The study of the kinetics and statics of cobalt adsorption at the hydroxyapatite/electrolyte interface using radioactive isotope 60Co was conducted. The course of adsorption kinetics indicates that at the beginning adsorption proceeds quickly and then slowly. Such adsorption kinetics is best described by a multiexpotential equation. The analysis of cobalt adsorption as a function of pH and the results of H+ ions desorption/adsorption confirmed that cobalt adsorption proceeds due to ion exchange with calcium ions in the crystal lattice and hydrogen ions in the surface groups of hydroxyapatite. Cobalt ions adsorption results in the increase of the electrokinetic potential but for the solution of the initial concentration of 0.001 mol/dm3 at pH = 8.17 a reversal of the charge due to overloading of the compact layer (edl) is observed.
Previous studies have demonstrated that, the length of the lumbar spine is decreasing with age. Despite considerable research based on sagittal measurements, little is known about the changes in the volume of vertebrae. The objective of this study was to evaluate the changes in the volume of either column of the spine with age. Materials and methods: Computed tomography scans of 62 asymptomatic subjects, performed for thoracolumbar trauma evaluation were used to create virtual 3D models. At least 10 patients were assigned to every decade of life from third to eight. We used a novel technique to measure the volume of anterior column (AC) and posterior column (PC) per each segment (a total of 310 segments). Midline sagittal images were used to measure disc height (DH) and vertebral body height (VH). Results: With age, both DH increases, whereas the VH decreases. The overall length of lumbar segment of the spine decreases with age. The volumetric measurements performed on same subjects showed that volume of both AC and PC does not change with age in females. In males, there is a weak but statistically significant correlation between AC volume and age and no change in the volume of PC. The ratio of PC:AC volume does not change with age in women, although it decreases slightly but significantly (in favor of AC) with age in males. Conclusions: The overall length of lumbar spine decreases with age. This process is not a result of mere changes in the volume of either AC or PC.
The mechanism, kinetic and static studies of fructose adsorption at the alumina/electrolyte interface using radiolabeled 14C-fructose were conducted. Pseudo 2nd order model of adsorption kinetics was found to fit best to adsorption as a function of time. The fructose adsorption was found to decrease with increasing pH of the solution. Considering the changes in concentration of surface groups at the alumina/electrolyte interface, the hydrogen bonding is the most probable mechanism of interaction of fructose with the surface. This is confirmed by calorimetric titration experiments because the measured heat of adsorption was 10.8 kJ/mol. For the system studied the coverage of surface by fructose was several times smaller than the monolayer.
Due to potential application of rhenium sulphide in medicine and industry, this study is focused on the properties of synthetic and commercial rhenium sulphide. The main reaction of rhenium sulphide preparation involves potassium perrhenate and sodium thiosulphate in the acidic environment giving a mixture of rhenium sulphide and sulphur. The next step is removing sulphur by its dissolution in ether. Stabilization by Povidone K-25 is needed to obtain rhenium sulphide dispersed with the grain size of 0.5–4 m. The extrapolated value of pHiep for synthesised rhenium sulphide is 2.3 whereas for commercial samples this value is lower than 2. For synthetic sample a dependence of zeta potential on the carrier electrolyte concentration is found. It is larger than that for the commercial sample, probably due to surface oxidation during synthesis or purification.
Przemieszczenia punktów kontrolowanych, rozmieszczonych na monitorowanej budowli wyznacza się w stosunku do pozycji punktów stałych. Punkty stałe rozmieszcza się obok lub wokół monitorowanej budowli, poza strefą przemieszczeń wywołanych jej istnieniem i eksploatacją. Uznaje się, że punkty są stałe, gdy nie podlegają zmianom wzajemnego położenia. Jednak nie ma gwarancji, że punkty stałe nie podlegają innym siłom, nie związanym z oddziaływaniem monitorowanej budowli, lecz wywołującym ich wzajemne przemieszczenia. W przypadkach takich przemieszczenia punktów kontrolowanych na monitorowanym obiekcie trzeba wyznaczać na odmiennych zasadach. W pracy przedstawiono przykład wyznaczenia przemieszczeń obwałowania zbiornika wodnego w dwu wariantach: - w odniesieniu do punktów stałych, co do których powstały wątpliwości, czy rzeczywiście są stałe, - w odniesieniu do punktów na koronie obwałowania. Okazało się, że wariant drugi ma istotne zalety w stosunku do wyznaczania przemieszczeń w odniesieniu do punktów stałych, których stałość budzi wątpliwości. Główne zalety to możliwość: - wyselekcjonowania przemieszczeń poszczególnych punktów stałych względem monitorowanej budowli, - możliwość obliczenia parametrów charakteryzujących deformacje budowli pod wpływem zmian jej obciążenia. Autorzy zalecają, w przypadku pojawienia się wątpliwości, czy punkty stałe rzeczywiście zachowały stałość wzajemnego położenia, równoczesne stosowanie obu wariantów wyznaczania przemieszczeń i analizowanie różnic między ich wynikami.
