Content available remote Electroconductive polymers in (bio)chemical sensors
EN
In this paper, research concerning application of electroconducting polymers in biosensors is discussed. Selection of the electropolymers has been limited to those which monomers are water-soluble, such as: polypyrrole and polyaniline. In general, experiments concerning EP utilization in dehydrogenase based biosensors were divided in four stages: (I) incorporation of mediators as dopants of the EP's layer, (2) immobilization of cofactors e.g. NAD+/NADH, (3) immobilization of enzymes and (4) immobilization of all components: mediator, cofactor and enzyme. As a dopant of the PPy water-soluble electroactive compound ferrocyanide was used. Another EP, namely polyaniline was also tested as an electrode material for NADH detection based on its electrochemical oxidation. In the case of simultaneous immobilization of mediator, NAD, and ADH in the PPy layer, as a result of the ethanol oxidation, the oxidation peaks of the mediator become smaller whereas the oxidation peaks of PPy increase. In the analyzed EtOH concentration range (O - 2 mM), slope of calibration curve for the PPy oxidation peak was around 20 \miA/mM. In the case of PAn deposition on the platinum electrode, decrease of the oxidation potential for NADH by 0.4 V was observed.
PL
W artykule przedstawiono modyfikację amperometrycznych czujników do oznaczania NADH. Czujniki z elektrodami platynowymi modyfikowano za pomocą polianiliny (PAn), dobierając parametry elektropolimeryzacji aniliny, w tym: potencjał i czas polimeryzacji oraz stężenie monomeru. Największą czułość na NADH uzyskano w przypadku osadzania PAn z roztworu 0,3 M An metodą chronoamperometryczną przy potencjale 0,75 V w czasie 3 min. Zastosowanie polianiliny jako materiału elektrody, poza zwiększeniem czułości czujnika, powoduje obniżenie potencjału utleniania NADH.
EN
In this paper, modifications of amperometric sensors for the determination of NADH are described. The sensors with platinum electrodes were modified with polyaniline (PAn) deposited in different aniline electropolymerization processes tuned by potential and time of electropolymerization as well as monomer concentration. Based on calculated sensitivity to NADH, the best conditions of electropolymerization were chosen: 0.3 M An, 0.75 V and 3 min. Application of polyaniline as an electrode material causes: reduction of oxidation potential of NADH by 400 mV, higher current values and increase in sensitivity of the sensor for NADH.
PL
W artykule omówiono różne rodzaje chromizmu oraz różne materiały elektrochromowych, a także opisano budowę klasycznego urządzenia elektrochromowego. Przedstawiono przegląd typowych polimerów elektrochromowych, ze szczególnym uwzględnieniem polianiliny, która wykazuje polielektrochrornizm oraz halochromizm.
EN
This paper discusses different types of chromism and various electrochromic materials, as well as construction of classical electrochromic devices. A review of commonly used electrochromic polymers is presented. A special concern is related to polyaniline, which exhibits both polyelectrochromism and halochromism.
EN
In this paper, the study on electrochemical polymerization of pyrrole with an electron transfer mediator in the electrocatalytic processes is described. Code position of ferricyanide and polypyrrole, increases conductivity of the doped polymer. The best method for the electropolymerization was cyclic voltammetry, which al lows in situ estimation of quality and thickness of the formed layers. The oxidation/reduction peaks for the mediator and pyrrole are strongly dependent on chloride ions presence in the monomer solution. The proposed redox system, Ppy/Fe(CN)6 3-, is efficient and can be used as a platform for advanced biochemical reactions in biosensors research.
PL
W artykule przedstawiono wyniki badań dotyczące elektrochemicznej polimeryzacji pirolu połączonej z immobilizacja dinukleotydu nikotynoamidoadeninowego. Porównano dwie metody immobilizacji koenzymu (potencjostatyczną i potencjodynamiczną) w formie utlenionej (NAD) oraz zredukowanej (NADH). Dodatek NADH do roztworu monomeru w znacznie większym stopniu niż NAD wpływa na przebieg polimeryzacji pirolu oraz przewodność uzyskiwanej warstwy.
EN
The study on electrochemical polymerization of pyrrole with simultaneous immobilization of the nicotinamide adenine dinucleotide is described. Two methods of immobilization of the coenzyme (potentiostatic and potentiodynamic) in its oxidized (NAD) or reduced (NADH) form, are compared. Addition of the NADH to the monomer solution influences the polymerization process and conductivity of the obtained layer in larger extend than NAD.
PL
Zaprezentowano przykłady oraz omówiono zastosowanie bioczujników enzymatycznych opartych na dehydrogenazach, wykorzystujących koenzym NAD+. Opisano różne technologie wytwarzania bioczujników oraz różne metody detekcji. Porównano dwa sposoby regeneracji koenzymu za pomocą dodatkowego systemu enzymatycznego przy wykorzystaniu diaforazy oraz mediatora przenoszenia elektronów. Przedstawiono jedną z metod ulepszania bioczujników amperometrycznych, polegającą na zastosowaniu elektroprzewodzącego polipirolu domieszkowanego elektroaktywnym mediatorem (żelazocyjanek).
EN
This paper presents examples and application of enzymatic biosensors based on NAD+ -dependent dehydrogenases. Different technologies of biosensors fabrication and different methods of detection are described. Two methods of the coenzyme regeneration with additional enzymatic system using diaphorase and with the electron transfer mediator are compared. A method of improving of amperometric biosensors by applying electroconducting polypyrrole doped with electroactive mediator (ferrocyanide) is presented.