The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.
EN
The presented article discusses the differences in the results of the electric field simulation in a medium voltage heat-shrinkable cable termination with the most probable assembly faults. Two types of voltage excitation were set as the boundary condition for a model of a real object. The first was a typical electrostatic excitation, and the second was the AC voltage with mains frequency. Both were used for cable accessories with selected assembly omissions. Consideration of the effect of the excitation type suggests that for cable accessories, field simulation using only electrostatics leads to unreal results and incorrect inference about the location of zones with the highest electrical stresses.
PL
Prezentowany artykuł omawia wpływ zadanego wymuszenia na różnice w wynikach symulacji pola elektrycznego w termokurczliwej głowicy kablowej średniego napięcia z najbardziej prawdopodobnymi błędami montażu. Przyjęto dwa rodzaje wymuszenia napięciowego jako warunek brzegowy w modelu bazującym na konstrukcji rzeczywistej głowicy. Pierwszym było typowe wymuszenie elektrostatyczne, a drugiem wymuszenie napięcia przemiennego. Oba zostały zastosowane dla osprzętu kablowego z wybranymi błędami montażu. Uwzględnienie wpływu typu wymuszenia sugeruje, że w przypadku osprzętu kablowego symulacja pola z zastosowaniem wyłącznie elektrostatyki prowadzi do nierzeczywistych wyników oraz błędnego wnioskowania co do lokalizacji stref o największych naprężeniach elektrycznych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.