This paper presents the outcomes of tests of aggregates obtained from pulp and paper industry wastewater treatment using the electrocoagulation method. The test wastewater was treated on a laboratory scale with a recirculation system. Along with the wastewater treatment parameters, the fractal properties of the obtained aggregates were determined and their size was specified. The following wastewater parameters were tested: COD, turbidity and colour. For the conducted process, the fractal dimensions fell within the range of 1.30-1.70 at 0.1 A current. The applied current and electric charge flowing through the solution determined the efficiency of wastewater treatment, and impacted the structure, size and fractal dimensions of the obtained aggregates.
PL
W pracy przedstawiono efekty badań agregatów uzyskanych w wyniku oczyszczania ścieków celulozowo-papierniczych metodą elektrokoagulacji. Modelowe ścieki oczyszczano w laboratoryjnej skali, używając systemu recyrkulacyjnego. Wraz z wyznaczeniem parametrów oczyszczania ścieków określano właściwości fraktalne otrzymanych agregatów i oznaczano ich rozmiar. Badano takie parametry ścieków, jak: ChZT, mętność, barwę. Dla tego procesu uzyskane rozmiary fraktalne mieściły się w przedziale 1,30-1,72 przy natężeniu prądu 0,1 A. Zastosowane natężenie prądu oraz ładunek elektryczny przepływający przez roztwór wyznaczały efektywność oczyszczania ścieków i wpływały na strukturę, wielkość i rozmiar fraktalny otrzymanych agregatów.
2
Content available remote Computer simulation of chemical coagulation and sedimentation of suspended solids
EN
The computer program ZB2 was used to study simulated coagulation rate for the system containing spherical sol particles and spherical coagulant particles. The system performance was verified to the particle-cluster model of a fast and perikinetic coagulation process that fulfils Smoluchowski and/or Muller equations. The rate of the coagulation process satisfied both the kinetic equation of a first-order reaction and a second-order reaction. However, chosen concepts and models in the theory of bidispersive sol coagulation have been negatively verified. Also, attempts have been made to modify the Muller integral equation for selected boundary conditions.
EN
Coagulation is an important process used in water and sewage treatment. Because of its complexity and many factors affecting its speed and efficiency, there is a need for continuous research of a fundamental as well as a utilitarian nature. The kinetics of the coagulation process is still not fully investigated or explained. This is due to the limitations of laboratory experiments, in contrast to computer simulation, which offers practically unlimited experimental possibilities. This paper presents the results of research carried out using a computer program simulating the coagulation of a suspension containing spherical particles of sol and spherical particles of coagulant. The effect of excess and deficiency of coagulant on the formation time of the first flock was identified. The influence of parameters such as the concentration of sol, size of coagulant particles, and the initial velocity of sol and coagulant was analysed. The study revealed that both deficiency and excess of the used coagulant decreased the rate of the coagulation process. It was also found that an increase in the simulated initial velocity of the sol (mixing), as well as the increase in the particle diameter and concentration of the sol increased the speed of sol destabilisation.
PL
Koagulacja jest istotnym procesem stosowanym w oczyszczaniu wody i ścieków. Jest to proces złożony, wiele czynników wpływa na jego szybkość i efektywność. Stąd wynika potrzeba ciągłych badań natury zarówno fundamentalnej, jak i utylitarnej. Kinetyka procesu koagulacji ciągle pozostaje nie do końca zbadana i wyjaśniona. Wynika to z ograniczeń w obszarze laboratoryjnego eksperymentowania, w przeciwieństwie do symulacji komputerowej, która praktycznie stwarza nieograniczone możliwości eksperymentalne. W pracy przedstawiono wyniki badań przeprowadzonych przy zastosowaniu programu komputerowego symulującego koagulację zawiesiny zawierającej kuliste cząstki zolu i kuliste cząstki koagulantu. Określono wpływ nadmiaru i niedomiaru koagulantu na szybkość tworzenia pierwszego kłaczka. Badano wpływ takich parametrów, jak stężenie zolu, rozmiar koagulantu, prędkość początkowa koagulantu i zolu. Stwierdzono, że zarówno niedomiar, jak i nadmiar stosowanego koagulantu powodował obniżenie szybkości procesu koagulacji. Stwierdzono także, że wzrost symulowanej prędkości początkowej zolu (mieszanie), wzrost średnicy i stężenia zolu powodował wzrost prędkości destabilizacji zolu.
