Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 28

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
EN
The paper presents the balance of electricity and fuel oil consumption of a medium-sized 24-hour store. Measurements of electricity consumption of individual components of the balance were made. Their shares over the 12 months of measurements were determined. Opportunities to reduce electricity consumption by changing the type of lighting of the facility were identified. . lighting replacement reduced electricity consumption by 38535.8 kWh, a total reduction of 21.2% in the store's annual electricity consumption.
2
Content available remote Warunki zatarcia dla pary ciernej stal-tlenek chromu (Cr2O3)
PL
W poprzednim artykule zostały przedstawione wyniki badań dla próbek stali pokrytej warstwą węgliku wolframu (WC), dla której okazało się, że proces zatarcia przebiega podobnie jak dla par roboczych stal-stal. W niniejszym artykule przedstawione są wyniki badań dla próbek pokrytych tlenkiem chromu, dla którego pierwsze objawy zatarcia pojawiły się dla obciążeń normalnych o wartościach Pn = 0,5-1,5 kN. Po czym następowało wahanie wartości sił stycznych i wzrost temperatury próbek. Przy wartościach siły normalnej na poziomie Pn = (1,2-2,0) kN następował gwałtowny wzrost sił stycznych i dalszy wzrost temperatury próbek. Maksymalna temperatura próbek wynosiła od 82,7°C do 111°C. Powierzchnie próbek nie wykazywały istotnego zużycia ciernego.
3
Content available Systems of heat pumps in water
EN
The number of words in abstract should be placed in a range between 100 and 300 words. It should be justified, Times New Roman font 12 pt., spacing before 10 pt., spacing between lines 1pt. The text should be clear and complex and involve the base problems of a paper, information about methodology and results, a conclusion is crucial.
EN
The use of waste heat in many branches of industry is limited due to temperature in the range of 30 to 100°C. One of the methods of using waste heat are devices that implement the Organic Rankine Cycle (ORC). In currently used ORC systems, the heat source temperature is at least 80oC, while the low temperature heat source (usually atmospheric air) has a temperature of 30oC. The work analyzes the influence of the organic fluids properties on the performance of the proposed installation driven by the waste heat and working based on the ORC. The basic operation parameters in nominal conditions were determined for three selected natural refrigerants R290, R600a, R717 and one synthetic R245fa. The condensing temperature 30oC were defined as a nominal value. The research results compare how the generated electric power will change depending on the temperature difference between the temperature of the heat source and the temperature of evaporation. It turns out that for a device with finite dimensions, the maximum power is obtained for a specific evaporation temperature. And this is not the highest temperature that can be achieved. The highest evaporation temperature allows for the highest efficiency of the system, but not the maximum of capacity.
5
Content available remote Weryfikacja doboru średnicy rury skraplacza dla bloku 200 MW
PL
W skraplaczach energetycznych bloków parowych dochodzi do odprowadzenia ciepła kondesacji pary do otoczenia. Geometria (powierzchnia wymiany ciepła, średnica rury) i warunki pracy skraplaczy energetycznych wpływają na osiągi bloku (moc i sprawność). Wraz ze zmianą średnicy rury skraplacza następuje zmiana warunków wymiany ciepła i oporów przepływu wody chłodzącej, co przekłada się na ciśnienie kondensującej pary, moc generowaną przez turbinę, moc potrzebną do napędu pompy wody chłodzącej i sprawność bloku. Ze względu na wydłużenie czasu pracy bloków energetycznych klasy 200 MW i ich większą elastyczność pracy w systemie elektroenergetycznym w artykule dokonano weryfikacji doboru średnicy rury skraplacza w celu zbadania możliwości poprawy osiągów. Model bloku 200 MW został stworzony w programie Ebsilon. Kryterium optymalizacyjnym jest maksymalizacja mocy i sprawności netto bloku.
