Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The analysis of electromyographic signals can be very time consuming. In designing a program for EMG signal analysis, there are two competing factors: the accuracy of the final result and its speed. In scientific work, accuracy is the most important factor. All of the existing decomposition programs used in neurophysiology require a final phase of manual corrections, if reliable results are to be obtained. This phase is considerably longer than the phase of automatic recognition. The solutions presented below, used in our new MUR program, allow for the accurate decomposition of complex EMG signals in a reasonable amount of time. The decomposition is performed interactively with optimal time division between automatic and manual tasks. All of this is achieved through a simple method of automatic recognition with the use of the modified coefficient of determination and the method of multiple subtractions of potentials.
EN
The aim of this paper is to analyse the influence on a standing thermal manikin of various factors such as thermal environment parameters (temperature, humidity, velocity/direction of air flow), how heating power is transferred to the manikin, and the time required to reach thermal balance during tests with thermal clothing insulation. Three sets of clothing, designed for protecting before cold, intended for use at very low temperatures (0, -10 and -25 °C) were tested in a climatic chamber on a standing thermal manikin. The results of the tests yielded the following results: 1) methods to control the transfer of heating power to the manikin have a negligible influence on the determined value of clothing thermal insulation, 2) air velocity decreases the tested thermal insulation by 7%, whereas an increase in temperature increases the thermal insulation, 3) temperature in a climatic chamber should be determined in accordance with the anticipated clothing insulation of the clothing ensemble being tested. The tests showed that in order to obtain reliable and accurate results, it is necessary to maintain an appropriate air velocity in the climatic chamber, of around 0.3 to 0.5 m/s, and an appropriate difference in temperatures between the manikin’s surface and the environment at a minimum of 12 °C.
PL
Celem pracy była analiza wpływu na termiczny manekin takich czynników, jak: parametry otoczenia (temperatura, wilgotność, szybkość/kierunek strumienia powietrza), sposób przekazywania mocy grzejnej do manekina oraz czas wymagany do osiągnięcia równowagi termicznej. Na manekinie umieszczonym w komorze klimatycznej testowano trzy zestawy odzieży zaprojektowanej do ochrony przed zimnem i przeznaczonej do używania w bardzo niskich temperaturach (0, -10 i -25 °C). Wyniki pomiarów przedstawiały się następująco: 1) metody służące do kontroli przekazywania mocy grzewczej do manekina mają nieznaczny wpływ na wyznaczoną wartość izolacyjności cieplnej odzieży, 2) prędkość powietrza obniża badaną izolacyjność termiczną o 7%, podczas gdy wzrost temperatury powoduje również wzrost izolacyjności cieplnej, 3) temperatura w komorze klimatycznej powinna być określona zgodnie z przewidywaną izolacyjnością cieplną badanej odzieży. Testy pokazują, że w celu uzyskania rzetelnych i dokładnych wyników, niezbędne jest zachowanie odpowiedniej prędkości powietrza w komorze klimatycznej, na poziomie około 0,3 – 0,5 m/s i właściwej różnicy temperatur pomiędzy powierzchnią manekina a otoczeniem, minimalnie 12 °C.
PL
Środowisko termiczne, w jakim przebywa człowiek wykonujący pracę w warunkach obciążeń termicznych może mieć ujemny wpływ na jego zdrowie. Dotyczy to zarówno środowisk nadmiernie gorących jak i nadmiernie zimnych. Ciało ludzkie jest zaopatrzone w naturalne mechanizmy termoregulacji. Gdy zostaną przekroczone granice tolerancji organizmu na oddziaływanie tych czynników, konieczne staje się zapobieganie wystąpieniu negatywnych następstw. Aby chronić człowieka w środowisku pracy należy zapewnić mu odpowiednie środki ochrony. Zagrożenia tego typu można oceniać poprzez pomiar parametrów charakteryzujących dane środowisko i wyznaczenie odpowiednich wskaźników umożliwiających określenie stopnia zagrożenia ze strony stresu termicznego.
