Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Within this study, the usefulness of different zeolites, such as natural clinoptilolite from Ukraine, synthetic zeolites manufactured by Soda Works of Inowrocław, and zeolites obtained in the laboratory on the basis of fly ashes has been verified and compared as the adsorbents of CO2 from a model mixture of flue gas. The adsorption capacity of carbon dioxide was examined at different temperatures and at different velocity of the gas mixture flowing through an adsorption bed. The obtained results have enabled the assumption to be put forward that the use of cheap natural clinoptilolite and zeolites synthesized on the basis of fly ashes may prove very useful for removing carbon dioxide, being competitive, at the same time, to the predominatly used synthetic zeolites.
PL
W artykule dokonano wstępnego sprawdzenia i porównania przydatności różnego typu zeolitów: naturalnego klinoptilolitu, zeolitów syntetycznych, laboratoryjnie otrzymanych zeolitów na bazie popiołów lotnych - jako adsorbentów CO2 z modelowej mieszaniny gazów odlotowych. Zdolność adsorbcji dwutlenku węla przez zeolity zbadana została w różnych temperaturach i przy różnych prędkościach przepływu mieszaniny gazów przepływającej przez zlóża adsorpcyjne.
2
Content available remote Comparison of two methods for (sup 226)Ra determination in mineral water
EN
(sup 226) Ra concentration in bottled mineral water has been determined by a liquid scintillation technique (LSC) with the separation of α from β pulses. Extraction of radon from 0.5 dm3 of water samples to 20 ml of a xylene based scintillation cocktail is sufficient for the determination of (sup 226)Ra concentrations above12 mBq/dm3 (with ±10% error). A lower (sup 226)Ra concentration (from 2.2 mBq/dm3) can be measured after preliminary co-precipitation of (sup 226)Ra with calcium phosphate at pH = 10 from 1.5 dm3 water samples. The obtained precipitates were dissolved with HCL solution directly in the scintillation vials and then the xylene based scintillation cocktail was added. The activity was measured after reaching a (sup 226)Ra - (sup 222)Rn equilibrium and the removal of water. Where as the (sup 226)Ra determination limit for the simple extraction method is not sufficient for some mineral water samples, the second more laborious method can be applied for (sup 226)Ra determination even in tap waters. From the examined mineral water available on the local market only in one case did the (sup 226)Ra activity exceed the limit of 100 mBq/dm3 for the total α activity in the bottled mineral waters.
PL
Stężenie (sup 226)Ra w butelkowanych wodach mineralnych oznaczano techniką ciekłej scyntylacji z separacją impulsów α od β. Prosta ekstrakcja równowagowego (sup 222)Rn z próbek wody o objętości 0.5 dm3 do 20 mi scyntylatora ksylenowego pozwala na oznaczanie poziomów (sup 226)Ra wyższych od 12 mBq/dm3 (z błędem ±10%). Niższe stężenia (>2.2 mBq/dm3) można mierzyć po wstępnym zatężeniu (sup 226Ra) przez współstrącanie z fosforanem wapnia z próbki wody o objętości 1.5 dm3 przy pH = 10. Otrzymany osad rozpuszczano w stężonym HCI bezpośrednio w naczynkach scyntylacyjnych. Następnie dodawano do nich 10 mi scyntylatora ksylenowego. Aktywność (sup 222)Rn i produktów jego rozpadu mierzono po ustaleniu się równowagi (sup 226)Ra - (sup 222)Rn i usunięciu warstwy wodnej. Metoda ta pozwala oznaczyć zawartość 226Ra również w wodach otwartych oraz w wodzie wodociągowej. Tylko w jednej wodzie mineralnej stwierdzono przekroczenie dopuszczalnego limitu całkowitej aktywności a wynoszącego 100 mBq/dm3.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.