EN
In steam power plants condensers, the condensation heat of the steam is removed to the environment. The geometry (heat transfer surface area, tube diameter) and the operating conditions of the steam condensers influence the power plant performance (power and efficiency). As the diameter of the steam condenser tube changes, the heat transfer conditions and the cooling water flow resistance change, which translates into the pressure of condensing steam, the power generated by the turbine, the power needed to drive the cooling water pump and the power plant efficiency. Due to the extension of the operating time of 200 MW class power units and their greater flexibility of operation in the power system, the article verifies the selection of the diameter of the steam condenser tube in order to investigate the possibilities of improving performance. The 200 MW unit model was created in the Ebsilon program. The optimization criterion is to maximize the power and net efficiency of the unit.
PL
Przegląd literatury pokazuje wiele danych dotyczących istotnego wpływu warstw ceramicznych na zużycie współpracujących elementów maszyn. Wpływ ten jest korzystny zarówno w niskich jak i w podwyższonych temperaturach. Mało natomiast jest informacji na temat wpływu warstw ceramicznych na zjawisko zatarcia. Należy tu przewidywać działanie dwóch przeciwstawnych czynników. Z jednej strony większa odporność na ścieranie i wyższa temperatura topienia warstw ceramicznych niż stali, może prowadzić do podwyższenia odporności na zatarcie. Z drugiej strony mniejsze przewodnictwo cieplne w stosunku do przewodnictwa cieplnego stali, powoduje wzrost temperatury powierzchni elementów pozostających w kontakcie. Fakt ten prowadzi do szybszego niszczenia warstw granicznych i jednocześnie powoduje obniżenie właściwości smarnych oleju stosowanego do smarowania, powodując w konsekwencji zmniejszenie grubości tworzącego się filmu smarnego i obniżenie odporności na zacieranie. W związku z tym podjęto badania zacierania pary trybologicznej, którą stanowią walec stalowy i próbka stalowa pokryta warstwą ceramiczną.
EN
The literature review shows a lot of data on the significant influence of ceramic layers on the wear of cooperating machine elements. This effect is beneficial at both low and elevated temperatures. However, little information is available on the influence of ceramic layers on the seizure phenomenon. Two opposing factors should be expected here. On the one hand, higher abrasion resistance and a higher melting point of ceramic layers than for steel may lead to increased seizure resistance. On the other hand, the lower thermal conductivity in relation to the thermal conductivity of steel causes an increase in the surface temperature of the elements in contact. This fact leads to a faster destruction of the boundary layers and at the same time reduces the lubricating properties of the oil used for lubrication, resulting in a reduction in the thickness of the lubricating film formed and a reduction in the resistance to scuffing. Therefore, research was undertaken on the mashing of the tribological vapor, which is a steel cylinder and a steel sample covered with a ceramic layer.
PL
Rozwój techniki spowodował potrzebę stosowania materiałów o podwyższonych własnościach. Dotyczy to zarówno własności mechanicznych, własności związanych z odpornością na korozję i erozję, odpornością na ścieranie oraz jako bariery cieplne i elektryczne. Własności tych nie da się uzyskać stosując jednorodne materiały. Z pomocą przychodzą tu techniki łączenia jednych materiałów z drugimi. Jedną z takich metod jest nanoszenie powłok ceramicznych na materiały metaliczne. Artykuł skupia się na przeglądzie metod nanoszenia ceramiki na metale z opisem ich własności oraz wypunktowując wady oraz zalety.
EN
The development of technology has resulted in the need to use materials with improved properties. This applies to both mechanical properties, properties related to corrosion and erosion resistance, abrasion resistance and as thermal and electrical barriers. These properties cannot be obtained by using homogeneous materials. The techniques of joining one material to another come in handy here. One such method is the application of ceramic coatings to metallic materials. The article focuses on a review of the methods of applying ceramics to metals with a description of their properties and highlighting the advantages and disadvantages.
