W pracy poruszono tematykę wyznaczania parcia mieszanki betonowej na deskowanie. Zebrano i opisano wybrane cztery modele stosowane do wyznaczania rozkładu ciśnienia poziomego świeżej mieszanki betonowej oddziaływującej na deskowanie. Dokonano krótkiego przeglądu literatury z zakresu omawianej tematyki parcia mieszanki betonowej na deskowanie.
EN
The paper addresses determining the pressure of the fresh concrete mix on the formwork. Selected four models used to determine the horizontal pressure distribution of fresh concrete mix acting on the formwork are collected and described. A short review of the literature on the subject of concrete mix pressure on the formwork is presented.
W niniejszej pracy dokonano przeglądu literatury z zakresu mieszanek i zapraw betonowych stosowanych w druku trójwymiarowym. Przegląd literatury przygotowano z zachowaniem chronologii pojawienia się danej publikacji (daty publikacji). Na podstawie przeprowadzonego przeglądu dokonano tabelarycznego zestawienia receptur mieszanek wykorzystywanych w wydrukach trójwymiarowych (3D). Przedstawiony przegląd literatury z zakresu mieszanek i zapraw betonowych stosowanych w druku trójwymiarowym można traktować jako wstęp do szczegółowych badań związanych z projektowaniem nowych typów mieszanek i receptur.
EN
This paper presented a state-of-the-art review of the literature on the subject of concrete mixes and mortars used in 3D (three-dimensional) printable concrete. The literature review is prepared by the chronology of the publication (date of publication). Based on the performed state-of-the-art review, a tabular list of concrete mix recipes used in three-dimensional printing technology is given. The presented literature review in the field of concrete mixtures and mortars used in three-dimensional printing can be treated as an introduction to detailed research related to the design of new types of mixtures.
This research aims to determine the influence of water-soaking on polyester-based coated woven fabrics for ultimate tensile strength and elongation at break under uniaxial tensile tests. The paper begins with a short survey of literature concerning the investigation of the determination of coated woven fabric properties. The authors carried out the uniaxial tensile tests with an application of a flat grip to establish the values of the ultimate tensile strength of groups of specimens treated with different moisture conditions. SEM fractography is performed to determine the cross-section structures of coated woven fabrics. The change in the mechanical properties caused by the influence of water immersion has not been noticed in the performed investigations.
PL
Niniejsze badania mają na celu określenie wpływu nasiąkania wodą na poliestrowe tkaniny powlekane na wytrzymałość na rozciąganie i wydłużenie przy zerwaniu w próbach jednoosiowego rozciągania. Artykuł rozpoczyna się od krótkiego przeglądu literatury dotyczącej badań nad właściwościami tkanin technicznych. Autorzy przeprowadzili próby rozciągania jednoosiowego z użyciem szczęk płaskich w celu wyznaczenia wartości wytrzymałości na rozciąganie grup próbek poddanych działaniu różnych warunków wilgotnościowych. Wykonano także fraktografie SEM w celu określenia struktury przekrojowej tkanin powlekanych. W przeprowadzonych badaniach nie zauważono zmiany właściwości mechanicznych pod wpływem zanurzenia w wodzie.
This research aims to determine the influence of the cyclic process of freezing and defrosting on the mechanical properties of the chosen glass fibres and PTFE-coated woven fabrics. The specimens were subjected to freezing at about -20°C for 4 h and thawing by full immersion into the water at about +20°C for 4 h. The fabric samples after 25 and 50 frozen cycles were air-dried at room temperature for one week and then subjected to uniaxial tensile tests. The same tests have been performed on a reference group of specimens, which were not exposed to temperature change. The authors determined the tensile strength, and longitudinal stiffnesses resulting from performed tests. Although the investigated coated woven fabrics expressed a reduction in the tensile strength in water soaking conditions, the performed frozen cycles don’t show a significant decrease in strength under uniaxial tensile tests.
