Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 42

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
The effect of heat treatment on the corrosion resistance of Ti-6Al-4V alloy was investigated in the artificial saliva solution (MAS). It has been revealed that the thermal annealing treatment temperature favors the cathodic reactions and reduce the protective properties of passive film. The heat treatment causes the enrichment of β phase in vanadium. The lowest corrosion resistance in the artificial saliva revealed the Ti-6Al-4V alloy heated for 2 hours at 950°C. Heterogeneous distribution of vanadium within the β phase decreases the corrosion resistance of the Ti-6Al-4V.
EN
The aim of this work is to develop a numerical model capable of predicting the grain density in the Mg-based matrix phase of an AZ91/SiC composite, as a function of the total mass fraction of the embedded SiC particles. Based on earlier work in a range of alloy systems, we assume an exponential relationship between the grain density and the maximum supercooling during solidification. Analysis of data from cast samples with different thicknesses, and mass fractions of added SiCp, permits conclusions to be drawn on the role of SiCp in increasing grain density. By fitting the data, an empirical nucleation law is derived that can be used in a micro model. Numerical simulation based on the model can predict the grain density of magnesium alloys containing SiC particles, using the mass fraction of the particles as inputs. These predictions are compared with measured data.
EN
The influence of the electrode geometry on the microstructure and corrosion behaviour of Co-Mo nano-crystalline coatings elaborated by electrodeposition is studied. The corrosion behaviour was determined in the Ringer’s solution at 25°C. Electrodeposition mechanisms are also discussed as a function of the electrode geometry. The electrode geometry was found to affect the growth rate and, under certain conditions, the microstructure (existence of channels and pores). It does not have influence on the corrosion behaviour.
EN
The influence on the corrosion behaviour of Co-Mo nano-crystalline coatings of dissolved oxygen is studied in the Ringer’s solution and artificial saliva at 25°C. This was done by means of potentiodynamic tests and surface observations. It was shown that dissolved oxygen has no influence on passivity, oxidation of the coating and selective dissolution of cobalt. By contrast, dissolved oxygen affects corrosion. General corrosion was observed in the Ringer’s solution whereas pitting corrosion was found in artificial saliva.
EN
The effect of the heat treatment on the corrosion resistance of Ti-6Al-4V alloy was investigated in the artificial saliva solution (MAS). It has been revealed that the thermal annealing treatment temperature significantly changes the properties of the passive film formed on Ti-6Al-4V alloy and decreases its corrosion resistance in the artificial saliva. Enrichment in vanadium of passive film formed on the specimen after heat treatment Ti-6Al-4V_HT favors the cathodic reactions and reduce the protective properties of passive film.
PL
W pracy badano wpływ obróbki cieplnej na odporność korozyjną stopu Ti-6Al-4V w roztworze sztucznej śliny. Wykazano, że podczas obróbki cieplnej zachodzą zmiany w składzie chemicznym na powierzchni stopu Ti-6Al-4V, co prowadzi do obniżenia jego odporności korozyjnej w roztworze sztucznej śliny. Wzbogacenie powierzchni stopu Ti-6Al-4V_HT w wanad podczas obróbki cieplnej faworyzuje reakcje katodowe i obniża właściwości ochronne warstwy pasywnej.
EN
Titanium alloys used in medical applications (especially dentistry) are exposed to the actions of various compounds that appear periodically in the mouth. Fluorine compounds are dangerous for the surface of titanium alloys, because they generate a dissolution of the passive layer. In this way, they destroy the surface of dental implants and cause the absorption of metal ions into the human body. The presented work was aimed to describe the effect of fluoride ions on the corrosive behavior of the commercial Ti-6Al-4V and new Ti-10Mo-4Zr alloys that can be used in stomatology. Electrochemical measurements such as open circuit potential (OCP), linear sweet voltamperometry (LSV) and impedance spectroscopy (EIS) were performed to get information on the corrosive behavior of titanium in artificial saliva solutions (MAS) with different concentrations of NaF. It has been revealed that a high concentration of fluoride ions enhance the current density in the anodic domain, especially for the Ti-10Mo-4Zr alloy. EIS measurements performed at a potential of 0.5 V vs. AgCl (3 M KCl) show that the Ti-10Mo-4Zr alloy has a typical two-layer structure of its passive film. This passive film consists of the outer and inner layers, respectively. The resistance of the outer layer is significantly lower than the resistance of the inner layer.
