This paper discusses power flow control algorithm in a microgrid with battery energy storage system. Depending on the state of charge of the storage and the power difference between generation and load, the storage operates in charge or discharge modes adjusting the instantaneous power. The goal is to obtain exchange power changes with the distribution system according to a pre-set curve. The system is simulated in MATLAB. The results show the effectiveness of the proposed control algorithm.
PL
W artykule zaproponowano algorytm sterowania przepływem mocy w mikrosieci z akumulatorowym zasobnikiem energii. W zależności od stanu naładowania magazynu i różnicy mocy między generacją a obciążeniem, zasobnik operuje w trybach ładowania lub rozładowywania dostosowując moc chwilową. Celem jest uzyskanie zmian mocy wymiany z systemem nadrzędnym według zadanej krzywej. Mikrosieć jest symulowana w środowisku MATLAB. Wyniki pokazują skuteczność proponowanego algorytmu sterowania.
This paper presents the application of an improved ant colony optimization algorithm called mixed integer distributed ant colony optimization to optimize the power flow solution in power grids. The results provided indicate an improvement in the reduction of operational costs in comparison with other optimization algorithms used in optimal power flow studies. The application was realized to optimize power flow in the IEEE 30 and the IEEE 57 bus test cases with the objective of operational cost minimization. The optimal power flow problem described is a non-linear, non-convex, complex and heavily constrained problem.
Load flow studies are carried out in order to find a steady state solution of a power system network. It is done to continuously monitor the system and decide upon future expansion of the system. The parameters of the system monitored are voltage magnitude, voltage angle, active and reactive power. This paper presents techniques used in order to obtain such parameters for a standard IEEE – 30 bus and IEEE-57 bus network and makes a comparison into the differences with regard to computational time and effectiveness of each solver.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper deals with load flow analysis of local microgrid containing a stochastic renewable energy source and storage. The study is carried out using the Matpower toolbox with all relevant constraints considered regarding storage, power lines and other components. Certain operational scenarios of the microgrid are also discussed.
PL
Niniejszy artykuł dotyczy analizy rozpływu mocy w lokalnej mikrosieci zawierającej stochastyczne odnawialne źródło energii i magazynowan energii. Analizę przeprowadzono przy użyciu zestawu narzędzi Matpower ze wszystkimi istotnymi ograniczeniami w odniesieniu do magazynu energii, linii energetycznych i innych komponentów. Omówiono również niektóre scenariusze operacyjne mikrosieci.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.