PL
Materiały ceramiczne jak większość materiałów ulega procesowi utleniania się. Zjawisko to może być niezwykle niekorzystne z punktu widzenia wytrzymałości mechanicznej. Problem z utlenianiem szczególnie uciążliwy jest w przypadku nakładania powłok metodami plazmowymi, podczas których temperatura procesu jest bardzo wysoka co w naturalny sposób sprzyja utlenianiu się. W ramach badań postanowiono sprawdzić jak metoda natryskiwania plazmowego wpływa na właściwości nakładanej warstwy. Przebadano kilka metod natryskiwania, kontrolując utlenianie powłoki. W kolejnym kroku poszczególne powłoki poddawano badaniom diagnostycznym. Został określany stopień utleniania powłoki za pomocą rentgenowskiej analizy fazowej. Następnie przebadano właściwości mechaniczne otrzymanych powłok. Szczególną uwagę zwrócono na metodę natryskiwanie pod ciśnieniem atmosferycznym, z pierścieniową strugą ochronną. W ramach badań dokonano ukształtowania pierścieniowej strugi ochronnej zabezpieczającej przed utlenianiem materiał proszkowy, tworzący powłokę.
EN
Ceramic materials, like most materials, undergo the process of oxidation. This phenomenon can be extremely unfavorable from the point of view of mechanical strength. The problem with oxidation is particularly troublesome in the case of plasma coating, where the process temperature is very high, which naturally promotes oxidation. As part of the research, it was decided to check how the plasma spray method affects the properties of the applied layer. Several spraying methods have been tested to control the oxidation of the coating. In the next step, individual coatings were subjected to diagnostic tests. The degree of oxidation of the coating was determined by means of X-ray phase analysis. Then, the mechanical properties of the obtained coatings were tested. Particular attention was paid to the atmospheric pressure spraying method with an annular protective jet. In the research, an annular protective stream was shaped to protect the powder material forming the coating against oxidation.
PL
Klasyczne układy ze skojarzonym wytwarzaniem energii elektrycznej i ciepła wymagają wprowadzenia dodatkowego medium grzejnego. Alternatywnym rozwiązaniem jest bezpośrednie wykorzystanie gazów wylotowych z silnika cieplnego. Dzięki wysokiej temperaturze oraz znacznym strumieniem ciepła w stosunku do mocy, gazy wylotowe z turbiny Gazowej (TG) zostały z powodzeniem zastosowane w skali przemysłowej jako: podgrzane powietrze w piecach przemysłowych, źródło ciepła do bezpośredniego osuszania oraz w absorpcyjnych urządzeniach chłodniczych. W artykule zawarto przegląd udokumentowanych zastosowań TG w przemyśle przetwórczym z uwzględnieniem uwarunkowań technicznych i ekonomicznych, jak również, kryteria doboru TG. Opisane rozwiązania pozwoliły na obniżenie energochłonności w zakresie od 7% do 20% oraz redukcję kosztów zużywanej energii na poziomie 15-30%. Redukcja energochłonności obniża ilość emitowanego CO2. Osiągnięto także całkowitą sprawność układów kogeneracji powyżej 90%. Dokonano również wstępnej oceny możliwości integracji gazów wylotowych dla TG produkowanych przez Baker Hughes w polskim przemyśle.
EN
The typical combined heat and power plants require the introduction of additional heating medium. The alternative solution is the direct integration of the exhaust gases from heat engine. High temperature and high exhaust energy to power ratio, enabled the integration of Gas Turbine (GT) exhaust gases at industrial scale as: preheated combustion air for industrial furnaces, heat source for direct drying and for absorption chillers. The article comprises the review of documented applications of GTs with direct exhaust gas integration in the process industry focusing on technical and economic considerations, as well as GTs selection criteria. The described solutions allowed to reduce specific energy consumption by 7-20% or the costs of energy consumption by 15-30%. The reduction of specific energy consumption allows to decrease the amount of CO 2 emitted. The overall efficiency of cogeneration plant above 90% was achieved. The preliminary feasibility assessment of the opportunities to integrate exhaust gases in the polish industry for the Gas Turbines produced by Baker Hughes is done.