EN
The results of municipal wastewater treatment by chemical coagulation with PIX and electrocoagulation in a recirculation system with aluminum electrodes were discussed and interpreted. Those processes were analyzed as: a) preliminary processing before biological treatment, or b) the only treatment procedure. The results of chemical coagulation and electrocoagulation indicate that both methods guarantee the required level of phosphorus and suspended solids removal from wastewater. Despite the above, the COD of treated wastewater decreased to only 200 mg×dm–3 which exceeds the norm for effluents discharged from treatment plants (125 mg×dm–3). Our results indicate that municipal wastewater treatment cannot rely solely on chemical coagulation and/or electrocoagulation. In successive parts of the study, wastewater was treated with significantly smaller doses of a ferric coagulant (PIX) and an aluminum electrocoagulant (Al electrodes). The above treatments lowered the phosphorus load of wastewater to a level ensuring its nearly complete removal in successive stages of biological treatment. The practical application of the resulting database was evaluated in view of the existing regulations as well as more stringent requirements which could be introduced in the future, in particular with regard to total phosphorus loads.
PL
W pracy opisano i zinterpretowano rezultaty procesów oczyszczania ścieków miejskich koagulowanych chemicznie PIX-em oraz elektrokoagulowanych recyrkulacyjnie na elektrodach glinowych. Procesy te potraktowano jako: a) etap wstępny, przed biologicznym oczyszczaniem badanych ścieków oraz b) jedyne i ostateczne oczyszczanie ścieków. Wyniki badań procesu koagulacji chemicznej oraz elektrokoagulacji badanych ścieków pokazały, że metody te zapewniają wymagany poziom usunięcia zawiesin i fosforu z oczyszczanych ścieków. Jednakże ChZT tak oczyszczonych ścieków obniżało się tylko do ok. 200 mg·dm–3 przy wymaganym poziomie 125 mg·dm–3 w odpływie z oczyszczalni. Fakt ten nie pozwala więc traktować koagulacji chemicznej lub/i elektrokoagulacji jako jedynego i ostatecznego etapu oczyszczania badanych ścieków miejskich. Stąd w dalszej części badań ścieki traktowano znacznie mniejszymi dawkami koagulantu żelazowego (PIX) i elektrokoagulantu glinowego (elektrody Al). Prowadziło to do częściowego usunięcia fosforu, zapewniając takie obniżenie poziomu P, aby kolejny etap biologicznego oczyszczania mógł zapewnić stężenie tego biogenu w odpływie bliskie zeru. Dokonano oceny wartości aplikacyjnej uzyskanej bazy danych w świetle aktualnych norm i uwarunkowań, jak również w szerszej perspektywie zaostrzenia wymagań w zakresie stopnia oczyszczenia ścieków, szczególnie w zakresie usuwania fosforu.
5
Content available remote Destabilization of model wastewater in the chemical coagulation process
EN
This paper discusses the results of laboratory analyses of the coagulation and flocculation of model wastewater. The investigated wastewater was susceptible to treatment by chemical coagulation. The effectiveness of two commercial coagulants, PAC produced at the DEMPOL-ECO Chemical Plant and PIX manufactured by KEMIPOL, was compared. A mathematical model relying on a second-degree polynomial was used to describe and analyze experimental data. In each case, the parabola minimum point was a precisely determined coagulant dose, regarded as the optimal dose. The application of a coagulant dose higher than the optimal dose reduced the effectiveness of wastewater treatment by coagulation. A detailed analysis of turbidity, suspended solids, total phosphorus and pollutant removal measured by the COD test revealed that PAC was a more effective and a more efficient coagulant than PIX. The risk of coagulant overdosing was greater with the use of PAC than PIX.