EN
The influence of polysaccharide chitosan coatings on the corrosion resistance of magnesium alloys Mg1Ca, Mg1Ca1Si and Mg4Zn1Ca is studied in 0.1 M sodium sulphate solution. It has been shown that localized corrosion of all magnesium alloys proceeds along grain boundaries and around precipitates. After long-term immersion of magnesium alloys (Mg1Ca and Mg4Zn1Ca) metallic ions are detected in the solution. The chitosan and chitosan/TiO2 composite coatings accelerate corrosion of Mg1Ca, Mg1Ca1Si and Mg4Zn1Ca in sodium sulphate based solutions.
PL
Badano wpływ polisacharydowych chitozanowych powłok na odporność korozyjną stopów magnezu typu Mg1Ca , Mg1Ca1Si i Mg4Zn1Ca w 0,1 M roztworze siarczanu VI sodu (Na2SO4). Korozja tych stopów przebiega wzdłuż granic ziaren i wokół wydzieleń. Po kilkudziesięciu godzinach ekspozycji stopów w roztworze elektrolitu jony metali były obecne w roztworze w przypadku stopów Mg1Ca i Mg4Zn1Ca. Obecność powłok chitozanowych i powłok chitozanowych zawierających TiO2 powodowała przyspieszenie korozji stopów magnezu w roztworze siarczanu VI sodu.
EN
The effect of rapid cooling by the vacuum suction casting method (VSC) on the microstructure and electrochemical response of the as-cast 5052 aluminium alloy is presented. The VSC method allowed us to obtain massive samples with a very high cooling rate (102 – 103)oC/s. The microstructure of the quick-cooled sample (QC) has been significantly changed. Finer grains and more-homogeneous intermetallic phase distribution has been observed. Corrosion potential (OCP) and polarization measurements (LSV) revealed a higher activity of the QC alloy than ingot (IN), which leads to a denser and thicker corrosion-product formation on the surface. Electrochemical Impedance Spectroscopy (EIS) indicates higher resistance values, which suggests a greater thickness of the corrosion products.
EN
The use of carbon fiber composites (CFC) for different applications is widespread. Carbon-based materials show, however, significant oxidative degradation in air. Modern materials are subjected to aggressive, corrosive environment. This type of environment may strongly reduce their mechanical properties. For the protection of CFC, it was necessary to apply coatings to the composite surface. In the presented paper, a chromium/chromium nitride (Cr/Cr2N) multilayer structure has been selected as the inner part. The outer part of the coating was a hydrogenated amorphous carbon (a-C:H), gradually implanted by Cr nanocrystals. The application of transmission electron microscopy (TEM) indicated that the proposed deposition method allowed the formation of a Cr/Cr2N multilayer of Λ = 150 nm, topped with a-C:H+ Cr23C6 composite of a varied carbides density. The micro-hardness of the deposited coatings was up to 14 GPa (at a load of 2 and 5 mN). The microstructure of the deposited coatings was described in detail by means of TEM in the authors’ recently published paper [1]. This paper is a continuation thereof, aimed at describing microstructure changes after a localized corrosion process. In order to study localized corrosion in coatings, particularly in metallic (Cr) interlayers, the potential measurements and voltammetry experiments were performed in a Ringer solution. The open-circuit potential reaches stable values after a sufficient time period. The results indicated that the presence of a-C:H+Cr23C6, the outer part of the coating, speeds up the localized corrosion process in Cr interlayers in the inner part of a coating.
EN
The microstructure and the corrosion behaviour in the Ringer’s solution of Co-Mo coatings electrodeposited on pure Co is investigated using a microcapillary with a diameter of 300 μm. The presence of defects (cracks and pores) and the oxygen content are important parameters affecting the electrochemical behaviour of coatings.
PL
Mikrostruktura i korozyjne zachowanie się elektrochemicznie osadzonych powłok Co-Mo na powierzchni kobaltu było badane w roztworze Ringera przy użyciu mikrokapilary o średnicy 300 μm. Badania wykazały, że parametrami mającymi istotny wpływ na elektrochemiczne osadzanie się powłok Co-Mo są obecność defektów takich jak (szczeliny i pory), a także obecność tlenu.