PL
Artykuł opisuje badania tkanin technicznych wykonanych z włókana szklanego i powlekanych politertafluroetylenem (PTFE) (ang. PTFE-coated woven fabric), które mają na celu określenie wpływu cyklicznych procesów zamrażania i rozmrażania na właściwości mechaniczne wybranych tkanin Próbki tkanin technicznych zostały poddane zamrażaniu w temperaturze około -20°C przez 4 godziny i rozmrażaniu przez całkowite zanurzenie w wodzie w temperaturze około +20°C przez 4 godziny. Próbki tkanin technicznych po 25 i 50 cyklach zamrażania suszono na powietrzu w temperaturze pokojowej przez tydzień, a następnie poddano próbom jednoosiowego rozciągania. Na podstawie testów jednoosiowego rozciągania określono wytrzymałość na rozciąganie i moduły sztywności. Pomimo, iż w badanych tkaninach powlekanych następuje spadek wytrzymałości na rozciąganie w warunkach ich namoczenia w wodzie, to wykonane cykle zamrażania nie wykazują znacznego spadku wytrzymałości w próbach jednoosiowego rozciągania.
W pracy poruszono tematykę wykorzystania analizy przepływu CFD do wyznaczenia obciążeń wiatrem dla budynku wysokiego o złożonej geometrii przestrzennej. Przedstawione wyniki obliczeń analitycznych dla budynku wysokiego porównano z wynikami obliczeń numerycznych wykonanych w programie R-Wind Simulation. Dokonano analizy optymalizacji geometrycznej kształtu budynku w zakresie wpływu kąta skrętu (modyfikacja typu makro) i zaokrąglenia/fazowania narożników (modyfikacja typu mikro) na wypadkowe siły od obciążenia wiatrem oraz na aerodynamiczne współczynniki sił. Całość wyników podsumowano i sformułowano wnioski w odniesieniu do wyznaczania wielkości obciążenia wiatru działającego na budynek wysoki.
EN
The paper addresses the use of CFD flow analysis to determine wind loads for a tall building with complex spatial geometry. The presented results of analytical calculations for a tall building were compared with the results of numerical calculations performed in the R-Wind Simulation program. The geometric optimization of the building shape was analyzed in terms of the influence of the turning angle (macro-type modification) and corner rounding (micro-type modification) on the resultant forces from wind loads and on the aerodynamic force coefficients. All the results were summarized and conclusions were formulated concerning wind load acting on a tall building with complex geometry.
W pracy poruszono tematykę wykorzystania analizy przepływu CFD do wyznaczania obciążeń wiatru na konstrukcje. Przedstawiono analizę trzech modeli budynków o dachu dwuspadowym o różnych kątach nachylenia, dla których dokonano porównania wielkości współczynników parcia z wynikami dostępnymi w literaturze. Obliczenia analityczne wykonano zgodnie z normą z PN-EN 1991-1-4, natomiast obliczenia numeryczne wykonano w programie R-Wind Simulation. Całość wyników podsumowano, a wnioski sformułowano w odniesieniu do tematyki rozwiązania problemu szacowania wielkości obciążenia wiatru działającego na konstrukcję.
EN
The paper addresses the use of CFD flow analysis to determine wind loads on structures. Three models of buildings with a gable roof with different angles of inclination were presented, for which the size of the pressure coefficients was compared with the results available in the literature. The analytical calculations were made in accordance with the PN-EN 1991-1-4 standard, while the numerical calculations were made in the R-Wind Simulation program. All the results were summarized and the conclusions were formulated in relation to the problem of solving the problem of estimating the size of the wind load acting on the structure.
The proposition of a method to verify the punching resistance for very large supports based on the EN 1992-1-1 standard is described in this paper. The present standard guidelines for the calculation of the punching resistance for large supports are also summarised. The proposed direct method is compared with other standard methods using an example taken from design practice. This method consists of a direct check of the shear forces at specific locations of the control perimeter with the permissible shear force calculated from the EC2 standard. The method showed very good agreement with the experiment while remaining practical for applications. The method presented takes into account the actual distribution of shear forces in the vicinity of the support, taking into account the influence of non-uniform loads, irregular floor geometry, the concentration of internal forces at the corners of the support and the influence of the stiffness of the head used. The paper provides scientists, engineers, and designers new method (called the direct method) for estimation of the punching load-bearing capacity outside the shear cap.