PL
W niniejszej pracy przedstawiono, opisano i zinterpretowano wyniki badań laboratoryjnych procesu koagulacji-flokulacji ścieków modelowych. Zastosowane ścieki modelowe okazały się podatne na oczyszczanie metodą koagulacji chemicznej. Zastosowano i porównano dwa komercyjne koagulanty: PAC - wyprodukowany w zakładach chemicznych DEMPOL-ECO oraz PIX - wyprodukowany przez firmę KEMIPOL. Do przedstawienia i analizy uzyskanej bazy danych doświadczalnych z powodzeniem zastosowano model matematyczny w postaci wielomianu drugiego stopnia. Minimum takiej paraboli każdorazowo stanowiła dawka koagulantu precyzyjnie obliczana i traktowana jako dawka optymalna. Zastosowanie wyższej, aniżeli optymalna, dawki koagulantu prowadziło każdorazowo do obniżenia stopnia oczyszczenia koagulowanych ścieków. Szczegółowa analiza wyników usuwania mętności, zawiesin, fosforu ogólnego i zanieczyszczeń określanych w skali ChZT pokazała, że PAC skuteczniej i wydajniej, aniżeli PIX, koagulował badane ścieki modelowe. Jednakże zagrożenie tzw. przedawkowania koagulantu okazało się większe ze strony PAC-u aniżeli przy wykorzystaniu PIX-u.
PL
Przedstawiono wyniki badań szybkości koagulacji komputerowo symulowanego układu zawierającego kuliste cząstki zolu i kuliste cząstki koagulantu. Ilościowe proporcje tych dwóch rodzajów cząstek każdorazowo spełniały warunek komputerowo symulowanego „progu koagulacji”, który pozostawał zbliżony do realiów praktycznych np. w oczyszczalni ścieków. Przetestowano wyniki badań kinetycznych w świetle klasycznych równań Smoluchowskiego i Müllera. Wyniki tej grupy badań umożliwiły między innymi negatywną weryfikacji niektórych poglądów i schematów w zakresie teorii koagulacji zolu bidyspersyjnego. Dla wybranych warunków granicznych przeprowadzono wstępne próby modyfikacji wzoru Müllera.
EN
This study investigated the coagulation rate of a computer-simulated system comprising spherical sol particles and spherical coagulant particles. The quantitative proportions of both particle types satisfied the computer-simulated “coagulation threshold” which remained similar to that observed in natural systems, such as wastewater treatment plants. The results of kinetic tests have been tested in view of first-order and second-order reactions as well as classical Smoluchowski and Müller equations. The results noted in this group of tests supported the negative verification of selected methods and concepts in the theory of bidispersive sol coagulation. Attempts were made to modify the Müller equation for selected boundary conditions.
PL
W niniejszej pracy przedstawiono, opisano i zinterpretowano wyniki badań laboratoryjnych procesu koagulacji-flokulacji ścieków modelowych. Zastosowane ścieki modelowe okazały się podatne na oczyszczanie metodą koagulacji chemicznej. Zastosowano i porównano dwa komercyjne koagulanty: PAC - wyprodukowany w zakładach chemicznych DEMPOL-ECO oraz PIX - wyprodukowany przez firmę KEMIPOL. Do przedstawienia i analizy uzyskanej bazy danych doświadczalnych z powodzeniem zastosowano model matematyczny w postaci wielomianu drugiego stopnia. Minimum takiej paraboli każdorazowo stanowiła dawka koagulantu precyzyjnie obliczana i traktowana jako dawka optymalna. Zastosowanie wyższej, aniżeli optymalna, dawki koagulantu prowadziło każdorazowo do obniżenia stopnia oczyszczenia koagulowanych ścieków. Szczegółowa analiza wyników usuwania mętności, zawiesin, fosforu ogólnego i zanieczyszczeń określanych w skali ChZT pokazała, że PAC skuteczniej i wydajniej, aniżeli PIX, koagulował badane ścieki modelowe.
EN
This paper discusses the results of laboratory analyses of the coagulation and flocculation of model wastewater. The investigated wastewater was susceptible to treatment by chemical coagulation. The effectiveness of two commercial coagulants, PAC produced at the DEMPOL-ECO Chemical Plant and PIX manufactured by KEMIPOL, was compared. A mathematical model relying on a second-degree polynomial was used to describe and analyze experimental data. In each case, the parabola minimum point was a precisely determined coagulant dose, regarded as the optimal dose. The application of a coagulant dose higher than the optimal dose reduced the effectiveness of wastewater treatment by coagulation. A detailed analysis of turbidity, suspended solids, total phosphorus and pollutant removal measured by the COD test revealed that PAC was a more effective and a more efficient coagulant than PIX.