EN
The corrosion behaviour of two aluminium alloys (AA1050 and AA5052) and 316L stainless steel was studied in 30% ethylene glycol and propylene glycol water-based solution. The sample made of 316L stainless steel exhibits the highest corrosion resistance in all testing solutions. It was shown that investigated aluminium alloys show comparable electrochemical behaviour in both water-glycol solutions. In the case of ethylene glycol testing solution higher values of the cathodic and anodic current densities were found for all investigated samples. Therefore, the solution of ethylene glycol is a more corrosive environment compared to the propylene glycol solution.
PL
Korozyjne zachowanie się stopów aluminium AA1050 i AA5052, a także austenitycznej stali 316L było badane w 30% roztworach wodnych glikolu etylenowego i glikolu propylenowego. Najwyższą odporność na korozję w tych środowiskach wykazuje stal 316L. Stopy aluminium wykazują podobne elektrochemiczne zachowanie w obu roztworach glikolowych. W roztworze glikolu etylenowego zarówno w obszarze katodowym jak i anodowym obserwuje się wyższe prądy dla badanych stopów. W związku z tym, roztwór glikolu etylenowego jest bardziej agresywnym pod względem korozyjnym niż roztwór glikolu propylenowego.
12
Content available remote Corrosion resistance of titanium alloys in the artificial saliva solution
EN
Purpose: The purpose of this article was to characterize the corrosion behaviour and compare two biomedical titanium alloys (Ti-6Al-4V and Ti-10Mo-4Zr) in an artificial saliva solution (MAS) containing lactic acid and hydrogen peroxide (H2O2) used in dentistry. The addition of these two compounds simulate the situation, where the alloy is implanted in the human body and hydrogen peroxide is generated by the inflammatory reaction and lactic acid is release by bacterial in the oral cavity. Design/methodology/approach: In this studies were used following electrochemical techniques: Open Circuit Potential (OCP), Linear Sweep Voltamperometry (LSV), Chronoamperometry at constant potential and Electrochemical Impedance Spectroscopy (EIS). Electrochemical impedance spectra were carried out at the 0.5 V vs. Ag/AgCl potential. The EIS data were fitted using the ZViev software. Findings: The results presented in the work demonstrate that the titanium alloys have a good corrosion resistance. The corrosion behaviour was determined by surface condition of alloys and presence different chemical compounds in the solution. For Ti-10Mo-4Zr titanium alloy in MAS with different concentration of hydrogen peroxide in anodic domain it was seen more clearly. Research limitations/implications: In the future passive films of both titanium alloys will be investigated by: X-ray photoelectron spectroscopy (XPS) and scanning electron spectroscopy (SEM). Originality/value: The corrosion behaviour of biomedical titanium alloy contains molybdenum and zirconium selected as safe alloying elements for human body is presented and compared to commercial Ti-6Al-4V alloy. The corrosion resistance of the titanium alloys was investigated in the artificial saliva solution with addition of lactic acid and hydrogen peroxide.
13
Content available Corrosion Resistance of High-Alloyed White Cast Iron
EN
The paper presents the results of corrosion resistance tests carried out on high-alloyed white cast iron. Tests were performed in 0.1 M NaCl by the technique of linear voltammetry. The test material was collected from six high-vanadium cast iron melts with a variable content of carbon and vanadium, and thus with different microstructure. Studies have confirmed that the type of crystallised microstructure has a very important effect on the alloy corrosion resistance. The highest corrosion resistance showed the alloy with a ferritic matrix containing the spheroidal precipitates of vanadium carbide VC, while the lowest had the eutectic alloy with a pearlitic matrix.
PL
W pracy przedstawiono wyniki badań odporności na korozję wysokostopowego żeliwa białego. Badania przeprowadzono w 0,1M roztworze NaCl techniką woltamperometrii liniowej. Materiał do badań pobrano z sześciu wytopów żeliwa wysoko-wanadowego o zmiennej zawartości węgla i wanadu, a tym samym o różnej mikrostrukturze. Badania potwierdziły, że rodzaj wykrystalizowanej mikrostruktury ma bardzo istotny wpływ na odporność na korozję stopu. Najwyższą odporność na korozję wykazał stop o osnowie ferrytycznej ze sferoidalnymi wydzieleniami węglików VC, natomiast najniższą - eutektyczny stop o osnowie perlitycznej.
