EN
The article presents basic issues regarding the operation process and analysis of the reliability of the fire alarm and transmission system in the distributed fire alarm system. Signals of fire and fault alarms generated from the fire alarm system (SSP) send fire monitoring. Fire monitoring consists of sending, with the confirmation, an automatic fire alarm and a fault signal to the appropriate alarm receiving centers (ACO). The reliability structure of the fire and fault alarm transmission system is presented. An analysis of reliability of independent SSP system information transmission paths was performed.
PL
W artykule przedstawiono podstawowe zagadnienia dotyczące procesu eksploatacji i analizy niezawodności systemu transmisji alarmów pożarowych i sygnałów uszkodzeniowych w rozproszonym systemie sygnalizacji pożarowej. Sygnały alarmów pożarowych oraz uszkodzeniowych generowane z systemu sygnalizacji pożarowej (SSP) przesyła monitoring pożarowy. Monitoring pożarowy polega na przesłaniu z potwierdzeniem, w sposób automatyczny alarmu pożarowego i sygnału uszkodzeniowego do odpowiednich alarmowych centrów odbiorczych (ACO). Przedstawiono strukturę niezawodnościową systemu przesyłania alarmów pożarowych i uszkodzeniowych. Przeprowadzono analizę niezawodności niezależnych torów przesyłania informacji o stanie systemu SSP.
EN
The article discusses an analysis of the operational and reliability issues, which regards selected fire alarm systems (FAS) exhibiting different functional structures. These systems are operated in a vast transport area, within a specific environment. We can distinguish three basic structures of these systems – focused, dispersed and mixed. A given system functional structure, utilized within a facility (a given area) is a function depending on the configuration, internal connections of elements and devices, and a developed fire scenario. The application of a given system structure for fire protection also depends on the legislation determining the approval of a facility (area) for use. The process of executing a scenario in the event of a fire is ensured by an algorithm implemented in the alarm central unit and other elements of the system. The implementation of all the system requirements specified within a given procedure algorithm depends on, e.g., an appropriate reliability structure and environmental conditions. The article analyses the operational process of selected FAS, which are operated within a vast transport area. It discusses the actual results of the operational process tests, e.g., repair and damage durations. Next, operational relationship graph, taking into account the conducted operational test, was developed. This enabled the determination of relationships that allow to specify the operating and reliability parameters in terms of a FAS staying in the states distinguished for the research. The FAS test methodology presented in the article, owing to meeting specific performance requirements, can be used in the course of developing a fire scenario and designing systems, taking into account various available technical solutions.
PL
W artykule przeprowadzono analizę problemów eksploatacyjnych i niezawodnościowych, która dotyczy wybranych systemów sygnalizacji pożaru (SSP) o różnej strukturze funkcjonalnej. Systemy te są użytkowane na rozległym obszarze transportowym, w określonym środowisku. Można wyróżnić trzy podstawowe struktury tych systemów - skupiona, rozproszona i mieszana. Dany rodzaj struktury funkcjonalnej systemu, który jest użytkowany w obiekcie (na danym obszarze) jest funkcją zależną od konfiguracji, wewnętrznych połączeń elementów i urządzeń oraz opracowanego scenariusza postępowania na wypadek pożaru. Zastosowanie danej struktury systemu do ochrony pożarowej zależy także od przepisów prawnych warunkujących dopuszczenie danego obiektu (obszaru) do użytkowania. Proces realizacji scenariusza w czasie pożaru jest gwarantowany przez algorytm zaimplementowany w centrali alarmowej oraz innych elementach systemu. Realizacja wszystkich wymagań wobec systemu określonych w danym algorytmie postępowania uwarunkowana jest np. odpowiednią strukturą niezawodnościową i warunkami środowiskowymi. W artykule przedstawiono analizę procesu eksploatacji wybranych SSP, które są użytkowane na obszarze transportowym. Zaprezentowano rzeczywiste wyniki badań procesu eksploatacji, np. czasy trwania naprawy oraz uszkodzenia. Następnie opracowano graf relacji eksploatacyjnych z uwzględnieniem przeprowadzonych badań eksploatacyjnych. Umożliwiło to wyznaczenie zależności pozwalających na określenie parametrów eksploatacyjnych i niezawodnościowych przebywania SSP w wyróżnionych do rozważań stanach. Przedstawiona w artykule metodyka badania SSP ze względu na spełnienie określonych wymagań eksploatacyjnych może być użyta podczas opracowywania scenariusza pożarowego oraz projektowania systemów z uwzględnieniem różnych dostępnych rozwiązań technicznych.
