Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Investigation of filligree (U)HPC-facades with an innovative experiment set-up
EN
With a new innovative experiment set-up it is possible to examine the multiaxial load bearing behaviour of whole facade systems made of (U)HPC under realistic conditions. The 3D-deformation-analysis delivers deformation data, which can be compared with FE-Models to check the plausibility. Few facades of artificial stone were tested. The failure load was used to recalculate the bending tensile strength with two different approaches. The results show that there are available reserves in the system and that the results deviate clearly from the results of uniaxial testing. The utilization of these reserves would lead to more economical facade systems and to a reduction of transmission heat losses, because the number of fastener and therefore thermal bridges would be reduced.
PL
Z nową innowacyjną konfiguracją stanowiska badawczego możliwe jest zbadanie wieloosiowego zachowania całych systemów elewacyjnych wykonanych z B(U)WW w rzeczywistych warunkach. Dane uzyskane z trójwymiarowych analiz deformacji można porównać z modelami ES, aby sprawdzić ich wiarygodność. Przetestowano kilka elewacji z kamienia sztucznego. Obciążenie niszczące było używane do przeliczenia wytrzymałości na rozciąganie przy zginaniu z dwóch różnych podejść. Wyniki pokazują, że w systemie istnieją rezerwy nośności i że wyniki odbiegają wyraźnie od wyników testów w stanie jednoosiowym. Wykorzystanie tych rezerw będzie prowadzić do bardziej ekonomicznych systemów elewacyjnych i zmniejszenia strat ciepła, ponieważ liczba elementów mocujących, a co za tym idzie mostków termicznych zostanie zmniejszona.
EN
Prefabricated reinforced concrete walls with integrated insulation feature a smaller cross-sectional thickness as comparable walls constructed with in-situ concrete. A new tendency in the construction industry is to fasten the two concrete layers with discrete fastenings which run through the insulation layer. The fasteners are made of glass-fibre reinforced polymer (GFRP) bars, which are uniformly distributed over the layer area. In order to set up a concept for the design of such threelayered sandwich walls, it is important to define its load-deflection behaviour, followed by the determination of the internal forces. These are required for the verification of the ultimate and serviceability limit state of the sandwich panels. To investigate the load-deflection behaviour, wall strips with a length of 3600-4000 mm and a width of 800 mm were tested. The sandwich walls consisted of a insulation and two concrete layers. Two types of insulation material were used for the middle layer of the sandwich panels: extruded polystyrene foam (XPS) and expanded polystyrene foam (EPS). Furthermore, the influence of two different thicknesses of the middle layer was investigated, i.e. 60 mm and 140 mm. In order to investigate the load-deflection behaviour, 4-point bending tests were carried out. Due to the higher shear modulus of the extruded polystyrene foam (XPS), it was expected that the behaviour of the specimens with XPS-insulation was stiffer. This paper is aimed to present the results of the test series and to explain the reasons for the different load-deflection behaviours.
PL
Prefabrykowane betonowe ściany ze zintegrowaną izolacją mają mniejszy przekrój a ich właściwości są porównywalne ze ścianami monolitycznymi. Nową tendencją w konstruowaniu takich ścian jest połączenie dwóch warstw betonu za pomocą dyskretnych, ruchomych łączników. Łączniki wykonane są ze wzmocnionych włóknem szklanym polimerowych prętów (GFRP). Opracowanie koncepcji projektowania takich trójwarstwowych ścian wymaga między innymi określenia stanów granicznych użytkowania i nośności. W artykule przedstawiono wyniki badań doświadczalnych takich ścian a w szczególności relacji obciążenie-ugięcie. Badano listwy ścienne o długości 3600-4000 mm i szerokości 800 mm, składające się z dwóch warstw betonu i izolacji. Zastosowano dwa rodzaje materiału izolacyjnego: polistyren (XPS) i styropian (EPS). Ponadto, badano wpływ dwóch różnych grubości warstwy izolacyjnej: 60 mm i 140 mm. W celu określenia relacji obciążenie-ugięcie przeprowadzono badania zginania elementów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.