PL
Ze względu na powszechne wykorzystanie stopów tytanu w stomatologii, w pracy podjęto badania elektrochemiczne stopów tytanu: Ti-10Mo-4Zr i Ti-6Al-4V, których celem było określenie właściwości korozyjnych podczas ekspozycji w fizjologicznym roztworze sztucznej śliny, w temperaturze 37 °C, pH = 8,0 i swobodnym dostępie tlenu, a następnie modyfikacji roztworu poprzez dodatek kwasu mlekowego oraz fluorku sodu. Odporność korozyjną obu stopów porównano na podstawie badań potencjału korozyjnego i potencjodynamicznych krzywych polaryzacyjnych wykonanych techniką liniowej woltamperometrii (LSV).
EN
Titanium alloys are used in medicine and dentistry due to perfect combination of their high strength, corrosion resistance and biocompatibility. Currently, titanium alloys are among the most attractive metallic materials used to manufacture such implants as artificial hip joints, knee joints, intervertebral discs, screws securing the fracture. Most kinds of screws used in dentistry for basic fixing of ceramic dental prostheses are made from titanium alloys. Widespread use of titanium alloys in dentistry is the reason for electrochemical research on two titanium alloys: Ti-6Al-4V and Ti-10Mo-4Zr. The aim of the research was to determine the corrosion when the alloy is exposed to physiological artificial saliva solution at the temperature of 37 °C, pH = 8.0 and in aerated solution and modification of saliva solution: added lactic acid and sodium fluoride.
PL
Referat przybliża doświadczenia w zastosowaniu napędów regulowanych wentylatorów spalin z wykorzystaniem przemienników częstotliwości dla typowych dla energetyki polskiej kotłów węglowych 230MW, oraz dla fluidalnego kotła biomasowego. Referat przybliża zachowanie tych napędów w pracy normalnej kotła, w testowanych stanach awaryjnych kotła oraz w stanach dynamicznych kotła związanych z wymaganiami dotyczącymi regulacji bloku.
EN
The paper brings closer experiences in application of variable speed induced draft fans with frequency converters in typical for polish power engineering industry 230 MW coal boilers and in biomass CFB boiler. The paper brings closer the behavior of drives in normal boiler operation, in tested emergency states of the boiler and in dynamic states of the boiler connected with requirements related to controllability of the block.
16
Content available remote Przyczyny grzania się bednarki i żył powrotnych kabli 6 kV
PL
W artykule przedstawiono analizę przyczyn grzania się bednarki i żył powrotnych w sieci kablowej 6 kV, w dużym zakładzie przemysłowym. W oparciu o przeprowadzone symulacje oraz pomiary wskazano konieczne, niezbędne zmiany w istniejącym układzie celem wyeliminowania przyczyn grzania się bednarki oraz żył powrotnych: zastosowanie odgromnikow oraz jednostronne uziemienie żył powrotnych.
EN
This paper presents an analysis of the causes heating of the strips and return and live in a large Network of 6 kV plant. Based on our simulations and measurements indicated necessary, the necessary changes In the existing system in order to eliminate the causes heating of the hoop and return conductors - the use of surze arresters and unilaterally earthing of cable sheaths
17
Content available remote Diagnostyka silnika indukcyjnego napędu wentylatora spalin
PL
Artykuł przedstawia prace diagnostyczne przeprowadzone dla silnika indukcyjnego w celu wykrycia źródła nietypowego dźwięku występującego podczas pracy. Wykonano kontrolę niesymetrii klatki oraz dokonano analizy widm prądów stojana w celu wykrycia symptomów niecentryczności zarówno statycznej, jak i dynamicznej.
EN
The results of induction motor diagnostic in order to detect the source of an unusual sound occurring during operation were presented in this paper. The work included the control of cage asymmetry and the analysis of a stator current harmonic spectrum to detect symptoms of static and dynamic eccentricity both.
PL
W artykule przedstawiono propozycję modyfikacji wektorowego układu regulacji silnika synchronicznego z magnesami trwałymi, w celu zapewnienia wymaganego momentu obrotowego oraz utrzymania zadanych obrotów silnika podczas zapadu napięcia. Na podstawie przeprowadzonych symulacji pracy silnika synchronicznego z magnesami trwałymi stwierdzono możliwość poprawy odporności regulowanych napędów prądu przemiennego z silnikami synchronicznymi z magnesami trwałymi na zapady napięcia.