PL
W artykule omówiono propozycję metody weryfikacji nośność na przebicie dużych podpór w oparciu o normę EN 1992-1-1. Przedstawiona metoda uwzględnia rzeczywisty rozkład sił ścinających w sąsiedztwie podpory z uwzględnieniem wpływu obciążeń niejednorodnych, nieregularnej geometrii stropu, koncentracji sił wewnętrznych w narożach podpory oraz wpływu zastosowana sztywność głowy. Jest to kolejna zaleta proponowanej metody w porównaniu z normowymi metodami obliczania nośności na przebicie poza głowicami w połączeniu płyta-słup. Podsumowano wybrane aktualne normowe wytyczne dotyczące obliczania nośność na przebicie dla bardzo dużych podpór. Zaproponowaną metodę porównano z wybranymi normowymi metodami na przykładzie zaczerpniętym z praktyki projektowej. Autorzy niniejszej pracy mają nadzieję, że proponowana metoda będzie pomocna projektantom konstrukcji w ocenie rzeczywistej wytrzymałości na przebicie połączeń płyta-słup zwieńczonych głowicą. Metoda wykazała bardzo dobrą zgodność z przeprowadzonymi eksperymentami. Niemniej jednak wydaje się konieczne przeprowadzenie większej liczby badań laboratoryjnych w celu wykazania uniwersalności proponowanego podejścia. Opisana metoda bezpośrednia winna wzbudzić w środowisku inżynierów budownictwa i naukowców żywe zainteresowanie, które będzie polem do dyskusji i podjęcia tematu wyznaczania nośności na przebicie.
W pracy poruszono tematykę analizy obudowy wykopu dla budynku z jedną kondygnacją podziemną, zlokalizowanego w gęstej zabudowie śródmiejskiej. Obliczenia przeprowadzono za pomocą dwóch programów obliczeniowych: GEO 5 (moduł: Ściana Analiza) i Autodesk Robot Structural Analysis Professional. Całość wyników podsumowano, a wnioski sformułowano w odniesieniu do obecnej sytuacji na rynku budowlanym, charakteryzującej się coraz to trudniejszymi warunkami gruntowymi, gęstszą zabudową śródmiejską oraz trudniejszym ukształtowaniem terenu.
EN
The paper addresses excavation shoring analysis for a building with one underground storey, located in high-density urban development. The paper focuses on available computational methods, vital design assumptions and reduction of the impact of structural works on adjacent buildings sensitive to ground motion. Computations have been conducted and compared in two software variants: GEO 5 (Excavation Design module) and Autodesk Robot Structural Analysis Professional. The results are summarized and conclusions are drawn with regard to the current construction industry status. The latter is characterized by increasingly difficult ground conditions, high-density urban development and demanding terrain topography.
9
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The joining process of bainitic rails is significant in terms of their industrialization in high-speed and heavy-loaded railways. This paper demonstrates the microstructure changes in the critical zone of the welded joint, which is responsible for the greatest deterioration in mechanical properties. Extensive progress in the decomposition of the retained austenite and bainitic ferrite occurs in the low-temperature heat-affected zone (LTHAZ) of the flash-butt welded joint of low-carbon bainitic rail. The decomposition products of the retained austenite were mainly a mixture of cementite and ferrite. The cementite was mainly precipitated at the boundary of the bainitic ferrite laths, which indicates lower thermal stability of the filmy austenite. Moreover, it was found that a part of the refined blocky retained austenite was decomposed into the ferrite and nanometric cementite, while another remained in the structure. The decomposition mechanisms are rather heterogeneous with varying degrees of decomposition. A relatively high proportion of dislocations and stress fields prove the occurrence of residual stresses formed during the welding process.
