In this paper a new approach for the detecting and locating different kinds of faults on power transmission lines using the concurrent neurofuzzy technique (CNF) is introduced. This approach relies on the advantages of combining fuzzy logic (FL) and the artificial neural network (ANN) to detect, classify and locate faults on a power transmission line that carries high voltage and very high voltage of 400 kV and 750 kV respectively over short distance and long distance of 120 km and 600 km respectively. Results exhibit that CNF is capable of detecting several and different fault types and locations with high accuracy, which will reduce the time for the technical team maintenance to achieve their goals.
PL
W artykule przedstawiono nowe podejscie do wykrywania i lokalizowania róznego rodzaju usterek w liniach elektroenergetycznych przy ˙ użyciu współbieżnej techniki neuro-rozmytej (CNF). Podejście to opiera się na zaletach połączenia logiki rozmytej i sztucznej sieci neuronowej w celu wykrywania, klasyfikowania i lokalizowania usterek w linii elektroenergetycznej, która przenosi wysokie napięcie i bardzo wysokie napięcie odpowiednio 400 kV i 750 kV w krótkim czasie odległośc i długa odległość odpowiednio 120 km i 600 km. Wyniki pokazują, ze CNF jest w stanie wykryć kilka różnych ˙ typów usterek i lokalizacji z dużą dokładnoscią, co skróci czas potrzebny zespołowi technicznemu na osiągnięcie celów.
2
Content available remote Nine-phase transmission line design: implementation using Matlab/Simulink
EN
This paper presents the design and the study of a nine-phase transmission line system. Two lines (400 kV over 200 km and 400 kV over 600 km) are implemented using Matlab/Simulink to solve problems of environmental damage caused by several lines located in the same place, the multiplicity of electric faults and the poor power capability transmitted of the three-phase systems. The results obtained show that nine-phase line system could connect up to 9.6 times more load than that of a three-phase line system.
PL
W artykule zaprezentowano projekt i analizę dziewięciofazowej linii przesyłowej. Analizowano dwie linie 400 kV – 200 km i 400 kV 600 km. Stosując Matlab/Simulink analizowano zakłócenie środowiska, możliwości powstawania błędów i możliwości przesyłania mocy. Wykazano że sieć dziewięciofazowa pozwala na obciążalność 9.6 razy większą niż sieć trójfazowa.