EN
This paper presents a proposal to modify the PM synchronous motor vector control system in order to provide the required torque and the reference speed of drives during voltage sags. Based on the simulations, the immunity improvement of adjustable AC drives with PM synchronous motors on voltage sags has been confirmed.
19
Content available remote Analiza pracy silnika indukcyjnego w warunkach zapadu napięcia
PL
W artykule przedstawiono propozycję modyfikacji wektorowego układu regulacji silnika indukcyjnego w celu zapewnienia wymaganego momentu obrotowego oraz utrzymania zadanych obrotów silnika podczas zapadu napięcia. Na podstawie symulacji oraz pomiarów w laboratorium stwierdzono poprawę odporności regulowanych napędów prądu przemiennego z silnikami indukcyjnymi na zapady napięcia.
EN
This paper presents a proposal to modify the induction motor vector control system in order to provide the required torque and the reference speed of drives during voltage sags. Based on the simulations and laboratory measurements of the induction motor, the immunity improvement of adjustable AC drives with induction motors on voltage sags has been confirmed.
PL
Celem pracy było porównanie korozyjnego zachowania się najbardziej popularnego stopu tytanu Ti-6Al-4V, stosowanego na implanty biomedyczne, ze stopem Ti-10Mo-4Zr. Badania odporności korozyjnej zostały przeprowadzone w fizjologicznym roztworze Hank’a. Odporność korozyjną obu stopów porównano na podstawie badań potencjału korozyjnego i potencjo dynamicznych krzywych polaryzacyjnych wykonanych techniką liniowej woltamperometrii (LSV). Stop tytanu Ti-10Mo-4Zr posiada niższy moduł Younga wynoszący 74 ÷ 86 GPa niż stop Ti-6Al-4V (110 GPa). Jest wskazane, aby materiały metaliczne stosowane w implantologii wykazywały moduły Younga raczej niższe, to znaczy zbliżone do modułu Younga kości około 30 GPa. W związku z tym, biorąc pod uwagę właściwości mechaniczne, stop Ti-10Mo-4Zr jest bardziej atrakcyjnym materiałem przeznaczonym na implanty. Badania odporności korozyjnej w fizjologicznym roztworze Hank’a wykazały jednoznacznie, że stop Ti-10Mo-4Zr, podobnie jak stop Ti-6Al-4V, wykazuje bardzo dobra odporność na korozję. Wysoka odporność obu stopów tytanu jest związana z tworzeniem się termodynamicznie stabilnej i trwałej warstwy tlenkowej zawierającej głównie tlenek tytanu TiO2. Bardzo dobra odporność na korozję i korzystniejsze właściwości mechaniczne wskazują, że jednofazowy stop Ti-10Mo-4Zr jest bardzo atrakcyjnym materiałem przeznaczonym na implanty biomedyczne.
EN
The aim of this paper was the comparison of the corrosion behavior two titanium alloy Ti-6Al-4V and Ti-10Mo-4Zr. Up to now Ti-6Al-4V alloy is common used as a bioimplants. Corrosion resistance tests for both Ti alloys have been performed in Hank's physiological solution. Corrosion resistance of both alloys were compared on the basis of the corrosion potential measurements and polarization curves obtained by means of linear voltammetry technique (LSV). Titanium alloy Ti-10Mo-4Zr has a lower Young’s modulus of about 74 GPa compare to Ti-6Al-4V alloy (110 GPa). It is desirable that the metallic materials used for implants should have a rather low Young's modules that is similar to the Young's modulus of human bones (30 GPa). Therefore, considering the mechanical properties the Ti-10Mo-4Zr alloy is very attractive as a material for bioimplants. The study of corrosion resistance in Hank's physiological solution clearly showed that the Ti-10Mo-4Zr like Ti 6Al-4V-shows very good resistance to corrosion. High corrosion resistance of both titanium alloys is related to the formation of thermodynamically stable oxide layer consists mainly of titanium dioxide TiO2. Very good corrosion resistance and favorable mechanical properties indicate that the single-phase Ti-10Mo-4Zr alloy is a very attractive material for biomedical implants.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.