friction problems and a detailed numerical model of the overall beam-to-column joint equipped with the friction device. The joint is subjected to both monotonic and cyclic loading conditions. The numerical modelling was developed using the Finite Elements Method (FEM) with Abaqus Software. Sliding force–displacement curves are obtained for two damper materials and an estimation of their wearing is presented. To evaluate the accuracy of the numerical model, moment–rotation curves of the joint are compared with the experimental curves. The FE results show good correlations and confirm the potential interest of this novel joint typology to achieve easily replaceable details in case of a seismic event.
EN
The aim of this paper is to analyze the possibility to improve the seismic performance of cross-laminated timber (CLT) panel buildings introducing in the structure dissipative connectors in substitution of the classical hold-downs. In fact, as demonstrated by past experimental tests and numerical analyses, hold-downs exhibit a limited dissipation capacity. The proposed dissipative connector is called XL-stub and applies the concept usually adopted for ADAS devices. In order to prove the effectiveness of the proposed system the results of an experimental program devoted to characterize the force–displacement response under cyclic loads and low fatigue behavior of the XL-stub are presented and compared to the results of cyclic tests of hold-downs with same resistance. Afterwards, the comparison is extended at the level of the building, evaluating the influence of the connection on the seismic performance of the whole CLT panel building. To this scope, a FE model of the three-storey building tested within the SOFIE project is calibrated and multiple transient dynamic analyses are performed both for the building with the classical layout of connections and for the building equipped with XL-stubs. The obtained results are compared and the values of the behavior factor for the two solutions are calculated.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.