Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Introduction: One of many procedures to control the quality of radiotherapy is daily imaging of the patient's anatomy. The CBCT (Cone Beam Computed Tomography) plays an important role in patient positioning, and dose delivery monitoring. Nowadays, CBCT is a baseline for the calculation of fraction and total dose. Thus, it provides the potential for more comprehensive monitoring of the delivered dose and adaptive radiotherapy. However, due to the poor quality and the presence of numerous artifacts, the replacement of the CBCT image with the corrected one is desired for dose calculation. The aim of the study was to validate a method for generating a synthetic CT image based on deformable image registration. Material and methods: A Head & Torso Freepoint phantom, model 002H9K (Computerized Imaging Reference Systems, Norfolk, USA) with inserts was imaged with CT (Computed Tomography). Then, contouring and treatment plan were created in Eclipse (Varian Medical Systems, Palo Alto, CA, USA) treatment planning system. The phantom was scanned again with the CBCT. The planning CT was registered and deformed to the CBCT, resulting in a synthetic CT in Velocity software (Varian Medical Systems, Palo Alto, CA, USA). The dose distribution was recalculated based on the created CT image. Results: Differences in structure volumes and dose statistics calculated both on CT and synthetic CT were evaluated. Discrepancies between the original and delivered plan from 0.0 to 2.5% were obtained. Dose comparison was performed on the DVH (Dose-Volume Histogram) for all delineated inserts. Conclusions: Our findings suggest the potential utility of deformable registration and synthetic CT for providing dose reconstruction. This study reports on the limitation of the procedure related to the limited length of the CBCT volume and deformable fusion inaccuracies.
2
Content available remote EPID – a useful interfraction QC tool
EN
Biomedical accelerators used in radiotherapy are equipped with detector arrays which are commonly used to obtain the image of patient position during the treatment session. These devices use both kilovolt and megavolt x-ray beams. The advantage of EPID (Electronic Portal Imaging Device) megavolt panels is the correlation of the measured signal with the calibrated dose. The EPID gives a possibility to verify delivered dose. The aim of the study is to answer the question whether EPID can be useful as a tool for interfraction QC (quality control) of dose and geometry repeatability. The EPID system has been calibrated according to the manufacturer’s recommendations to obtain a signal and dose values correlation. Initially, the uncertainty of the EPID matrix measurement was estimated. According to that, the detecting sensitivity of two parameters was checked: discrepancies between the planned and measured dose and field geometry variance. Moreover, the linearity of measured signal-dose function was evaluated. In the second part of the work, an analysis of several dose distributions was performed. In this study, the analysis of clinical cases was limited to stereotactic dynamic radiotherapy. Fluence maps were obtained as a result of the dose distribution measurements with the EPID during treatment sessions. The compatibility of fluence maps was analyzed using the gamma index. The fluence map acquired during the first fraction was the reference one. The obtained results show that EPID system can be used for interfraction control of dose and geometry repeatability.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.