Plasma sprayed ceramic coatings serve as protective layers and are frequently exposed to aggressive wear, corrosion, or high-temperature environment. Currently, alumina and alumina-titania are some of the most popular protective ceramic composite coatings used in the industry. The present work deals with the investigation of the influence of TiO₂ content in the feedstock powder on the resulting microstructure and properties of Al₂O₃, Al₂O₃ + 3 wt% TiO₂, Al₂O₃ + 13 wt% TiO₂ and Al₂O₃ + 40 wt% TiO₂ coatings developed via atmospheric plasma spraying (APS). Specifically, the phase composition, morphology, and microstructure, as well as the mechanical and tribological performance of the coatings were examined. Results revealed that higher content of TiO₂ induced the transformation of phases, leading to the formation of intermediary Al₂TiO₅ and Al₂- xTi₁- xO₅ phases. Also, the dominant α–Al₂O₃ to γ–Al₂O₃ transformation confirmed the formulation of well-melted lamellas within the coating structure. It was also shown that the increase in TiO₂ content decreased the micro-hardness of the coatings due to the formation of the intermediary phases as mentioned above and thus, affected their tribological performance. The lowest volumetric wear, equal to 7.2×10⁻⁵ mm³/(N ∙ m), was reported for Al₂O₃ + 13 wt% TiO₂ coating.
The aim of the research is the laboratory investigation of steel-aluminium brackets employed to fasten lightweight curtain walls to building facilities. Static pressure, suction forces, and cyclic loads parallel to end plates (horizontal - to simulate wind influence) were applied in the study. The steel-aluminium brackets were tested on a reinforced concrete substrate made of C30/37 concrete class to simulate the real working conditions. Laboratory tests were performed to failure of the brackets or damage of anchoring fastened to the concrete elements. Additionally, the tensile capacity of stainless steel bolt connections screwed in aluminium profile was determined. The uniaxial tensile tests were performed for three length variants of the anchorage: 28 mm, 14 mm, and 7 mm of the stainless steel bars screw-in in threading aluminium profiles. In the course of cyclic tests, a hinge formed in the location of bolt connections made the change of the working character of steel-aluminium brackets. The cyclic tests also showed the danger of the strap aluminium profile displacement due to improper connection with the main aluminium profile. The paper is intended to provide scientists, civil engineers, and designers with an experimental assessment of mechanical properties of steel-aluminium brackets under static and cyclic loads.
PL
Przedmiotem przedstawionych w artykule badań laboratoryjnych są konsole stalowo-aluminiowe, które są stosowane jako elementy łącznikowe fasad słupowo-ryglowych z konstrukcją budynku. Blacha podstawy konsoli wykonana jest ze stali S355, która jest połączona z profilem aluminiowym ze stopu aluminium EN AW-6060 T66 [7] trzema nierdzewnymi śrubami A2-70 M8x35 (DIN 7991). Pomiędzy blachą podstawy a profilem aluminiowym zastosowana jest przekładka z EPDM-u. Konsole stalowo-aluminiowe poddawane były statycznym próbom obciążenia siłami parcia i ssania, które symulowały obciążenia wiatrem. Konsola w trakcie badań zamocowana była do elementów żelbetowych wykonanych z betonu C30/37 dwoma kotwami sworzniowymi M10 z kontrolowanym momentem dokręcenia. Wyznaczone siły niszczące dla obciążeń pochodzących od parcia (21.6 +/- 0.9 kN) i ssania (-22.3 +/- 0.7 kN) mają podobne wartości, przy czym o nośności konsoli na obciążenia pochodzące od ssania decydowała nośność zakotwienia (które uległo zniszczeniu przy tym poziomie obciążenia). Oprócz badań statycznych przeprowadzono badania cykliczne, w których obciążenie przykładane było naprzemiennie jako parcie i ssanie dla następujących poziomów obciążenia: L1 (+5/-5 kN), L2 (+10/-10 kN), L3 (+15/-15 kN), L4 (+20/-20 kN). Dla każdego poziomu obciążenia konsole poddawane były 50 cyklom obciążenia. Trzy z badanych konsol uległy zniszczeniu podczas badań cyklicznych przy poziomie