EN
Displacements of controlled points, located on the monitored construction, are determined in relation to fixed points. Fixed points are distributed close or around the monitored construction, outside of the zone of displacements effected by its existence and exploitation. It is assumed that points are fixed when they do not change mutual position. However, it is not guaranteed that fixed points are not susceptible to other forces, which are not related the monitored construction but cause mutual displacements. In such cases displacements of points controlled on the monitored construction should be determined using other principles. In this work an example of determining displacements of embankment of water reservoir was presented in two variants: - in relation to fixed points, which it was doubtful if they were really. fixed, - in relation to points which were displaced on the top of embankment. It was shown that the second variant is more advantageous than the first when stability of fixed points is in doubt. The main benefits of this solution are: - possibility of selecting displacements of particular fixed points in relation to the monitored construction, - possibility of calculating parameters, which characterize deformations of construction due to changes of its loading. The authors recommend that in case of doubt regarding stability of fixed control points both variants of determining displacements be applied and differences between the results analyzed.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A study on adsorption of carbonate ions at the α-Fe2O3/aqueous solution of NaClO4 interface is presented. The concentration range of carbonate ions was from 1.00䞆-6 to 1.00䞆-3 M. The shape of carbonate ion adsorption plot vs. pH is characteristic for anions adsorption onto metal oxides and is called "adsorption envelope". To prevent carbon dioxide access to the solution, all measurements were conducted in a special chamber in nitrogen atmosphere.
PL
Adsorpcja jonów węglanowych powoduje zwiększenie negatywnie naładowanych grup powierzchniowych obecnych na powierzchni hematytu i w konsekwencji spadek potencjału dzeta. Kształt krzywych adsorpcji jest charakterystyczny dla adsorpcji anionów na tlenkach metali. Obserwowane są ponadto zmiany we właściwościach powierzchniowych, np. wzrost powierzchni właściwej hematytu po adsorpcji jonów węglanowych, zmiany w rozkładzie ziarnowym, czy zmiany w widmach IR.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Adsorption of Ca(II) and Fe(III) ions at the SnO2/NaCl solution interface as well as the effect of adsorption on the structure of electrical double layer were presented in this paper. The influence of ionic strength, pH and presence of ions on adsorption of Ca(II) and Fe(III) at the SnO2/NaCl solution interface were also investigated. Adsorption was investigated in the pH range of 2 to 10. The zeta potential, surface charge density, adsorption density, pH50% and ΔpH10-90% parameters for different concentrations of carrying electrolyte were presented. The adsorption reaction constants involving the surface hydroxyl groups were determined using the numerical optimization method.
