Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The presented experimental and digital examinations of a two-dimensional turbulent free jet are a first phase of in the study of the Coandă effect and its hysteresis. Additionally, basing on theoretical analyses, selected results for a turbulent jest have been also mentioned, considering theoretical assumptions for the wall layer. As the result, on the basis of experimental, digital, and analytical methods, a review of characteristic jet properties has been prepared, which includes a jet spreading ratio, its cross and longitudinal sections, and turbulence level. The jet spreading radio has been expressed as a non-linear function of the x : b relative length.
PL
W artykule przedstawiono problemy logistyczne prowadzenia badań laboratoryjnych w hydrotechnicznym kanale przepływowym wraz z propozycjami i zastosowanymi rozwiązaniami. Laboratorium hydrotechniczne Instytutu Budownictwa Wydziału Geodezji, Inżynierii Przestrzennej i Budownictwa UWM w Olsztynie wraz z jego wyposażeniem powstało dzięki dofinansowaniu z Programu Operacyjnego „Rozwój Polski Wschodniej 2007 – 2013”. Przedstawiono możliwości badawcze kanału przepływowego, zwrócono uwagę na różnego rodzaju problemy logistyczne związane przede wszystkim z instalacją, pierwszym uruchomieniem, sukcesywną obsługą, innowacyjnymi adaptacjami, ale też rutynową konserwacją nowo zakupionego sprzętu badawczego. Problematyka artykułu wynika z własnych doświadczeń zebranych podczas budowy i prac wykonywanych w laboratorium hydrotechnicznym.
EN
The article presents logistical problems of laboratory studies performed in the flume channel with adopted selected proposals and solutions. The Hydrological laboratory located in the Institute of Civil Engineering of the Faculty of Geodesy, Geospatial and Civil Engineering in Olsztyn, was affirmed thanks to the funds obtained from the Operational Programme „The development of Eastern Poland 2007 – 2013”. The research possibilities provided by the flume channel, various kinds of logistical problems associated with its installation, exploitation, operation, innovative adaptations, but also routine maintenance of newly purchased test equipment were presented. The issues followed from the own experience which was gained during the work performed in the hydrologic laboratory were also presented.
EN
The examinations presented in this article aim at illustrating some possibilities of applying instruments for computational fluid dynamics to assess thermal comfort on the example of a lecture hall in the building of the Institute of Building Engineering at the University of Warmia and Mazury in Olsztyn. The obtained results have been subjected to an analysis according to the guidelines provided in the PN-EN ISO 7730:2006 norm. For the air heating system used in the hall, the distributions of velocity, temperature, as well as the PMV and PDD indices have been subjected to an analysis, with a particular focus on the optimal temperature of the air inflow.
PL
W artykule omówiono problemy związane z zawilgoceniem hal basenowych. Opisano zagrożenia wynikające z niewłaściwie zaprojektowanych i wykonanych stropodachów. Wykazano wpływ wentylacji na stan wilgotnościowy hal basenowych. Zbudowano model numeryczny do oceny rozkładu temperatury oraz kierunków i prędkości powietrza w hali basenowej, który pozytywnie przeszedł weryfikację eksperymentalną.
EN
The article presents the moisture problems of swimming pool halls. There were described the improperly designed and constructed roofs and related moisture risks. The influence of ventilation on the moisture state of pool halls was highlighted. A paper presents the numerical model which was created to assess temperature distribution and the direction and speed of air in the pool hall. The model passed the experimental verification.
PL
Przedstawiono analizę laboratoryjnych danych pomiarowych funkcjonowania rurowego powietrznego gruntowego wymiennika ciepła w lutym 2015 roku. Pomiary wykonano w la-boratorium Zakładu Budownictwa Ogólnego i Fizyki Budowli Uniwersytetu Warmińsko-Mazurskiego w Olsztynie. Dane empiryczne zostały porównane z obliczeniami analitycznymi bazującymi na danych typowego roku meteorologicznego. Wartości temperatury powietrza atmosferycznego w analizowanym okresie były istotnie wyższe niż średnie dane meteorologiczne z okresu trzydziestoletniego co przyczyniło się do uzyskania o 36% mniej ciepła z GPWC w porównaniu z przewidywaniami modelu analitycznego. Zaobserwowano przy tym, że rozkład temperatury powietrza ogrzanego przez grunt w rzeczywistości charakteryzował się większą amplitudą wahań niż przewidywania modelu analitycznego.
