The paper presents the modeling of transmission of the ultrasonic plane wave through an uniform liquid layer. The considered sources of the ultrasonic wave were normal (straight) beam longitudinal wave probes and angle beam sheer waves probes commonly used in non-destructive testing. Coupling losses (CL) introduced by the presence of the coupling layer are discussed and determined applying the numerical procedure. The modeling applies to both monochromatic waves and short ultrasonic pulses with a specified frequency bandwidth. Model implementation and validation was performed using a specialized software. The predictions of the model were confirmed by coupling losses measurements for a normal beam longitudinal wave probe with a delay line made of polymethyl methacrylate (PMMA). The developed model can be useful in designing ultrasonic probes for high-speed rail track inspections, especially for establishing the optimal thickness of the water coupling layer and estimation of coupling losses, due to inevitable changes of the water gap during mobile rail inspection.
2
Content available remote Procesy degradacji w elementach tekstolitowych ograniczników przepięć
PL
W pracy przedstawiono wyniki badań próbek tekstolitowych elementów osłonowo-centrujących z eksploatowanych ograniczników przepięć SN. Prądy wyładowcze (zwarciowe) o zróżnicowanym natężeniu i czasie trwania spowodowały w tworzywie elementów efekty degradacji o różnym stopniu zaawansowania, które badano z wykorzystaniem metod mikroskopowych i mikroanalizy rentgenowskiej EDS. Udokumentowano zmiany w składzie elementarnym (zawartości pierwiastków) warstwy wierzchniej tworzyw tekstolitowych - w miarę postępu efektów degradacji. Wykazano, że tworzywa te posiadają niewystarczającą odporność na skutki awaryjnej pracy ogranicznika przy jego zawilgoceniu, które jest konsekwencją rozszczelnienia osłony.
EN
The work describes degradation effects in the structure of textolite shield-centering elements of operated MV surge arresters. As a result of acting inner partial discharges of diverse duration and power - the material underwent degradation of different degree of advancement. Using microscopic research techniques and EDS analysis, the authors found and documented changes of structure and chemical composition of the material surface, with the increasing degree of degradation. It has been shown that textolite materials have insufficient resistance to the effects of emergency operation of the arresters after moisture ingress, which is a consequence of unsealing of the housing.
EN
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
PL
Celem prezentowanej pracy było znalezienie zależności pomiędzy parametrami mikrostruktury warystorów, a prądem płynącym przez ogranicznik przepięć dla różnych poziomów napięcia. Badania zostały wykonane na losowo wybranej populacji beziskiernikowych ograniczników przepięć w osłonach polimerowych, przeznaczonych do pracy w sieci średniego napięcia. Wykonano pomiary przebiegów referencyjnych dla badanej populacji ograniczników. Przyjęto jako kryterium oceny udział wyższych harmonicznych w przebiegu prądu. Praca stanowi wstęp do szerszego zakresu badań, prowadzonych w ramach wspólnych działań laboratoriów Instytutu Energetyki i Instytutu Podstawowych Problemów Techniki PAN.
EN
The purpose of the presented work was to find the relationship between the varistor's microstructure parameters and the current flowing through the surge arrester for different voltage levels. The tests were performed on a randomly selected population of non-spark surge arresters in polymeric shields intended for operation in medium voltage networks. The reference waveforms were measured for the tested population. Higher harmonics participation in the current wave was assumed as the evaluation criterion. The work is an introduction to a wider range of research carried out as part of joint activities of the laboratories of the Institute of Power Engineering and the Institute of Fundamental Technological Research PAN.