Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Amplitude and frequency content are two important features of earthquakes that are different for near and far-fault earthquakes and in most of the standards, the effects of near-field earthquakes in loading are not considered. Therefore, study and comparison of these effects on structures is necessary. In this paper, structural operation against near and far fault earthquakes for two near sites and two far sites is investigated. For this purpose and in order to achieve an operation point of a structural model with six staircases with a mean lateral bending frame resistant system seismic hazard information is analyzed with regards to special plan spectrums of 2 different sites using near and far faults. An evaluation of the effects due to near and far fault earthquakes based on the Iran’s standard 2800 ranges on operation point and the comparison of operation effects of near and far fault spectrums with Iran’s standard are results of this research work. After the presentation of results obtained from time history analyses, some suggestions are proposed for design correction based on the regulations in near -field earthquakes. Keywords: Near-field earthquakes, moment frames, affect, behavior, Accelerogram compatibility with structural mechanism spectrum.
EN
In this paper, the application of tuned mass damper in improving the response of structures is considered. At first, three frames of 3, 9 and 20 stories are evaluated in which time history analysis is done according to El – Straw earthquake. The maximum reduction of among the three mentioned frames belongs to a 20-stories structure in which the rate of story displacement reduction is between 25 to 45%, and this indicates that by increasing the height of the structure, the performance of tuned mass damper improved. In the second part, the effect of semi-active tuned mass damper is studied on a 10-stories frame. Studies showed that using a tuned mass damper system with viscous damper with controller force decreases the average of maximum displacement of roof story down to 39.9 % and this amount of reduction is 22.8% for semi-active tuned mass damper. Finally, the performance of tuned Single and multiple mass Damper is evaluated on a 20-stories frame, and the results show that single and multiple dampers decrease structures ‘responses and the performance of tuned multiple dampers depends on the mass and frequency ratio and also concluded that the performance of tuned multiple mass dampers is reduced by transition to middle of the structure stories.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.