Biodiesel has become more attractive material for its properties such as biodegradability, renewability and very low toxicity of its combustion products. A higher quality of this fuel is essential in its potential commercialization. Analytical methods used in biodiesel analysis are constantly refined. The most popular analytical techniques include chromatography and molecular spectroscopy. The ATR-FTIR spectroscopy is one of the most important methods of spectroscopy. This paper presents the results of studies on selected oils of natural origin using ATR-FTIR infrared absorption spectroscopy. Three types of oils from pumpkin seeds and winter rapeseed were analysed. The main fatty acids were also determined in all the samples.
PL
Biodiesel staje się coraz bardziej atrakcyjnym materiałem ze względu na swoje właściwości takie jak: biodegradowalność, odnawialność oraz bardzo niską toksyczność produktów powstających z jego spalania. Jakość tego paliwa ma również docelowo zasadnicze znaczenie w jego potencjalnej komercjalizacji. Metody analityczne używane w badaniach biodiesla są cały czas udoskonalane. Do najpopularniejszych technik analitycznych zaliczyć należy chromatografię oraz metody spektroskopii molekularnej, a wśród nich spektroskopię w podczerwieni ATR-FTIR. W prezentowanym artykule przedstawiono wyniki badań wykonanych za pomocą spektroskopii absorpcyjnej w podczerwieni ATR-FTIR wybranych do badań olejów pochodzenia naturalnego, tj. z nasion dyni oraz rzepaku ozimego. We wszystkich próbkach oznaczono także zawartość głównych kwasów tłuszczowych.
This paper presents the design and measurements of low-noise multichannel front-end electronics for recording extra-cellular neuronal signals using microelectrode arrays. The integrated circuit contains 64 readout channels and is fabricated in CMOS 180 nm technology. A single readout channel is built of an AC coupling circuit at the input, a low-noise preamplifier, a band-pass filter and a second amplifier. In order to reduce the number of output lines, the 64 analog signals from readout channels are multiplexed to a single output by an analog multiplexer. The chip is optimized for low noise and good matching performance and has the possibility of passband tuning. The low cut-off frequency can be tuned in the 1 Hz - 60 Hz range while the high cut-off frequency can be tuned in the 3.5 kHz - 15 kHz range. For the nominal gain setting at 44 dB and power dissipation per single channel of 220 žW, the equivalent input noise is in the range from 6 žV - 11 žV rms depending on the band-pass filter settings. The chip has good uniformity concerning the spread of its electrical parameters from channel to channel. The spread of the gain calculated as standard deviation to mean value is about 4.4% and the spread of the low cut-off frequency set at 1.6 Hz is only 0.07 Hz. The chip occupies 5×2.3 mm⊃2 of silicon area. To our knowledge, our solution is the first reported multichannel recording system which allows to set in each recording channel the low cut-off frequency within a single Hz with a small spread of this parameter from channel to channel. The first recordings of action potentials from the thalamus of the rat under urethane anesthesia are presented.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A 64–channel ASIC called SXDR64 has been developed. The ASIC is aimed to work with DC coupled CdTe and GaAs detectors. Each channel of ASIC consists of charge sensitive amplifier, pole-zero cancellation circuit, 4th order shaper with programmable gain and peaking time from 115 ns to 380 ns, base-line restorer, two independent discriminators and two 20-bit counters. Simulated equivalent noise charge of the frontend electronics for 3 pF detector capacitance, detector leakage current of 500 pA and peaking time Tp = 380 ns is 123 electrons rms.