PL
Cyna i jej związki mają szereg praktycznych i istotnych zastosowań od wielu lat. Obecnie zasoby naturalne cyny są nieduże. Szacuje się, że wystarczą na około 40 lat. Dlatego należy podjąć próbę odzysku cyny z materiałów zawierających ten pierwiastek. Przeprowadzono pomiary adsorpcji jonów wapnia i żelaza, dla jego różnych stężeń początkowych, w funkcji pH dla układu SnO2/roztwór NaCl. Kształt krzywej adsorpcji w funkcji pH ma postać krawędzi adsorpcji. Wzrost stężenia początkowego jonów Ca(II) i Fe(III) powoduje przesunięcie krawędzi w kierunku zasadowym w skali pH. Wyznaczono charakterystyczne parametry krawędzi adsorpcji tj. pH50% i ΔpH10-90%. W oparciu o zależność adsorpcji od pH obliczono również stałe adsorpcji jonów Ca(II) i Fe(III). Zależność gęstości ładunku powierzchniowego od pH w obecności jonów Ca(II) i Fe(III) jest w dobrej korelacji z zależnością adsorpcji jonów Ca(II) i Fe(III) od pH. Adsorpcja jonów Ca(II) i Fe(III) na powierzchni SnO2 prowadzi do wzrostu stężenia grup ujemnie naładowanych
Omawiane tu badania oparto na zestawieniu pionowych przemieszczeń i deformacji 168 monolitycznych, żelbetowych podpór czterech równoległych rurociągów ciśnieniowych, prowadzących wodę z górnego zbiornika do turbin elektrowni szczytowo pompowej. Wyniki te zebrano w drodze dodatkowego przetworzenia 6-krotnie wyznaczonych, w latach 2003-2009, przemieszczeń reperów kontrolowanych, zastabilizowanych na podporach rurociągów. Stwierdzono, że w okresach braku zmian obciążenia rurociągów podpory podlegały wzajemnym pionowym przemieszczeniom rzędu 0,5 mm, natomiast kolejne opróżnianie rurociągów nr 3, 4 do celów remontowych i ponowne ich napełnianie powodowało znacznie większe przemieszczenia pionowe ich podpór w stosunku do podpór pozostałych rurociągów - średnio o 3 mm i maksymalnie o 7 mm. Podpory rurociągów sąsiadujących z rurociągami odciążanymi do celów remontowych i ponownie dociążanymi po zakończeniu remontu podlegały przy tym zmianom nachylenia średnio o +/- 0,2 mm/m w płaszczyźnie prostopadłej do kierunku rurociągów Nie stwierdzono wystąpienia zmian nachylenia podpór wzdłuż zbocza, tj. w płaszczyźnie równoległej do kierunku rurociągów Deformacje podpór w większości przypadków nie przekraczały +/- 0,2 mm, a średnio osiągały wartość 0,035 mm przy błędzie standardowym wyznaczenia 0,05 mm, co świadczy, że podpory były sztywne w granicach dokładności wyznaczenia. Przewiduje się w najbliższych latach dokonanie dalszych remontów połączonych z opróżnianiem jednego rurociągu i ponownym napełnianiem dwu rurociągów, co umożliwi rozszerzenie omawianych tu badań. Celem niniejszych badań jest uzyskanie informacji o możliwych przemieszczeniach i zmianach nachylenia monolitycznych podpór rurociągów oraz deformacjach podpór i podłoża w warunkach statycznych oraz pod wpływem określonych zmian obciążenia. Informacje te są niezbędne do pogłębienia oceny stanu bezpieczeństwa pracy konkretnego zespołu rurociągów ciśnieniowych oraz mogą być przydatne do poszerzenia wiedzy o sposobie reagowania podłoża fundamentów budowli usytuowanych na zboczach terenu na zmiany obciążenia i do ewentualnych nowelizacji norm określających dopuszczalne przemieszczenia.
EN
Examinations presented in this article are based on analysis of vertical displacements and deformations, concerning 168 monolithic, ferroconcrete bearers of four parallel pressure pipelines, used, for water supply from upper reservoir to turbines of pumped-storage power plant. The results were collected through additional processing of displacements of controlled benchmarks, stabilized on pipeline's bearers, which were determined six times in the period 2003-2009. It was found, that in the periods, when changes of pipeline loadings did not appear, bearers were mutually vertically displaced around 0.5 mm. When pipelines No 3 and No 4 became empty for repairs and filled again, vertical displacements of their bearers in relation to the remaining bearers increased, 3 mm on the average and 7 mm maximum. Bearers of pipelines, which neighbor with the unloaded/loaded pipelines were subject additionally to changes of inclination, +/- 0.2 mm/m on the average in the plane perpendicular to direction of pipelines. Changes in inclination of bearers along a slope, i.e. in the plane parallel to direction of pipelines, were not found. Deformations of bearers in majority did not exceed +/- 0.2 mm, reaching mean value of 0.035 mm, with 0.03 mm standard deviation, which confirms, that bearers were stiff within accuracy limits. Further repairs combined with emptying one pipeline and subsequent filling two pipelines is planned within next years; it will enable to extend the presented examinations. Goal of the presented studies is to obtain information about possible displacements and changes in inclination of monolithic bearers of pipelines and their base in static conditions and under influence of the determined changes in loading. This information is indispensable for more deep assessment of safety conditions of particular pressure pipelines. It can be also useful for extending knowledge on way of reacting base of foundations of of constructions located on slopes to changes of loading and in consequence for updating standards which determine permissible displacements.