EN
The paper presents the analysis of laboratory empirical data on the functioning of a tubular ground-air heat exchanger in February 2015. The measurements were taken in a laboratory of Department of Building Engineering and Building Physics at University of Warmia and Mazury in Olsztyn. The empirical data were compared to analytical calculations based on meteorological data for an average year. The atmospheric air temperature during the analyzed month was significantly higher then the meteorological data averaged for thirty years period. This contributed to real energy gains lower by 36% then the estimates based on the analytical model. It was also observed that the temperature distribution of the air heated by the tubular soil heat exchanger was characterized by a higher amplitude then the predictions of the analytical model.
PL
Przedstawiono raport z badań eksploatacyjnych kolektorów słonecznych wykonanych na stanowisku pomiarowym zlokalizowanym w warunkach naturalnych (polowych), na terenie Uniwersytetu Warmińsko - Mazurskiego w Olsztynie. Pomiary umożliwiają porównywanie uzysków ciepła dwóch odmiennych instalacji kolektorów (płaskich i próżniowych) w identycznych, rzeczywistych warunkach eksploatacyjnych. Stanowisko badawcze składa się z dwóch oddzielnie opomiarowanych, równolegle pracujących instalacji kolektorów podłączonych do jednego zbiornika buforowego. Rejestracja danych pomiarowych odbywa się przez sterownik, który przesyła je do komputera w celu archiwizacji i przetwarzania. Przedstawiono porównawczą analizę wyników pomiarowych dla badanych instalacji pracujących w okresie zimowym.
EN
The presents a report of exploitative research of solar collectors conducted at a test bench located in natural conditions. The research was conducted at Warmia and Mazury University campus in Olsztyn. Measurements allow for comparison of heat gains from two different solar collectors installations (flat and vacuum) in identical, natural conditions. The test bench consisted of two installations with separate measurements, working simultaneously in identical weather conditions. The recording of the empirical data was done through a controller directing it to a computer for storage and processing. The paper presents measurement data for the winter period.
EN
The aim of this paper is to give the insight into the energy and exergy analysis and the usefulness of the exergy balance next to the energy balance for the evaluation of the different kind of buildings. In our case we applied this method to the traditional and low-energy (passive) showing the differences in heating systems used for these buildings. In traditional house the condensing boiler and water heating radiator were used while in the passive the heat pump and air heating were used. The exergy analysis showed that the exergy destruction for the low-energy house is much lower than for the conventional one.
PL
Celem artykułu oprócz bilansu energii, jest bilans egzergii oraz wykazanie jej przydatności do oceny różnych rodzajów budynków. Zastosowano tę metodę do budynku tradycyjnego i niskoenergetycznego (pasywnego) i wskazano na różnice w zastosowaniu różnych systemów ogrzewania w budynkach. W budynku tradycyjnym zastosowano kocioł kondensacyjny i grzejniki radiacyjne, w budynku pasywnym pompę ciepła i ogrzewanie powietrzne. Po analizie egzergii wykazano, że w budynku niskoenergetycznym destrukcja egzergii jest znacznie mniejsza niż w budynku konwencjonalnym.
8
Content available remote Analiza energii i egzergii domu niskoenergetycznego i pasywnego
PL
W artykule porównano wyniki analizy energii i egzergii wykonane dla jednorodzinnego domu niskoenergetycznego i domu pasywnego o zbliżonych projektach. Analiza egzergii umożliwia ocenę sprawności energetycznej różnych obiegów cieplnych oraz określenie, gdzie w całym procesie przepływu energii, dochodzi do największych jej strat.
EN
The paper presents the comparison of energy and exergy analysis conducted for low energy and passive houses of similar design. Exergy analysis enables the efficiency estimation of different heating systems. It also indicates where in the whole process of energy flow, the energy losses are the biggest.
EN
Appropriate air distribution in a room is necessary for thermal comfort. By using Computational Fluid Dynamics (CFD) it is possible to compare optional ways of air supply and distribution at the stage of the ventilation design concept. Using these simulations the ventilation system designer can choose the best method of air supply in the room diminishing the risk of an incorrect solution.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.