8
Content available Symulacja komputerowa procesu koagulacji
PL
Przedstawiono wyniki badań przeprowadzonych przy zastosowaniu komputerowego programu „ZB2” symulującego koagulację zawiesiny zawierającej kuliste cząstki zolu i kuliste cząstki koagulantu. Zaprezentowano charakterystykę opracowanego programu, a następnie opisano wyniki badań wpływu prędkości początkowej zolu oraz rozmiarów cząstki zolu i koagulantu na szybkość procesu koagulacji. Wykazano, iż program „ZB2” pozostaje w zgodności z klasycznymi teoriami ruchu cząstek i destabilizacji układów koloidalnych. Szybkość symulowanego procesu koagulacji, w zakresie opisanym w niniejszej pracy, spełniała równanie kinetyczne II rzędu, a także równanie Smoluchowskiego. Symulowany wzrost prędkości początkowej cząstek zolu zgodnie z oczekiwaniem powodował wzrost szybkości koagulacji. Okazało się także, że większy wpływ na szybkość koagulacji miało zwiększenie średnicy cząstki zolu aniżeli zwiększenie średnicy cząstki koagulantu.
EN
This paper presents some results of the study carried out with using “ZB2” ie a computer program for coagulation simulating of system containing the spherical particles of suspension and spherical particles of coagulant. The description of the program is followed by an analysis of the effect of the initial velocity of sol particles and also the effect of colloidal particle size and coagulant particle size on the rate of the coagulation examined. It was demonstrated that the tested program is consistent with some classical theories of particle motion and destabilization of the colloidal systems. The rate of the simulated coagulation process, within the range described in this study, satisfies both kinetic equations of second-order reactions and the Smoluchowski equation. An increase the initial velocity simulated of the coagulant particle is, according to expectation, followed by the increase the simulated rate of coagulation. It also found that a greater impact on the coagulation rate has the diameter increasing of the sol particles than the diameter increasing in coagulant particles.
PL
W niniejszej pracy przedstawiono wyniki elektrochemicznego oczyszczania ścieków celulozowo-papierniczych. Elektrolizę prowadzono w układzie statycznym z użyciem elektrod glinowych. Badania prowadzono przy dwóch wartościach gęstości prądu na elektrodach: 3,125 i 6,25 mA/cm2. Po elektrokoagulacji i sedymentacji mierzono w roztworze ChZT, mętność, barwę oraz zawiesiny. Jednocześnie określono właściwości fraktalne otrzymanych agregatów-kłaczków osadu ściekowego i oznaczono ich rozmiary fraktalne.
EN
Results of the electrochemical treatment of pulp and paper wastewater have been described in this paper. The electrolysis was conducted in static system on aluminium electrodes. The wastewater purification was carried out at two values of the current density 3.125 and 6.25 mA/cm2. After electrocoagulation the COD, turbidity, suspended solids and color of the supernatant were measured. The fractal dimension of the aggregates-flocs of the sludge obtained was determined too.
EN
Results of the electrochemical treatment of pulp and paper wastewater have been described. The electrolysis was conducted in static system on aluminium electrodes. The wastewater purification was carried out at two values of the current density 3.125 mA/cm2 and 6.25 mA/cm2. After electrocoagulation the COD, turbidity, suspended solids and color of the supernatant were measured. The fractal dimension of the aggregates-flocs of the sludge obtained was determined, too. The examined process of statical electrocoagulation turned out to be an efficient method for pulp and paper wastewater purification. The aggregates-flocs measured were recognized as self-simil objects.
PL
W niniejszej pracy przedstawiono wyniki elektrochemicznego oczyszczania ścieków celulozowo- -papierniczych. Elektrolizę prowadzono w układzie statycznym, z użyciem elektrod glinowych. Badania prowadzono przy dwóch wartościach gęstości prądu na elektrodach 3,125 mA/cm2 i 6,25 mA/cm2. Po elektrokoagulacji i sedymentacji mierzono w roztworze ChZT, mętnosć, barwę oraz zawiesiny. Jednoczesnie określono właściwości fraktalne otrzymanych agregatów-kłaczków osadu ściekowego i oznaczono ich rozmiary fraktalne. Badany proces elektrokoagulacji okazał się skuteczną metodą oczyszczania ścieków celulozowo-papierniczych. Badane agregaty-kłaczki były obiektami „samopodobnymi”.