L3 oraz dwie konsole przy przekroczeniu obciążenia +15 kN (początek poziomu L4). Na podstawie badań cyklicznych stwierdzono możliwość wysuwania się dolnego profili aluminiowego, który jest dołączany do głównego profilu za pomocą dwóch wkrętów. W celu wyeliminowania przemieszczania się dolnego profilu zalecono połączenie trzema blachowkrętami samowiercącymi z łebkiem walcowym ze stali nierdzewnej 5.5x3.8 (DIN7504N). Przeprowadzone badania wytrzymałościowe potwierdziły możliwość przeniesienia projektowanych obciążeń w zakresie +5 ÷ -5 kN. Jednym z elementów decydujących o nośności konsoli stalowo-aluminiowej jest nośność połączenia wkręconych w nagwintowany profil aluminiowy śrub M8. W celu oszacowania nośności tego połączenia wykonano testy jednoosiowego rozciągania połączenia pręta M8 wkręcanego w nagwintowany profil aluminiowy na określone długości (28 mm, 14 mm i 7 mm). Nośność tego połącznia jest proporcjonalna do długości wkręcania pręta/śruby w profil aluminiowy. Oszacowania na tej podstawie nośność konsoli jest wyższa niż otrzymana na podstawie badań wytrzymałościowych. Wynika to z faktu, iż na połączenie śrubowe oddziaływają nie tylko obciążenia rozciągające, ale także ścinające i zginające.
This research aimed to investigate the water vapour transmission properties of chosen EPDM membranes applied in façade and window systems under laboratory tests. The applied procedure included in national and international standards utilized for the laboratory tests of water vapour transmission properties of EPDM membrane is described. Two main types (outside and inside types) of EPDM membranes are laboratory tested. The authors indicated that the EPDM membranes should differ in surface factures. Nevertheless, some manufacturers mark EPDM membranes on each roll (on the package only) without different permanent denotations on the EPDM membranes surfaces. This form of denotations can cause using problems - using the wrong types of the EPDM aprons in building partitions, because when the package is removed there is impossible to visually identify the type of EPDM membrane (outside or inside type) from the texture of the membrane surface. The experimental results of laboratory tests indicated using the wrong type of EPDM membrane in the inside aprons in building partitions in the investigated façade window system. The designed proportion of the sd values (the resistance to movement of water vapour) of inside and out-side EPDM façade membranes should be designed equally to about 3.0 (recommended value 4) to provide proper diffusion properties of partitions around windows in façade systems. The paper can provide scientists, engineers, and designers an experimental basis in the field of the EPDM membranes water vapour transmission properties applied to façades and windows systems.
PL
Celem badań było określenie właściwości przepuszczalności pary wodnej wybranych membran elewacyjnych EPDM stosowanych w systemach fasadowych i okiennych w ramach testów laboratoryjnych. Omówiono zastosowaną procedurę zawartą w normach krajowych i międzynarodowych stosowanych do badań laboratoryjnych właściwości przepuszczalności pary wodnej membrany EPDM. Dwa główne typy (zewnętrzne i wewnętrzne) membran EPDM zostały poddane badaniom laboratoryjnym. Proces określania właściwości przepuszczalności pary wodnej dla membran EPDM jest długotrwałym badaniem laboratoryjnym. Projektowana proporcja wartości sd (oporu na ruch pary wodnej) wewnętrznych i zewnętrznych membran elewacyjnych EPDM powinna być równa około 3,0 (zalecana wartość 4), aby zapewnić odpowiednie właściwości dyfuzyjne przegród wokół okien w systemach elewacyjnych. Eksperymentalne wyniki badań laboratoryjnych wskazały na zastosowanie niewłaściwego rodzaju membrany EPDM w fartuchach wewnętrznych przegród budowlanych w badanym systemie okien fasadowych. Autorzy mają nadzieję, że opisane testy laboratoryjne wzbudzą żywe zainteresowanie środowiska inżynierów i naukowców, aby uwzględnić tematykę właściwości przepuszczalności pary wodnej membran EPDM stosowanych w systemach elewacjach i okiennych.