Zmierzone pionowe przemieszczenia reperów rozmieszczonych na monolitycznym fundamencie służą do wyznaczania parametrów najbardziej prawdopodobnego przemieszczenia fundamentu bez jego deformacji i do obliczenia części przemieszczeń reperów spowodowanych zdeformowaniem fundamentu. Obliczenie następuje na drodze wyznaczenia metodą najmniejszych kwadratów parametrów, przemieszczeń fundamentu na podstawie wszystkich zaobserwowanych reperów. Jeśli w wyniku obliczeń okaże się, że poprawki wyrównawcze zmierzonych przemieszczeń reperów mieszczą się w granicach dokładności pomiarów, to uznaje się praktycznie, że płyta fundamentowa zachowała kształt zgodny z modelem płyty sztywnej. Zdaniem autora w przypadku, gdy dysponujemy informacjami, że w niektórych miejscach podłoże fundamentu jest słabsze (lub mocniejsze) niż w miejscach pozostałych, nie należy opierać wyznaczenia parametrów przemieszczenia fundamentu na wyznaczonych przemieszczeniach wszystkich reperów, lecz należy obliczać parametry z pominięciem reperów zastabilizowanych na fundamencie w miejscach, gdzie podłoże jest słabsze lub mocniejsze. W pracy zilustrowano ten pogląd przykładem wskazującym, że postępowanie takie może znacznie zwiększyć dokładność wyznaczenia parametrów przemieszczeń fundamentu oraz lepiej uwidocznić jego deformacje, które zaszły w strefach słabszego lub silniejszego podłoża.
EN
In order to determine vertical deformations of monolithic surface of foundation plate a set of benchmarks is stabilized at the places agreed with geotechnique and construction specialists. For these benchmarks vertical displacements dH; (or [...] according to notation in the work [Prószyński, Kwaśniak, 2006]) are determined using method of the repeated leveling measurements. Displacement of each benchmark consists of two parts: - [...] part caused by vertical displacement and change of inclination of foundation plate without change of its shape - [...] part caused by vertical deformations of foundation plate at benchmark places. If vertical deformations VdHi of alI benchmarks are within limits of accuracy of differences of dHi displacements, in practice one can assume, that shape of foundation plate was in conformity with the model of stiff plate. Calculation of VdHi value is done through solution of set of observation equations, using method of the least squares. The equations are of the type: [...] where: Xi, Yi - horizontal coordinates of benchmark with i number, [...] - parameters of vertical displacement of foundation plate without change of its shape. In most cases the set of equation to be solved concems dHi observations for all benchmarks stabilized on the foundation. In this work the author justified the assumption, that in case when geotechnique or construction specialist estimated, that base under foundation can be at some places weaker or stronger, which can have impact on local anomalies of -VdHi displacements of benchmarks stabilized in these places, then the measured dHi displacements of these benchmarks should be excluded from calculations of vertical displacement of foundation plate using method of the least squares. According to this assumption -VdHi displacements of benchmarks located in zones of greater deformations of foundation should be calculated later with the use of displacement parameters computed on the basis of solving set of equations solely for these benchmarks, which are outside anomaly zones of foundation. In this work the author included calculation example using data taken from work (Prószyński, Kwaśniak, 2006), which confirms that the proposed procedure is right. This procedure contributes to improvement of determining parameters of displacements of foundation plate, thus revealing in a better way its increased deformations in the appoinwd anomaly zones.
Physicochemical properties of hydroxyapatite [Ca10(OH)2(PO4)6] samples surface were studied and physicochemical quantities characterizing the electrical double layer of the hydroxyapatite/NaClO4 solution interface were determined. The investigated samples were synthesized by two methods. Hydroxyapatite (HAP) was investigated using X-ray diffraction (XRD), X-ray fluorescence (XRF), adsorption-desorption of nitrogen (ASAP), photon correlation spectroscopy (PCS), infrared spectroscopy (IR), and AFM microscope. The surface area, the average volume of pores and the size of particles of hydroxyapatite of the samples were determined. The surface charge density and the potential were studied as a function of pH and the point of zero charge and the isoelectirc point of samples were determined. On the basis of potentiometric titrations the values of surface ionization and complexation constants were calculated.