EN
In the present study, a computer program was employed to simulate the coagulation of suspended solids. The paper provides a description of the developed simulation program. The reaction order of the coagulation process was determined, and the effect of the initial velocity of sol particles and the size of sol and coagulant particles on the rate of coagulation was investigated. The tested program was found to comply with the classical theories of particle motion and colloidal system destabilization. The rate of the simulated coagulation process satisfied second-order kinetic equations and the Smoluchowski equation. As expected, a simulated increase in the initial velocity of sol particles increased the rate of coagulation. An increase in the sol particle diameter had a more significant effect on the rate of coagulation than an increase in the coagulant particle diameter.
PL
Opisano wyniki badań przeprowadzonych przy zastosowaniu komputerowego programu „ZB2” symulującego koagulację zawiesiny zawierającej kuliste cząstki zolu i kuliste cząstki koagulantu. Przedstawiono charakterystykę opracowanego programu, a następnie opisano wyniki badań wpływu prędkości początkowej zolu oraz rozmiar cząstki zolu i koagulantu na szybkość procesu koagulacji. Wykazano, iż program „ZB2” pozostaje w zgodności z klasycznymi teoriami ruchu cząstek i destabilizacji układów koloidalnych. Szybkość symulowanego procesu koagulacji, w zakresie opisanym w niniejszej pracy, spełniała równanie kinetyczne II rzędu, a także równanie Smoluchowskiego. Symulowany wzrost prędkości początkowej cząstek zolu zgodnie z oczekiwaniem powodował wzrost szybkości koagulacji. Okazało się także, że większy wpływ na szybkość koagulacji miało zwiększenie średnicy cząstki zolu, aniżeli zwiększenie średnicy cząstki koagulantu.
12
Content available Statyczna elektrokoagulacja ścieków modelowych
PL
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const), oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-elektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
EN
This paper presents the results of electrochemical treatment of model wastewater. Parameters and results of electrolytic treatment of the model wastewater under chronopotentiometric (CHRP) conditions, ie at constant current (I = const), and under chronoamperomtric (CHRA) conditions, ie at constant voltage (U = const), were compared in the study. Electrolysis was performed in a static system, using an electrolyser with aluminium electrodes. Six-electrode (three cathodes and three anodes) electrolyzers were applied. Chemical oxygen demand (COD), color, turbidity, suspended solids and total phosporus concentration were measured after electrocoagulation and sludge sedimentation. The process of static electrocoagulation was found to be an effective method for model wastewater treatment.
EN
This study presents the results of electrochemical treatment of model wastewater. It compares the parameters and the results of wastewater electrolysis performed by chronopotentiometric electrocoagulation (CHRP) at constant current intensity (I = const) and chronoamperometric electrocoagulation (CHRA) at constant voltage (U = const). Electrolysis was carried out in a static system with the use of an electrolyzer with aluminum electrodes. A six-electrode electrolyzer (three cathodes and three anodes) was applied. The chemical oxygen demand (COD), turbidity, color intensity, suspended solids and total phosphorus concentration of the solution were determined after electrocoagulation and sludge sedimentation.
PL
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const) oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-eIektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
14
Content available remote Colloidal sorbents wastewater coagulation
EN
Coagulation performance of PAC, Al2(SO4)3 and PIX in model wastewater was compared. For aluminium coagulants the proposed hypothesis that the amount of a coagulant has to be precisely determined based on the condition of the minimum of the parabola dx = 0 was confirmed. It was found that the dose of PIX should be calculated using the coordinates of the point of intersection of appropriate straight lines. Then under conditions of an optimum coagulant dose the mechanism of phosphorus removal from model wastewater was examined. The determination coefficient R2 for a converted eąuation of the Langmuir adsorption isotherm indicated chemical naturę of phosphate(V) binding by colloidal micelles of {Al(OH)3} and{FeCOH)3}.
PL
Porównano zdolność koagulacyjną PAC, Al2(SO4)3 i PDC w ściekach modelowych. Dla koagulantów glinowych potwierdzono słuszność nowej koncepcji dokładnego obliczania ilości koagulantu z warunku minimum paraboli dx = 0. Stwierdzono, że dawkę PK należy obliczać ze współrzędnych przecięcia odpowiednich prostych. W warunkach „dawki optymalnej" koagulantu badano mechanizm usuwania fosforu L koagulowanych ścieków modelowych. Wartości współczynnika determinacji R2 dla skonwertowanego równania izotermy adsorpcji Langmuira wskazały na chemiczny charakter wiązania fosforanów(V) przez koloidalne micele {Al(OH)3} i {Fe(OH)3}.