The paper presents the results of qualitative tests of Cu-Al joints made by soldering, brazing and resistance welding. Aluminum and copper tubes with a diameter of 6.9 mm, used, among others in refrigeration systems, were soldered with ZnAl2 and AlSi12 filler metal. In addition, similar connections were made by resistance welding. Macroscopic tests of soldered and welded joints were carried out and the hardness distribution on the cross-section of joints was determined. The analysis of research results allowed to state that resistance welding of Cu-Al joints can be a good alternative to the soldering process, especially in series production, due to the possibility of easy application of process mechanization.
PL
W pracy zamieszczono wyniki badań jakościowych złączy Cu-Al wykonanych metodami lutowania twardego i miękkiego oraz zgrzewania oporowego zwarciowego. Rurki aluminiowe i miedziane o średnicy 6,9 mm, stosowane m. in. w układach systemów chłodniczych lutowano spoiwem ZnAl2 oraz AlSi12. Ponadto wykonano podobne połączenia metodą zgrzewania oporowego. Przeprowadzono badania makroskopowe złączy lutowanych i zgrzewanych oraz określono rozkład twardości na przekroju złączy. Przeprowadzona analiza wyników badań pozwoliła na stwierdzenie, że zgrzewanie oporowe złączy Cu-Al może być dobrą alternatywą dla procesu lutowania zwłaszcza w produkcji seryjnej, z uwagi na możliwość łatwego zastosowania mechanizacji procesu.
W pracy poruszono tematykę analizy numerycznej i wymiarowania stropu kablobetonowego. Przedstawiono przykład obliczeniowy, w którym omówiono poszczególne etapy budowy modelu numerycznego w programie SOFiSTiK oraz wymiarowania stropu żelbetowego kablobetonowego budynku biurowo-usługowego zaprojektowanego w układzie płytowo-słupowym.
EN
The subject of numerical analysis and designing of a cable-prestressed concrete ceiling is discussed in the paper. A computational example is presented in which the individual stages of building a numerical model in the SOFiSTiK program and designing of the reinforced concrete cable-prestressed ceiling of an office and service building designed in a slab-pillar system are discussed.
W pracy poruszono problem obliczania przekrycia żelbetowego w kształcie powłoki synklastycznej ściętej o podstawie kwadratowej. Przedstawiono obliczenia analityczne i numeryczne sił w powłoce. Powłoka jest poddana działaniu głównie sił ściskających, co jest korzystne dla tego typu konstrukcji. W strefie brzegowej i podporowej konieczne jest wymiarowanie na mimośrodowe ściskanie i rozciąganie z uwagi na znaczący wzrost momentów zginających.
EN
The problem of calculating reinforced concrete covering in the shape of a synclastic shear shell with a square base is discussed in the paper. Analytical and numerical calculations of forces in the shell are presented. The coating is mainly subjected to compressive forces, which is beneficial for this type of construction. In the boundary and support zones, it is necessary to calculate for eccentric compression and tension due to the significant increase in bending moments.
16
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents problems related to the regeneration of wheel hubs for mining machinery vehicles carried out with arc welding using the MAG method. Hubs made of medium-carbon cast steel, type LII500, were weld surfaced with filler metal grade of G4Si. The tests were aimed at determining welding imperfections and metallographic properties of the surfacing welds. The influence of heat treatment on the properties of surfacing was investigated. Hardness distributions in welded hubs after various heat treatment operations were determined. Recommendations for the technology of weld surfacing the wheel hubs were formulated.