11
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A study of adsorption of carbonate ions at the interface of ZnO/aqueous solution of NaClO4 is presented. The concentration range of carbonate ions was 1 ⋅ 10-6 to 1 ⋅ 10-3 M. The shape of adsorption of carbonate ions plot vs. pH is characteristic for anions adsorption onto metal oxides and is called the "adsorption envelope". In order to prevent carbon dioxide access to solution, all measurements must have been taken in special chamber in nitrogen atmosphere.
PL
Badania nad adsorpcją jonów węglanowych na granicy faz tlenek cynku/wodny roztwór NaClO4 są przedstawione w niniejszej pracy. Zakres stężenia jonów węglanowych, dla których przeprowadzono pomiary wynosi od 10-6 do 10-3 M. Kształt krzywych adsorpcji względem pH jest charakterystyczny dla adsorpcji anionów na tlenkach metali i jest nazywany "obwiednią" adsorpcji. W celu wyeliminowania dostępu dwutlenku węgla do układu badanego wszystkie pomiary były przeprowadzone w specjalnej komorze.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The study on adsorption of heavy metals (Cd(II), Ni(II) and Pb(II)) at the Al2O3-SiO2/electrolyte solution interface is presented in this paper. The influence of ionic strength, pH, background electrolyte (NaClO4) concentration and composition of metal oxide on adsorption of Cd(II), Ni(II) and Pb(II) from solution of initial concentration ranged from 1×10-6 to 1×10-3 mol/dm3 in the mentioned system was investigated. The adsorptions edge parameters (pH50% and pH10-90%) for different concentrations of electrolyte were presented. The adsorption measurements were complemented by the potentiometric titration of Al2O3-SiO2 suspensions and electrophoretic measurements. Charge reversal point (CR2) can be observed for solution concentration of 10-3 mol/dm3 as a result of Cd(II), Ni(II) and Pb(II) ions adsorption.
PL
Kadm, ołów i nikiel są toksycznymi metalami ciężkim, który stanowią wciąż poważne zagrożenie dla organizmów żywych. W środowisku naturalnym oraz w wielu procesach technologicznych mamy do czynienia ze skomplikowanymi układami gdzie występują obok siebie tlenki typu Al2O3-SiO2 oraz jony metali ciężkich. Przeprowadzono badania adsorpcji jonów niklu, kadmu i ołowiu dla różnych stężeń początkowych, w funkcji pH dla układów AS1, AS3, AS8/roztwór NaCl. Kształt krzywych adsorpcji w funkcji pH ma postać krawędzi adsorpcji. Wzrost stężenia początkowego jonów metali ciężkich, powoduje przesunięcie krawędzi w kierunku zasadowym skali pH. Wyznaczono charakterystyczne parametry krawędzi adsorpcji tj. pH50% i apH10-90%, w oparciu o zależność adsorpcji od pH stosując model TLM, obliczono równieS stałe reakcji adsorpcji jonów Ni(II), Cd(II), Pb(II) metodą optymalizacji numerycznej. Zależność gęstości ładunku powierzchniowego od pH w obecności jonów metali ciężkich, jest w dobrej korelacji z zależnością adsorpcji jonów Ni(II), Cd(II), Pb(II) od pH. Adsorpcja badanych jonów na powierzchni AS1, AS3, AS8 prowadzi do wzrostu stężenia grup ujemnie naładowanych.
Przedmiotem rozważań jest sposób przeprowadzenia uzupełniających obliczeń dotyczących pomiarów przemieszczeń punktów i reperów rozmieszczonych na i w budowli oraz wnioski wypływające z wyników tych obliczeń. W większości przypadków geodezyjny monitoring przemieszczeń kończy się na pomierzeniu i obliczeniu przemieszczeń punktów rozmieszczonych na i w budowli, natomiast w niniejszej pracy wyznaczone przemieszczenia punktów, traktowane dalej jako pseudoobserwacje, poddane zostały dodatkowym przeliczeniom prowadzącym do wyznaczenia parametrów przemieszczeń całej budowli lub jej określonych fragmentów. Umożliwia to zauważenie, jak zachowywała się budowla, a nie tylko jak zachowały się rozmieszczone na niej punkty geodezyjne. Takie dodatkowe przeliczenia i analiza ich wyników są elementem geometrycznej interpretacji wyników pomiarów, dokonywanej przez geodetę prowadzącego monitoring, która ułatwia projektantom dokonywanie przyczynowo-skutkowej interpretacji wyników pomiarów. Dokonywanie interpretacji geometrycznej należy traktować jako ,,pomost" w porozumieniu specjalistów zajmujących się z różnych pozycji monitorowaniem bezpieczeństwa pracy wznoszonych i eksploatowanych obiektów budowlanych. Służy to polepszeniu i pogłębieniu oceny wyników wykonanych pomiarów w procesie wykrywania przyczyn określonego zachowania się budowli i ich podłoża. W niniejszej pracy poddano dodatkowej analizie przemieszczenia poziome 4 punktów i przemieszczenia pionowe 24 reperów rozmieszczonych na żelbetowej budowli wodnej. Przemieszczenia te nastąpiły pod wpływem opróżnienia przyległego do budowli zbiornika wodnego oraz podwyższenia temperatury powietrza.