PL
W artykule przedstawiono porównanie temperatur oddziałujących na wentylatory wyciągowe dla różnych koncepcji systemów oddymiania i odprowadzania ciepła z przestrzeni objętej pożarem. Zaprojektowane systemy mają za zadanie: zapewnić odpowiednie warunki ewakuacji ludzi z zagrożonej przestrzeni, umożliwić bezpieczne prowadzenie akcji ratowniczo- gaśniczej, zmniejszyć straty materialne oraz zapobiec rozprzestrzenianiu się pożaru. Zastosowanie metod numerycznych obliczeniowej dynamiki płynów do analizy temperatury w wentylacji pożarowej daje możliwość odwzorowania wpływu warunków środowiskowych na działanie systemu oraz porównania różnych koncepcji realizacji systemów na etapie projektowania. W związku z tym w niniejszej pracy porównano 9 przykładowych rozwiązań rozmieszczenia wentylatorów wyciągowych pod kątem oceny klasy odporności temperaturowej wentylatorów wyciągowych. Dla wszystkich scenariuszy średnia temperatura oddziałująca na wentylatory wyciągowe nie przekraczała 300 ⁰C, przy czym w najbardziej skrajnych przypadkach różnica temperatur przekraczała 100 ⁰C. Zaobserwowano duże różnice średniej temperatury w poszczególnych punktach pomiarowych, spowodowane różną geometrią otworów odprowadzających dym i gorące gazy pożarowe z przestrzeni pożarowej. Spowodowane są one również zastosowaniem modelu turbulencji LES, w którym z większą starannością odwzorowane są fluktuacje parametrów wynikające z przebiegu pożaru. Wykorzystanie numerycznych metod obliczeniowej dynamiki płynów do analizy temperatury daje również możliwość oceny klasy odporności temperaturowej innych elementów wentylacji pożarowej, takich jak przewody dymowe, klapy przeciwpożarowe czy kurtyny dymowe. Oszacowanie temperatury metodami obliczeniowej dynamiki płynów jest przybliżeniem rzeczywistości umożliwiającym analizę wpływu wielu czynników, dlatego może stanowić istotną pomoc dla projektantów systemów wentylacji pożarowej w doborze odpowiedniej klasy odporności temperaturowej wentylatorów wyciągowych.
EN
The article presents a comparison of temperatures affecting the exhaust fans for different concepts of smoke and heat extraction systems from the space covered by the fire. Designed systems are intended to: provide adequate conditions for evacuation of people from the endangered space, enable safe rescue and firefighting, reduce material losses and prevent the spread of fire. The use of numerical methods of computational fluid dynamics for temperature analysis in fire ventilation gives the possibility to map the impact of environmental conditions on the system operation and to compare different concepts of systems implementation at the design stage. As a result, this paper compares 9 sample exhaust fan placement solutions with respect to evaluating the temperature resistance class of the exhaust fans. For all scenarios, the average temperature affecting the exhaust fans did not exceed 300 ⁰ C, with a difference in temperatures exceeding 100 ⁰ C in the most extreme cases. Large differences in average temperature in individual measuring points were observed, caused by different geometry of openings leading away smoke and hot fire gases from the fire space. Caused also by application of LES turbulence model, in which fluctuations of parameters resulting from the course of fire are represented with more care. The use of numerical methods of computational fluid dynamics for temperature analysis gives also the possibility to evaluate the temperature resistance class of other fire ventilation elements such as smoke ducts, fire dampers or smoke curtains. Temperature estimation with the use of computational fluid dynamics methods is an approximation of reality enabling to analyze the influence of many factors, so it can be a significant help for designers of fire ventilation systems in the selection of appropriate temperature resistance class of exhaust fans.
