The control of water quality in swimming pool is accomplished by treatment, including filtration and application of disinfectants. Contamination of pool water cannot be always effectively controlled by normal treatment. Swimming pool sediments were investigated previously and insufficient filtration efficiency for sand filters was noticed. In presented experiments two filtration medium materials were compared: silica sand and recycled glass (cullet). Results show, that despite larger negative zeta potential of cullet particles, filtration efficiency was comparable and recycled glass can be a useful material for optional filtration medium.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Two sediments resulting from swimming pool operation are characterized and the data discussed, namely the flocs which accumulated and were backwashed from deep bed filter, and bottom sediment collected from the pool by vacuum cleaner. Better understanding of sediments' structure and properties should allow for improvement of Cryptosporidium oocysts removal from pool water and as a consequence - increase the safety of pool users. Zeta potential, nano-size and micro-size of particles/flocs and derivatographic measurements were performed. The zeta potential data indicated easy flocculation and size distribution measurements revealed varied effectiveness of deep bed filtration. Derivatographic analysis indicated differences between sediments from filters backwashing and pool bottom sediments.
PL
Dwa rodzaje osadów pochodzących z instalacji basenowych zostały scharakteryzowane i otrzymane wyniki przedyskutowane, w szczególności flokuły, które zatrzymały się na filtrze piaskowo-żwirowym i następnie zostały usunięte w płukaniu zwrotnym oraz osady z dna niecki basenowej zebrane tzw. odkurzaczem wodnym. Lepsze zrozumienie struktury i właściwości osadów powinno usprawnić usuwanie cyst Cryptosporidium z basenów i w efekcie podnieść bezpieczeństwo kapiących się użytkowników. Przeprowadzono pomiary potencjału dzeta, rozkładu wielkości cząstek/flokuł w zakresach nano i mikro oraz pomiary derywatograficzne. Potencjał dzeta wskazał na łatwość flokulacji cząstek w układzie, a rozkłady wielkości ujawniły różnorodną efektywność filtracji. Analiza derywatograficzna wskazała na wyraźne różnice składu pomiędzy osadami z filtracji a osadami z dna basenu.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The effectiveness of water filtration in gravel-sand bed filters has been studied in the rehabilitating swimming pool treatment plant. Apart from instrumental analysis of the water the investigation considered additionally particle size distribution as well as thermal analysis of the sediment collected in the sand bed of depth filters and removed during the process of washing. Variable value of TOC in the washings for each filter indicates indirectly their non-uniform loading. It has been proved that the size of particles in the suspension easily changes as a result of operation of shear stress. Derivatographic research has indicated approximately 30 % presence of organic substances in the sediment. In neither of the investigated samples loss of mass over > 460oC has been observed.
PL
Przebadano efektywność filtracji wody w filtrach ze złożem żwirowo-piaskowym w instalacji basenu rehabilitacyjnego. Obok analizy instrumentalnej wody, w badaniach uwzględniono rozkład wielkości cząstek i analizę termiczną osadu zgromadzonego w złożu piaskowym filtrów wgłębnych i usuwanego podczas płukania. Zmienna wartość TOC w popłuczynach dla każdego z filtrów wskazuje pośrednio na nierównomierne ich obciążenie. Wykazano, że wielkość cząstek w zawiesinie łatwo zmienia się w wyniku działania naprężeń ścinających. Badania derywatograficzne wskazały na około 30% udział substancji organicznych w osadzie. W żadnej z badanych próbek, nie zanotowano ubytku masy powyżej > 460°C.