PL
W pracy przedstawiono problemy związane z regeneracją piast kół pojazdów maszyn górniczych realizowanych napawaniem łukowym metodą MAG. Piasty wykonane ze staliwa średnio węglowego gat. LII500 napawano spoiwem gat. G4Si1. Badania miały na celu określenie niezgodności spawalniczych oraz właściwości metalograficznych napoiny. Zbadano wpływ obróbki cieplnej na właściwości napoiny. Określono rozkłady twardości w napawanych piastach po różnych zabiegach obróbki cieplnej. Sformułowano zalecenia do technologii napawania piast.
Atmospheric Plasma Spraying (APS) enables deposition of coatings from different materials, including those based on Al2O3 and TiO2. In this work, Al2O3 + 40 wt.% TiO2 coatings were tested. The relationships between mechanical properties, microstructure and spraying parameters (namely: spraying distance and torch scan velocity) were investigated. Commercial -45 + 5 μm powders in agglomerated as-produced state were sprayed onto the stainless steel 1.4301 substrates. The aim of the study was to determine the adhesion, microhardness and roughness of coatings but also to characterize their microstructure. It was observed that coatings sprayed from shorter distance were well melted and revealed good adhesion, but at the same time they were more porous and of lower microhardness than those deposited from the longer spraying distance.
PL
Metoda natryskiwania plazmowego, APS (ang. Atmospheric Plasma Spraying) umożliwia nanoszenie powłok z różnych materiałów, w tym na bazie Al2O3 oraz TiO2. W pracy zbadano powłoki Al2O3 + 40% wag. TiO2. Przedmiotem badań były właściwości mechaniczne oraz mikrostruktura uzyskanych powłok, w zależności od odległości natryskiwania i prędkości przesuwu palnika względem podłoża. Wykorzystano komercyjne proszki w stanie aglomerowanym o granulacji -45 + 5 μm, którymi pokryto podłoża ze stali nierdzewnej 1.4301. Przeprowadzone badania miały na celu określenie przyczepności powłok, ich mikrotwardości, chropowatości oraz charakteryzację mikrostruktury. Zaobserwowano, że krótsza odległość natryskiwania skutkuje wyższym stopniem przetopienia cząsteczek proszku w powłoce oraz wyższą przyczepnością powłok, ale jednocześnie powoduje wyższą porowatość i niższą mikrotwardość powłok.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono analizę porównawczą wybranych metod przykładania obciążenia zmiennego na konstrukcję płytowo-słupową. Przeanalizowano pięć sposobów rozkładu obciążenia na płytę stropową. Wyniki momentów zginających i przemieszczeń w wybranych punktach porównywano z wartościami ekstremalnymi obliczonymi na podstawie powierzchni wpływu (Wariant 1). Wykonane obliczenia pozwoliły na wskazanie zalecanej metody rozkładu obciążenia zmiennego na płytę stropową w konstrukcji płyta-słup.
EN
The article compares selected methods of live load application to slab-column structures. Five variants of live load distribution on a plane slab are analysed here. The analysis results for the investigated cases are bending moments and displacements at selected points, compared with the extreme values computed by means of influence areas (Variant 1). The calculations made it possible to indicate the recommended method of live load distribution on a flat slab in slab-column structures.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule opisano zakres badań polowych niezbędnych do określenia poziomu drgań w budynku biurowo-usługowym podczas pracy agregatu prądotwórczego zlokalizowanego na dachu tego budynku. Dokonano oceny szkodliwości pomierzonych drgań na budynek i ludzi, którzy się w nim znajdują. Przedstawiono także krótki przegląd literatury dotyczącej oceny szkodliwości oddziaływań dynamicznych na budynki lub ludzi.
EN
All necessary tests carried out to measure a level of dynamic vibrations in office-service building during working of power generator on building roof are described. The evaluation of the harmfulness of buildings vibrations and influence on humans in buildings is performed. In addition, a short literature review of dynamic vibrations assessment on building and people is presented.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.