EN
Following the entry into force of the Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006, the scope of refrigerants, which have so far been commonly used is very limited. All preferred refrigerants are mostly flammable and explosive, and they include R32, R1234yf, R1234ze, R290 (propane), R600a (isobutane), R717 (ammonia). However, it should be noted that refrigerants such as R32, R1234yf, R1234ze are classified as mildly flammable and has been created for them, in accordance with ISO 817 standard, special group called A2L. It is also worth noting that the new classification moved ammonia to the group B2L - that means is toxic and mildly flammable. The article focuses on defining the conditions in which there is possible to build safely split installation in which the propane is a refrigerant. It turns out that small splits are devices which can be used safely with R290 in most cases.
PL
Ceramika, laikowi kojarzy się z wyrobami z wypalanej gliny. Natomiast materiały ceramiczne obejmują sobą bardzo szeroką grupę związków chemicznych, a ich zastosowanie jest bardzo szerokie. Zarówno w postaci ceramiki litej jak i powłok ceramicznych. W obecnych czasach, przemył maszynowy trudno sobie wyobrazić bez ceramiki, choć jeszcze niedawno kojarzony był tylko i wyłącznie z materiałami metalicznymi. Powłoki ceramiczne polepszają jakość maszyn użytkowych, ale także narzędzi tnących. W artykule przedstawiono wkład ceramiki w rozwój przemysłu maszynowego.
EN
Ceramics, for laymen, associate them with fired clay products. On the other hand, ceramic materials include a very wide group of chemical compounds, and their application is very wide. Both in the form of solid ceramics and ceramic coatings. Nowadays it is difficult to imagine the machine industry without ceramics, although until recently it was associated only with metallic materials. Ceramic coatings improve the quality of utility machines, but also of cutting tools. The article presents the contribution of ceramics to the development of the machine industry.
EN
This paper deals with the problem of the decreasing of electricity losses from one side and the possibility of electric vehicle charging from the small wind and sun electric generators named as renewable energy sources. The purpose of the analysis of electricity losses is to analyze the efficiency of the operating mode depending on the shape of the load schedule. Identification of the dependence of the required degree of load balancing on the coefficient of the shape of the load curve, heating coefficient and energy losses. To equalize the load schedule, it is necessary to use energy storage devices, as well as operating modes and replacement of existing equipment. One of the options for energy storage can be an electric car (V2H) connected to the house network.
PL
Artykuł dotyczy problemu zmniejszenia strat energii z jednej strony oraz możliwości ładowania pojazdów elektrycznych z małych generatorów wiatrowych i słonecznych zwanych odnawialnymi źródłami energii. Celem analizy strat energii elektrycznej jest określenie wydajności trybu pracy w zależności od kształtu harmonogramu obciążenia, oraz identyfikacja zależności wymaganego stopnia równoważenia obciążenia od współczynnika kształtu krzywej obciążenia, współczynnika nagrzewania i strat energii. W celu wyrównania harmonogramu obciążenia, konieczne jest użycie urządzeń do magazynowania energii, a także trybów pracy i wymiany istniejącego sprzętu. Jedną z opcji magazynowania energii może być samochód elektryczny (V2H) podłączony do sieci domowej.
EN
The production activity of mankind using high-ash fossil fuels for electricity generation is steadily increasing ash waste and carbon dioxide emissions into the environment. The article proposes a variant of wasteless combustion of Ekibastuz coal in a melting reactor installed under the boiler; it is envisaged to obtain, in addition to steam of energy parameters, a melt suitable for the production of building materials, sublimates of zinc, gallium and germanium, to reduce emissions of CO2 into the atmosphere and return to the process a part of carbon in CO2. An energy-saving thermal diagram of a power plant boiler has been developed on the basis of the proposed technology for the reduction of СО2, Н2О of reactor waste gases with zinc vapor to СО, Н2. The resulting excessive hydrogen will be used to displace elemental carbon from CO. The spent reagent, zinc oxide, after recovering into zinc will be used again in the process. In case of implementation, CO2 emissions into the atmosphere will be cut up to 50%, the expected payback period of the proposed system will be 1.0 - 1.5 years.