EN
The thermal environment in the workplace may have a negative influence on human health. This refers both to too hot and too cold environments. The human body is equipped with natural thermoregulation mechanisms. When tolerance limits on the influence of this exposure is exceeded, it becomes necessary to prevent negative consequences. To protect humans in the working environment it is necessary to provide them with suitable protection measures in the form of appropriate types of clothing and organization of their working time. Climatic and demographic changes favour the appearance of thermal loads. This type of risk can be assessed through measurements of parameters characterizing a given environment and calculation or assessment of appropriate rates. To this end the Central Institute for Labour Protection - National Research Institute is in the process of setting up a National Centre on Research Dealing with Limiting Risks of Employees Resulting from Hot or Cold Environments. Its activity will target minimization or elimination of this type of hazard in the workplace.
4
Content available remote Wpływ napełniaczy dwufazowych na właściwości fizyczne wulkanizatów
PL
Wykonano trzy serie mieszanek gumowych zawierających: kauczuk naturalny, napełniacze dwufazowe (sadza z dodatkiem krzemionki) CRX 4210, BP 460 oraz sadzę N 220. Mieszanki różniły się tylko rodzajem i ilością napełniaczy. Zawartość napełniacza w serii zmieniano w zakresie od 0 do 80 phr. W celu porównania wpływu sadzy na właściwości fizyczne wulkanizatów wykonano serię mieszanek z sadzą N 220 oraz mieszankę bez napełniacza. Porównano właściwości fizyczne odpowiednich wulkanizatów. Stwierdzono, że wpływ napełniaczy na właściwości fizyczne wulkanizatów zależy zarówno od rodzaju i warunków badania, jak i od zawartości napełniacza w mieszance. Badania odporności wulkanizatów na ścieranie wykazały korzystny wpływ napełniacza BP 460, zaś wulkanizaty zawierające napełniacz CRX 4210 wykazywały najsłabszą odporność na ścieranie. W badaniach dynamicznych próbki zawierające napełniacz CRX 4210 wykazywały lepsze właściwości tłumiące w szerszym przedziale odkształceń względnych niż te, które zawierały napełniacz BP460. Przedstawiono zależność efektu Payne'a (spadku modułu przy wzroście amplitudy odkształcenia) od powierzchni właściwej i "struktury" napełniaczy.
EN
Three series of natural rubber based compounds has been made. In the series of compounds the type and amount of fillers have been changed. The filler content in each blend of series was varied from 0 to 80 phr. In each series appropriate filler was given. In order to compare physical properties of vulcanizates, the series of compounds filled with N 220 carbon black was made. It was proved, that the influence of the fillers on the properties of vulcanizates depends on the type and a content of fillers. The investigation of the abrasion resistance of vulcanizates shows that the filler BP 460 is the best, and the filler CRX 4210 gives the change for the worse. In dynamical properties of vulcanizates the vulcanizates containing filler CRX 4210 have better damping properties in wider range of strain amplitude than that filled with BP 460. The influence of surface area and "structure" of carbon black on the Payne effect (the modulus decrease due to the amplitude increase) have been presented.
PL
Przedstawiono wybrane problemy numerycznej symulacji pól temperatury, wykonywanej przez Zakład Fizyki Cieplnej ITB. Potrzeba wykonywania symulacji komputerowej wystepuje przy obliczaniu oporu cieplnego drążonych kształtek i pustaków oraz ram okiennych, współczynnika przenikania ciepła złożonych przegród zewnętrznych (z mostkami cieplnymi), przy ocenie kondensacji pary wodnej na powierzchni węzłów konstrukcji. Specyfika rozwiązywanych zadań przewodzenia ciepła, obejmująca duże zróżnicowanie wartości współczynnika przewodzenia ciepła i grubości warstw materiałów, wymaga stosowania programów z automatyczną generacja siatek. Jednym z używanych w Zakładzie Fizyki Cieplnej narzędzi komputerowych jest pakiet programów PHYSIBEL. W skład pakietu wchodzą między innymi programy: KOBRU86, BISCO, TRISCO. KOBRU86 jest przeznaczony do obliczania ustalonych stanów przepływu ciepła w dwuwymiarowych obiektach, których kształt można złożyć ze skończonej liczby prostokątów. BISCO służy do obliczania ustalonych stanów przepływu ciepła w obiektach dwuwymiarowych o dowolnym kształcie (mogą to być obiekty zawierające elementy krzywoliniowe). TRISCO pozwala badać stacjonarny przepływ ciepła w obiektach trójwymiarowych, które mogą być opisane za pomocą prostopadłościennych bloków. W atykule przedstawiono przykladowe obliczenia pól temperatury.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.