EN
The article presents a selected model of the operation process of the fire system (FSS). The developed fire scenario for the selected building object is possible for practical implementation only with the use of an appropriate functional structure FSS and technical devices from which the system is built with the appropriate reliability and technical parameters. Practical implementation of FSS in a transport facility is the use of elements, devices, fire panels, detectors, etc., which form a specific connection structure. The use of appropriate technical solutions in the system - redundancy, booking and the principle of safe damage causes that FSS has an optimal structure in terms of reliability. The article presents the selected technical structure of the FSS, which was described by means of the exploitation process graph, taking into account the actual damage intensities and the renewal times for selected devices included in the system. A constant intensity of damage was assumed in the FSS operation process due to the initial aging of individual devices that takes place in the production plant. The development of a model of exploitation process for selected operational states and a computer simulation of a selected FSS enables determination of reliability indicators.
PL
W artykule przedstawiono wybrany model procesu eksploatacji systemu sygnalizacji pożarowej (SSP). Opracowany scenariusz pożarowy dla wybranego obiektu budowlanego możliwy jest do realizacji tylko z zastosowaniem odpowiedniej struktury funkcjonalnej SSP i urządzeń technicznych z których zbudowany jest system. System powinien się posiadać odpowiednie parametry niezawodnościowo-techniczne. Realizacja praktyczna SSP w obiekcie to wykorzystanie elementów, urządzeń, central sygnalizacji pożarowej, czujek, itd., które połączone instalacją tworzą określoną strukturę o wyznaczonych relacjach przez projektanta. Stosowanie odpowiednich rozwiązań technicznych w systemie - tj. rezerwowania i zasady bezpiecznego uszkodzenia powoduje iż SSP posiada optymalną strukturę pod względem niezawodności. W artykule przedstawiono wybraną strukturę techniczną SSP, którą opisano za pomocą grafu procesu eksploatacji uwzględniając rzeczywiste intensywności uszkodzeń i czasy odnowy dla wybranych urządzeń które wchodzą w skład systemu. Założono stałą intensywność uszkodzeń w procesie eksploatacji SSP ze względu na wstępne starzenie poszczególnych urządzeń które ma miejsce w zakładzie produkcyjnym. Opracowany model procesu niezawodnościowo-eksploatacyjnego dla wybranych stanów i symulacja komputerowa w wybranej aplikacji umożliwiają wyznaczenie odpowiednich wskaźników użytkowania SSP.
PL
Do kompleksowej ochrony przeciwpożarowej w budynkach, gdzie wykorzystuje się serwerownie jako środek gaszenia pożaru, stosuje się system gaszenia gazem (SGG). Wtedy środek gaśniczy (gaz) należy przechowywać w miejscu, które określone jest przez opracowany scenariusz pożarowy. Wszystkie czynności mają na celu ugaszenie pożaru już w fazie początkowej. Centrala sygnalizacji pożaru (CSP) otrzymuje informację o pożarze z grupy czujek zlokalizowanych w ochranianym pomieszczeniu i jednocześnie wysyła powiadomienie do Państwowej Straży Pożarnej (PSP). Centrala podrzędna uruchamia samoczynnie proces gaszenia gazem. Dzięki wykorzystaniu takiego procesu powiadamiania i gaszenia pożaru powstaje system nadmiarowy. Powoduje to zwiększenie niezawodności systemu sygnalizacji pożaru (SSP), który jest odpowiedzialny za bezpieczeństwo w budynku.
EN
Fire protection of server rooms and data processing centres, located in public buildings, uses fire extinguishing equipment known as fixed gas fire extinguishing devices (SUG-G). The extinguishing medium (gas in tanks) should be stored at a location indicated in the fire scenario and in the technical contractor project for SUG-G. SUG-G is intended to extinguish a fire in its initial stages and to prevent fire spreading. The fire signalling central station (CSP) receives a fire signal from a group of sensors located in the protected premise and notifies the Fire Brigade (PS), whilst the fire extinguishing control room automatically starts the gas extinguishing process. Such use of a signalling and extinguishing system results in a redundant system. This improves reliability of the fire signalling system (SSP), which is responsible for safety inside the building.
PL
W artykule omówiono urządzenia (podzespoły wchodzące w skład systemu sygnalizacji pożarowej) służące do detekcji dymu, które można zastosować w celu zapewnienia bezpieczeństwa pożarowego wielkokubaturowych obiektów transportowych. W artykule omówiono zarówno powszechnie stosowane punktowe czujki dymu, czujki liniowe dymu, jak również bardziej zaawansowane technologicznie aspiracyjne czujki dymu (czujki zasysające) oraz czujki wykorzystujące nowoczesne technologie związane z wideo detekcją. Omówiono ponadto praktyczne możliwości w zastosowaniu konkretnych rozwiązań oraz ograniczenia w ich stosowaniu. Zaznaczono kierunki rozwoju systemów sygnalizacji pożarowej, w tym w zakresie detekcji dymu.
EN
The article discusses the possible types of smoke detection devices that can be used to provide fire safety for large volume transport facilities. The article discusses both commonly used point smoke detectors or line detectors, as well as more technologically advanced aspiration smoke detectors (aspiration detectors) and detectors using video detection. Practical possibilities in the application of specific solutions and limitations in their application were also discussed. Development directions of fire alarm systems producers, including smoke detection, have been marked.