PL
Działalność produkcyjna ludzkości wykorzystująca wysokopopiołowe paliwa kopalne do produkcji energii elektrycznej stale zwiększa ilość odpadów popiołowych i emisję dwutlenku węgla do środowiska. W artykule zaproponowano wariant bezodpadowego spalania węgla Ekibastuz w reaktorze zainstalowanym pod kotłem; przewiduje się uzyskanie, oprócz pary o parametrach energetycznych, stopu odpowiedniego do produkcji materiałów budowlanych, sublimatów cynku, galu i germanu, a w celu zmniejszenia emisji CO2 do atmosfery i powrotu do procesu części węgla zawartego w CO2. Na podstawie zaproponowanej technologii redukcji СО2 i Н2О w gazach odlotowych z reaktora z parą cynku do СО i Н2 opracowany został energooszczędny schemat cieplny kotła w elektrowni. Powstała nadmierna ilość wodoru zostanie wykorzystana do wyparcia węgla pierwiastkowego z CO. Zużyty reagent, tlenek cynku, po odzyskaniu cynku zostanie ponownie wykorzystany w procesie. W przypadku wdrożenia, emisja CO2 do atmosfery zostanie zmniejszona do 50%, oczekiwany okres zwrotu z proponowanego systemu będzie wynosić 1,0 - 1,5 roku.
PL
Bloki węglowe klas 200 MW były projektowane jako podstawowe jednostki wytwórcze, które miały ograniczony zakres regulacji obciążenia. Ze względu na rosnący udział odnawialnych źródeł energii w bilansie energetycznym jednostki klasy 200 MW muszą m.in. charakteryzować się większą elastycznością (w zakresie większych zmian obciążeń). Jest to jednym z istotnych celów programu 200+. Ponadto blok nie powinien znacząco zmniejszać sprawności przy mniejszych obciążeniach, które będą często występować. W artykule dokonano analizy doboru strumienia masy wody chłodzącej przy zmiennym obciążeniu blok w zakresie od 100 % do 40 %, w celu uzyskania mak-symalnej sprawności i mocy. Model matematyczny bloku 200 MW został wykonany w komercyjnym programie Ebsilon i zwalidowany na podstawie danych pomiarowych. Na podstawie przeprowadzonej analizy wydaje się zasadne zmniejszanie strumienia masy wody chłodzącej w blokach pracujących z obciążeniem poniżej 60%.
EN
The 200 MW coal power plants were designed as basic generating units, which had a limited scope of load regulation. Due to the growing share of renewable energy sources in the energy balance, 200 MW class units must have greater flexibility (in the scope of larger load changes). In addition, these power plants should not significantly reduce efficiency at the lower loads that will often occur. The article analyzes the selection of the cooling water mass flow rate at variable load in the range from 100% to 40% in order to obtain maximum efficiency and power. The mathematical model of the 200 MW power plant was made in the commercial Ebsilon program and validated based on measurement data. On the basis of the analysis carried out, it seems reasonable to reduce the cooling water mass stream in this unit working with a load below 60%.
PL
W centrach miast występuje znaczne zanieczyszczenie powietrza. W związku z tym istnieje potrzeba lokalnego oczyszczania powietrza. W artykule przedstawiono analizę jakości powietrza w centrum Warszawy oraz sposoby poprawy jego jakości. Przeanalizowano dostępne filtry i sprawdzono ich przydatność. Wstępne badania przeprowadzono na zbudowanym stanowisku badawczym. Badano skuteczność filtracji, spadki ciśnienia i skład zanieczyszczeń przed i za przegrodą filtracyjną. Poszukiwano rozwiązania dla zanieczyszczeń o wielkości ziarna 1-2,5PM. Zbadano trzy rodzaje filtrów (pokrywę antysmogową do splita naściennego, filtr HEPA13 oraz trójstopniowy układ filtracyjny: warstwa węgla aktywnego + filtr F5 + filtr HEPA11) i określono ich przydatność do stosowania w warunkach wysokiego poziomu zapylenia w aglomeracjach wielkomiejskich.
