2
PL
W artykule zaprezentowano stanowisko dydaktycznego przydatne w laboratorium mechatroniki i przeznaczone do szkolenia w zakresie pneumatycznych układów napędowych oraz sterowania elektronicznego, elektrycznego i pneumatycznego, Omówiono możliwości budowy takich układów z gotowych elementów katalogowych o różnej konfiguracji, Przedstawiono przykład układu elektropneumatycznego, możliwego do zrealizowania na tym stanowisku.
EN
Doppler signals collected on the abdomen of the pregnant woman were submitted to the discrete wavelet transform using the db 10 wavelet. The wavelet reconstruction products were submitted to the autocorrelation analysis. The processing, supported with the ultrasonographic scanning enabled identification of the fetal periodic activities. The fetal pseudo-breathing movement velocity always falls in the range of 5-10 mm/s (Doppler frequency range 12.5-25 Hz), velocities of cardiac structures - in the range of 20-75 mm/s (Doppler frequency 50-200 Hz). The signals resulting from fetal displacements provoked by maternal breathing and cardiac action or fetal hiccup are expected not to adversely affect estimation of the fetal rhythms. These findings are important for the development of fetal monitoring systems.
5
Content available remote The fetal heart rate estimation based on continuous ultrasonic Doppler data
EN
Two methods to compute the fetal heart rate based on the analysis of Doppler signals obtained using continuous wave ultrasound were studied. The first uses bandpass filtering, directional signal separation and computation of the autocorrelation coefficient of the envelope of a single directional Doppler signal. The other uses discrete wavelet decomposition and reconstruction of a single directional signal with Daubechies db 10 wavelet family, with subsequent computation of the autocorrelation coefficient of the envelope of the reconstructed signal details for various scales. The results indicate that the discrete wavelet decomposition method is a suitable tool for fetal heart rate determination. It results in a more consistent fetal heart rate trace than the bandpass filtering approach.
PL
Referat opisuje szanse i zagrożenia dla małych i średnich przedsiębiorstw związane z wejściem Polski do Unii Europejskiej. Przedstawia wyniki badań przeprowadzonych w kraju i zagranicą (UC), cytuje publikacje Polskiej Agencji Rozwoju i Przedsiębiorczości związane z tym tematem. Dalsza część referatu to wyniki ekonomiczne małej inżynierskiej firmy zajmującej się hydrauliką i pneumatyką (Kret i S-ka) z kilku ostatnich lat, na podstawie których prezentuje własne podsumowanie i wnioski końcowe.
EN
The paper describes the chances and hazards for small and middle firms related to Poland. entry into European Union. There are presented the results of tests conducted at home and abroad (UC) and the publications of Polish Agency of Development and Initiative related to the subject under consideration. Further the paper refers to the economic effects from some last years, of a small engineering firm (KRET company) engaged in hydraulics and pneumatics and basing on this gives the final conclusions.
EN
Fetal motor activity (pseudobreathing movements, trunk and limb movements) and the fetal heart rate are important indicators of fetal well-being. The software developed using the LabVIEW environment processes in real time Doppler signals acquired from the CW fetal Doppler activity monitor via the PC sound card. Displacements of the structures, velocities and accelerations of these displacements as well as histograms of the velocities and accelerations are computed. The fetal heart rate and breathing movements are determined. The software performance was tested against ultrasonographic recordings. Four pregnancies were submitted to a 15-20 minutes long examination. The ultrasonographic images and Doppler quadrature data were taped simultaneously with Hi-Fi video recorder, then used as signal source for laboratory tests of the software. The movements detected with the software environment were compared with the concurrent USG images. The experiments show that the elaborated software is capable of detecting different kinds of fetal movements. Some artifacts, specifically those resulting from maternal movements, may be eliminated on the basis of their amplitude. The software is a promising diagnostic tool for obstetrics.
PL
Aktywność ruchowa płodu (ruchy pseudooddechowe, ruchy tułowia i kończyn) oraz rytm serca są ważnymi wskaźnikami stanu płodu. Oprogramowanie stworzone z użyciem środowiska LabVIEW przetwarza, w czasie rzeczywistym, sygnały dopplerowskie uzyskiwane z monitora aktywności ruchowej płodu z falą ciągłą przez kartę dźwiękową komputera PC. Wyznaczane są ruchy płodu, prędkości i przyśpieszenia tych ruchów, jak również histogramy prędkości i przyśpieszeń. Wykrywane są rytm serca płodu, jak również ruchy pseudooddechowe. Wyniki uzyskiwane przez oprogramowanie porównano z wynikami obserwacji ultrasonograficznej. Cztery przypadki ciąż bez powikłań zostały poddane 15-20 minutowemu badaniu. Obrazy ultrasonograficzne i kwadraturowe sygnały dopplerowskie były rejestrowane jednocześnie z użyciem magnetowidu Hi-Fi, następnie zostały użyte jako źródło sygnału podczas testów oprogramowania w warunkach laboratoryjnych. Opracowane oprogramowanie wykrywa różne rodzaje ruchów płodu. Niektóre zakłócenia, szczególnie te wynikające z ruchów matki, mogą być eliminowane w oparciu o ich amplitudę. Oprogramowanie jest obiecującym narzędziem w diagnostyce położniczej.
EN
Fetal motor activity and the fetal heart rate are important indicators of fetal well-being. The motor activity consist of pseudobreathing movements, trunk and limb movements. These movements can be detected using the ultrasonic Doppler method. The software developed using the LabVIEW environment processes in real time Doppler signals acquired via the PC sound card. Displacements of the structures, velocities and accelerations of these displacements as well as histograms of the velocities and accelerations are computed. Spectral analysis of the chest displacement signal allows determining the rhythm of pseudobreatching movements. The autocorrelation function is used to compute the fetal heart rate. The software was tested on simulated signals and real fetal Doppler signals.