15
Content available remote Computer simulation of wastewater flocculation
EN
The paper presents the results of studies conducted using a computer program "ZB" simulating wastewater suspension destabilization. Parameters of this program are also discussed. The system performance was positively verified against a classical theory of the kinetics and diffusion of dispersoids. It was found that the program "ZB" works in accordance with logic and general principles of colloidal system destabilization. This confirms that it can be successfully applied to theoretical research on the so-called latent coagulation as well as to practical calibration and use under technological conditions, e.g., at a sewage treatment plant. It follows that the above computer simulation can be a viable alternative to laboratory tests whose results are not always fully reliable and accurate.
PL
Opisano wyniki badań, które przeprowadzono, stosując komputerowy program "ZB" symulujący destabilizację zawiesin ściekowych. Przedstawiono charakterystykę opracowanego programu, a następnie pozytywnie zweryfikowano jego funkcjonowanie w świetle klasycznej teorii kinetyki i dyfuzji dyspersoidów. Stwierdzono, że program ZB działa zgodnie z logiką i ogólnymi zasadami procesu destabilizacji układów koloidalnych, wskazując na duże możliwości jego wykorzystania zarówno do teoretycznych badań etapu tzw. koagulacji skrytej, jak i do praktycznego "wykalibrowania" i użycia w warunkach technologicznych, np. w oczyszczalni ścieków. W świetle uzyskanych wyników badań metodę symulacji komputerowej uznano za realną alternatywę nie zawsze wystarczająco wiarygodnych i precyzyjnych badań laboratoryjnych.
EN
The application of the computer program ZB2 simulating chemical coagulation was presented. The effects of the settling rate (F) and the initial velocity of coagulant particles (C) on the rate of coagulation-flocculation were determined for different values of the ratio (1) between the mass of a coagulant particle and the mass of a suspended particle. Results are illustrated in Figures in the form of parabolas. It was found that a twofold increase in the initial velocity of coagulant particles and a twofold increase in the ratio between the mass of a coagulant particle and the mass of a suspended particle caused a decrease in the optimal value of the settling rate (F), which determines the rate of particle elimination from the system.
PL
Wspomaganie procesu biologicznego oczyszczania ścieków metodą koagulacji chemicznej bardzo często okazuje się najskuteczniejszym sposobem zapewnienia wymaganego poziomu biogenów w odpływie. Wynika stąd potrzeba ciągłych badań nad złożonym procesem destabilizacji układów koloidowych. Bardzo duże możliwości badawcze daje symulacja komputerowa, która stwarza praktycznie nieograniczone możliwości eksperymentalne. W tej pracy przedstawiono wyniki aplikacji komputerowego programu ZB2 symulującego koagulację chemiczną. Określono wpływ wartości współczynnika opadania F oraz prędkości początkowej cząstek koagulantu C na szybkość koagulacji - flokulacji, przy różnych wartościach stosunku masy cząstki koagulantu do masy cząstki zanieczyszczenia I. Uzyskane wyniki przedstawiono na wykresach w postaci odpowiednich paraboli. Zaobserwowano, że dwukrotne zwiększenie prędkości początkowej cząstek koagulantu C i dwukrotne zwiększenie stosunku masy cząstek koagulantu do masy cząstek zawiesiny prowadziło do zmniejszenia optymalnej wartości współczynnika opadania F, który determinuje szybkość "wypadania" cząstek z układu.
17
Content available remote Fractal characteristics of post-coagulation sludge from sewage
EN
Aggregates obtained as a result of chemical coagulation of municipal sewage were studied. Fractal dimension D ranging from 1.71 to 1.92 of 1300 measured aggregates at mean determination coefficient r2 = 0.949 was calculated. An effect of the type of coagulant, dose and "age" of the aggregates on D was examined and explained. Fractal dimension has appeared a powerful tool in the investigation of the struc-ture and composition of sludge aggregates. This tool was sensitive enough to indicate even such subtle changes as sludge ageing or coagulant overdosing.
PL
Badano agregaty otrzymane w wyniku chemicznej koagulacji ścieków komunalnych. Rozmiar fraktalny otrzymanych agregatów mieścił się w granicach D = 1,71-1,92 przy średnim współczynniku determinacji r2 = 0,949. Rozmiar fraktalny okazał się ważnym kryterium oceny struktury osadu pokoagulacyjnego, zależnym od dawki, rodzaju koagulanta oraz "wieku" agregatów.