EN
Method of conducting supplementary computations, concerning measurements of displacements of points and benchmarks located on the construction and inside it, was the scope of the presented work, as well conclusions derived from the results of computations. In most cases geodetic monitoring of displacements is completed, when displacements of points located on the construction and inside it are measured and computed. In the presented work the determined displacements of points, further treated as pseudo-observations, were used for additional calculations, aimed at determination of parameters of displacements of the whole construction or its particular fragments. This approach enables to observe behavior of the construction itself not only of the geodetic points, which were located on it. Such supplementary calculations and analysis of their results are the element of geometric interpretation of the results of measurements, which is done by surveyor responsible for monitoring and can help designers in making causal-consecutive interpretation of the measurements. Geometrical interpretation should be treated as a "bridge " between specialists dealing with various aspects of monitoring of safety of built and exploited constructions. It helps in improving evaluation of the results of measurements in the process of detecting causes of specific behavior of constructions and their foundations. Horizontal displacements of 4 points and vertical displacements of 24 benchmarks located on ferroconcrete water construction were additionally analyzed in the presented work. These displacements occurred due to emptying the adjoining water reservoir and due to increase of air temperature.
Interaction of silica, alumina/silica and titania/silica nanooxideswith poly(vinyl alcohol) was investigated in gaseous and aqueous media using infrared spectroscopy, adsorption, AFM and photon correlation spectroscopy methods. Formation of PVA monolayer on oxide nanoparticles leads to relatively small changes in morphological and textural characteristics of the materials. The characteristics of interfacial water/PVA layer, particle size distribution and Cd(II) adsorption depend on surface content of alumina or titania affecting amounts of Brönsted and Lewis acid sites. Arelativelyweak influence of various pretreatments on the structural characteristics of the materials depicts the stability of PVA/nanooxide composites as dry powders and aqueous dispersions.
15
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W pracy przedstawiono metodę obliczania przemieszczeń i deformacji fundamentu na podstawie pomierzonych osiadań zespołu zastabilizowanych na nim reperów kontrolowanych. Przyjęto założenie, że duże różnice osiadań reperów położonych w małych wzajemnych odległościach mogą być symptomem podzielenia fundamentu na odrębne monolityczne części i omówiono metodykę obliczania przemieszczeń każdej z nich względem jednolitego układu odniesienia i względem siebie oraz metodykę obliczania zmian kształtu każdej z tych monolitycznych części. Metodykę obliczeń zilustrowano na trzech przykładach.
EN
Method of calculating displacements and deformations of foundations on the basis of the measured settlements (vertical displacements dH) of stabilized benchmarks, was presented in the article. In case, when foundation consists of individual monolithic fragments, separated by expansion gaps or divided due to deep cracks, the analysis aimed at identification of these fragments is done. For this purpose the following procedure is applied: 3 parameters of displacements of each potentially undisturbed fragment are calculated for many benchmark combinations, i.e. its changes of inclination [...], [...] along axes of orthogonal system of horizontal coordinates x, y and vertical displacement at the center of coordinate system dHo. Moreover, the check is done, which fragments of foundations do not reveal vertical deformations [...] in places, where benchmarks were stabilized. Fragments of foundation, which do not reveal vertical deformations greater than errors of their determination, are recognized as undisturbed, i.e. monolithic. Fragments slightly disturbed - within their limits of elasticity are also recognized as monolithic. Next, on the basis of the determined parameters of displacements of monolithic fragments of foundations mutual displacements in the zones of cracks are calculated, as well as differences of angles and horizontal inclinations of these fragments are computed. The method enables to identify, on the basis of the measured bench mark settlements, cracks of foundation, which cause its division into separate, monolithic parts, even in cases when other symptoms of such a division are not visible (for instance when division is caused by many tiny cracks, which do not appear as deep cracks, separating monolithic, undisturbed parts of foundation).