EN
Air pollution is a significant problem in city centres. According to public health care there is a need for local authorities to propose good solutions for purification of an air. It is crucial for outdoor as well as indoor applications. In this paper the levels of PM10 and PM2.5 in the centre of Warsaw, Poland, are presented. Moreover, the experimental stand is introduced due to examination of different filtration materials. There are antismog cover for air conditioning split, HEPA13 class filter and 3-stage filtration (active carbon + F5 class filter + HEPA11 class filter) system for domestic applications. The filtration efficiency is defined and calculated upon experimental measurements of filtration materials. There is experimental stand where some parameters could be adjust. From experiments it is known the efficiency of filtration, the pressure difference and influence of moisture on filtration PM2.5 and less. A solution was considered for contamination of grain size from PM1 to PM2.5. Three types of filters were examined and their suitability for the proposed solution was evaluated. An air purification system was proposed at bus stops.
17
Content available ISEE - Intelligent System of Energy Efficiency
EN
Increasing energy efficiency is one of the priorities of the European 3x20 climate and enery package. The ISEE system - Intelligent Energy Efficiency Control is a response to the growing interest in energy saving. It is also closely related to energy efficiency and reduction of greenhouse gas emissions. The presented system also allows connecting renewable energy sources to the analyzed facilities. It is intended for a wide range of recipients.
18
Content available remote Theoretical and Experimental Analysis of Thermoelectric Power Generation
EN
This paper deals with thermoelectric technology. Selected new semi conductors with improved figures of merit are presented. Peltier modules are used to generate electric current through temperature difference. The paper indicates applications of thermoelectric modules, as interesting tools for various waste heat recovery. There are zero dimension equations describing the conditions of electric power generation including voltage and current with characteristics of the above parameters. The authors are also interested in the efficiency of electric current generation. The experimental stand, on going research and experimental measurements are described. The authors explore the resistance of the receiver placed in the electric circuit with thermoelectric elements. Finally, the experimental results are analyzed and theoretical conclusions made. Voltage generationof about 1.5 to 2.5 V was observed in the range of temperaturę difference ΔT from 65 to 85K. Measurements were taken from a bismuth telluride thermoelectric couple, which is traditionally used in cooling technology.
EN
The typical combined heat and power plants requires the introduction of additional heating medium. The alternative solution is the direct integration of the exhaust gases from heat engine. The high temperature, surplus oxygen and low water content of the GTs exhaust gases enabled the successful integration at industrial scale as: preheated combustion air for industrial furnaces, heat source for drying and for absorption chillers. The article comprises the reference list for direct exhaust gas integration of GTs produced by GE, the processes overview, GTs selection criteria, as well as the review of documented GTs applications in process industry focusing on technical and economic considerations. The described solutions allowed to reduce the specific energy consumption in the range from 7 to 20% or the costs of energy consumption by 15-30%. The overall efficiency of cogeneration plant above 90% was achieved. The preliminary assessment of potential applications for GTs produced by GE with TEG integration in Polish process industry is done.
EN
Ensuring a safe evacuation for the users of a building is a major goal when designing structures and systems protecting them against the effects of a fire. The article discusses the safety assessment for evacuation of users from a building exemplified by an analysis using computational fluid mechanics to reproduce the environmental conditions during a fire. It presents a way to evaluate the possibility of a safe evacuation of users from a facility by indicating the criteria for the assessment of conditions on the evacuation routes during emergency evacuation. In order to verify the criteria for assessing the evacuation safety, a three-dimensional model of the object under consideration has been prepared, for which a dedicated calculation solver of Fire Dynamic Simulator fluid mechanics has been used to recreate the fire conditions in the building. Prepared calculation model takes into account both the development of a fire on a given floor of the building and the simulation of the designed fire ventilation system in operation. In the paper the authors compare the assumptions used to create a calculation model and analyze their impact on the assessment of evacuation safety. Comparative analysis of the assumptions used to prepare the fire model allowed to draw conclusions particularly important for the people evaluating the evacuation safety on the basis of the analysis of the operation of fire ventilation systems using the computational fluids mechanics.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.