PL
SXDR64 jest 64-kanałowym układem scalonym przeznaczonym do odczytu sygnałów z detektorów CdTe oraz GaAs promieniowania X. Każdy kanał w układzie składa się ze wzmacniacza ładunkowego, układu kompensacji biegun-zero, układu kształtującego 4 stopnia, układu przywracania poziomu stałego, dwóch niezależnych dyskryminatorów oraz dwóch 20-bitowych liczników. Szumy oszacowane z symulacji wynoszą 123 el. rms, przy pojemności detektora 3p, prądzie upływu 0.5 nA.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A study on the buffer layer dependence of the film texture, surface roughness, and magnetization reversal process in Co/Pt multilayers prepared by dc magnetron sputtering is presented. Oxidized Si(100) wafer was covered with four different buffers: (A) 10 nm Cu, (B) 5 nm Ta/10 nm Cu, (C) 5 nm Ta/10 nm Cu/5 nm Ta, and (D) 5 nm Ta/10 nm Cu/5 nm Ta/10 nm Cu. The growth of [2 nm Pt/0.5 nm Co]×5/2 nm Pt on top of these buffer layers results in a large variation in the fcc (111) Co/Pt texture and surface morphology. All films have the perpendicular magnetic anisotropy but magnetization reversal process, studied by the magnetooptic Kerr effect (MOKE) and magnetic force spectroscopy (MFM), strongly depends on the buffer used. Observation of magnetic domains evolution under a MOKE microscope allows one to calculate from magnetization relaxation curves average dispersion of energy barriers of the thermal activated magnetization switching process. The application of MFM in external magnetic field allows one to follow the dynamics of direct and indirect magnetization switching procesess up to submicrometer scale.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper describes the performance of multichannel ASIC (called FX) which has been connected to Schottky CdTe detector by DC coupling. Because of DC coupling, leakage current of the detector flows into readout electronics and changes its performance. The I-V characteristic of CdTe Schottky detector with guard ring have been measured and we have performed both simulation and experimental verification of FX IC behavior vs. detector leakage current. Due to the low values of this detector leakage current (140 pA for bias voltage of 700 V) performance of FX IC is slightly influenced. Measurements performed with low values of detector's leakage current (below 1 nA), show that the gain of readout channel stays constant with changes of leakage current, while the offset voltage at the discrimonator input changes linearly of about 4.5 mV per 100 pA of the detector leakage current. Limitations of DC coupling method are shown based on measurements with Schottky CdTe detector without guard ring, which produces higer leakage current.
Celem podjętych badań było określenie wpływu różnych poziomów nawożenia na jakość technologiczną nasion wybranych odmian rzepaku ozimego. Materiał do badań stanowiły próbki nasion 6 odmian rzepaku ozimego pochodzące z doświadczeń odmianowo - nawozowych w Stacji Doświadczalnej Oceny Odmian w Głębokim w latach 2002-2004. Doświadczenie zostało założone w oparciu o metodę split- block. Wartość technologiczną nasion oceniano na podstawie: plonu, zawartości białka i tłuszczu. W badaniach zastosowano metody analiz chemicznych i spektrometrii bliskiej podczerwieni polegające na określeniu zawartości tłuszczu surowego i białka ogółem w nasionach. Przeprowadzone badania wykazały, że na jakość technologiczną nasion rzepaku wpływają zarówno sezony wegetacyjne, jak i poziomy zastosowanego nawożenia.
EN
The purpose of the study was to determine different fertilizing levels on technological quality of selected varieties of winter rapeseeds. The test material were samples of seeds of 6 varieties of winter rapeseed coming from experiments on varieties and fertilizers in the Variety Assessment Experimental Plant in Głębokie in the years 2002 - 2004. The experiment was based on split-block method. The technological value of the seeds was assessed based on: yield, content of proteins and fat. In the study, the methods of chemical analyses and near infrared spectrometry were used, consisting in establishing the content of raw fat and general protein in the seeds. The test showed that the technological quality of the rapeseeds is influenced by both vegetation seasons and fertilization levels.
Celem przeprowadzonych badań było dokonanie oceny jakości suszonego surowca dostarczonego do zakładów tłuszczowych. Badaniami objęto 108 próby nasion rzepaku w trzech latach badań: 2001, 2002, 2003. Na ich podstawie stwierdzono, że 54% stosowanych suszarń ma więcej niż 5 lat, a 31% ma powyżej 20 lat. Ponad połowę badanych suszarń użyło temperatury powyżej 70°C, szczególnie w lata o niekorzystnym przebiegu pogody. Wartość technologiczna ocenianego surowca w większości wykazywała bardzo dobre i dobre właściwości pod względem badanych cech. Tylko nieznaczna ilość materiału charakteryzowała się gorszymi właściwościami i to szczególnie pod względem właściwości oksydacyjnych (wysoka liczba nadtlenkowa). Przyczyną mogła być znaczna ilość nasion uszkodzonych mechanicznie.
EN
The aim of this research was to evaluate the quality of dried raw material delivered to vegetable fat industry. There were 108 samples of rapeseed delivered for the review. Three years of harvest were investigated 2001, 2002, 2003. It appears from the conducted research that 54% of all the used drying facilities are more than 5 years old, while 31% are above 20 years. In more than half of the facilities the applied drying temperature exceeded 70°C, in particular in years with bad weather conditions. The technological value of all the analyzed raw material was in major part of good and very good quality of properties. Only small quantity was of worse quality in particular in respect of oxidative stability (high peroxide value). A cause of this could be the fact that vast part of the seeds was mechanically damaged.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.