Unmodified and modified nanosilicas containing different content of trimethylsilyl (TMS) groups grafted by interaction with various amounts of hexamethyldisilazane (HMDS) in a reactor contacting with air were studied using infrared spectroscopy, adsorption and potentiometric titration methods. Contribution of narrow gaps between spherical primary silica particles forming aggre gates decreases with in creasing TMS loading (tetaTMS), because of blocking of these gaps by grafted functionalities. Contribution of broader gaps corresponding to mesopores de ends slightly on tetaTMS, and changes in contribution of macropores are rather random. IR spectra of modified samples depict changes in bands of the O-H stretch ingvibrations at 3750 and 3300 cm-1 (reduced with qTMS) and 3680 and 3500 cm-1 (changed nonlinearly with qTMS), since HMDS can interact with silanols and ad sorbed water and af fect the ad sorbed amounts of water. Enhance ment of the hydrophobic properties of the surface reduces the amounts of adsorbed water, and the IR band in tensity at 3300 cm-1 di minishes. The adsorption of poly(vinyl pyrrolidone) on silicas decreases with tetaTMS in consequence of changes in the surface structure and the reduction of adsorption potential. The silylation diminishes the su face charge density and the electrostatic surface poten tial, and the point of zero charge shifts to ward larger pH values with in creasing tetaTMS value.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Opisano konstrukcję zaprojektowanego i wykonanego w Instytucie Geodezji i Kartografii komparatora łat kodowych z użyciem niwelatorów cyfrowych w wersji "nieruchomy niwelator cyfrowy - ruchoma łata kodowa", omówiono wyniki badań porównawczych komparatorów oraz wyniki wstępnego badania zestawów niwelatorów cyfrowych DiNi 11, DiNi 12 firmy Zeiss i łat kodowych LD 13, niwelatorów cyfrowych NA3000, NA 3003 firmy Leica i łat kodowych GPCL 2, GPCL 3 oraz łaty kodowej i niwelatora cyfrowego DL101-C firmy Topcon.
EN
Calibration of code staffs should be done with the use of laser interferometer and digital level, which is utilized for field measurements applying the calibrated staffs, as not only staff graduation is checked, but ability of self-dependent, correct measurements and conversion to metric system by leveling instrument is also verified. Calibration can be done on comparator in version "movable digital level - fixed code staff", constructed at the Institute of Geodesy and Cartography in Warsaw in March 2003, when there was no adequately high laboratory to move staffs vertically. Such a comparator was described in IGiK Proceedings (J. Janusz, W. Janusz, M. Kolodziejczyk, 2003a,b). In January 2004, at new laboratory, which enables to move staffs vertically, new comparator in version "fixed digital level movable code staff" was constructed at the Institute of Geodesy and Cartography. Construction of this comparator and results of comparative examinations of both versions were described in the presented work. It was found, that using comparator in version "fixed digital level movable code staff" it is possible to obtain higher precision of calibration, because level's readouts are not affected with changes of comparator position and with variable refraction distortions of axis of collimation, while aiming telescope at different levels. The results of calibration for the following code staffs were discussed: - 8 LD 13 code staffs with the use of Zeiss DiNi 11 and DiNi 12 digital levels; - 2 GPCL2 code staffs and 2 GPPCL3 code staff s with the use of Leica NA 3003 digital level, as well as 2 GPCL2 code staffs using Leica NA 3000 digital level; - one code staff with the use of Topcon DL 101-C digital level. It was found, that readouts on staffs can be done with mean errors 3-7 [...]m, while A coefficient of systematic error can be determined with mean error mA = 1 - 3 [...]m/m. At the same time it was found, that A coefficient, which characterizes deviation of the average meter of graduation, did not exceed for all checked staffs 15 [...]m/m, although some of these staffs were intensively exploited for about 7 years. In the course of examination of LD 13 staffs with the use of DiNi 11 level it was found, that staff graduation can be affected locally with great errors, around 0,2 mm, while aiming at fragment of graduation, which is permanently damaged by its scratching or uncleanness. Some examples were given, how to determine on comparator with the use of digital level those fragments of staff graduation around damages, which should not be taken for readouts.