Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Zero concentrate flow discharge membrane techniques for natural water treatment
EN
The main problem of modern RO and NF membrane techniques is the existence of concentrate flow that creates a problem of its utilization. Large amounts of RO/NF effluents are mainly attributed to fouling and scaling protection. Research of scaling and fouling mechanisms showed that these processes depend not only on hydraulic and hydrodynamic factors, but on membrane channel configuration as well. The novel concept of spiral wound module with the modified membrane channel (called “open channel”) is developed, fieldtested and introduced into practice. Fouling control is achieved due to the elimination of spacer and the implementation of an optimum hydraulic mode. Modification of channel provides the possibility to reach high recoveries and high supersaturation values due to strong stability of calcium carbonate solutions. The main principles of high recoveries and zero discharge are ensured by concentration of brine through re-circulation by 50-100 times by volume. Coagulated suspended matter after membrane flushes is collected, sedimented and finally dewatered. In case of hard water treatment the excessive calcium carbonate could be concentrated in membrane modules and subsequently precipitated, sedimented and dewatered. Several examples of water treatment flow diagrams are presented to demonstrate the principles of zero concentrate flow discharge.
PL
Podstawowym problemem współczesnych instalacji odwróconej osmozy i nanofiltracji jest powstawanie dużych ilości trudnego do zagospodarowania koncentratu. Problem ten nasila się w przypadku wystąpienia zjawisk fouling’u i scaling’u. Badania mechanizmu procesów fouling’u i scaling’u wykazały, że obok warunków hydraulicznych i hydrodynamicznych ma na nie wpływ konfiguracja kanałów ukierunkowujących przepływ przez membranę. Opracowano nową koncepcję modułu spiralnego z ukierunkowanym przepływem (nazywaną “open channel”) dzięki zastosowaniu odpowiednich przekładek w konstrukcji modułu membrany. Dobranie optymalnych parametrów hydraulicznych i eliminacja stref martwych pomogło w kontroli zjawiska foulingu i scalingu. Zastosowane rozwiązanie budowy modułów membranowych zapewnia możliwość uzyskania recurkulatu o dużym stężeniu dzięki silnej stabilności roztworu węglanu wapnia. Wysoki odzysk zapewnia 50-100-krotna recyrkulacja stężonej solanki. Zawiesina wypłukiwana z membran po koagulacji jest poddawana sedymentacji i odwadnianiu. Zaprezentowano kilka przykładowych schematów uzdatniania wody wykorzystujących przyjęte rozwiązania.
EN
Survey shows that high operational costs of membrane facilities and large amounts of effluents are mainly attributed to fouling and scaling. Research of scaling and fouling mechanisms showed that these processes depend not only on hydraulic and hydrodynamic factors, but on membrane type, material and channel configuration as well. Operational parameters of different membrane configurations show that spiral wound modules demonstrate best hydraulic and hydrodynamic characteristics combined with lowest price. Main ways to develop new fouling-free techniques are outlined that require modified "open-chan-nel" spiral wound membranes. Elimination of "deadlocks" as a main cause of scaling and fouling provide new technological approach to develop water treatment techniques without pretreatment facilities and chemicals. Modification of channel provides possibility to reach high recoveries and high supersaturation values due to strong stability of calcium carbonate solutions. Membrane transport is not only purification instrument it is also a reactor to coagulate, concentrate and precipitate water constituents on membrane surface. Several examples of water treatment flow diagrams are presented to demonstrate principles of zero concentrate flow discharge. Coagulated suspended matter after membrane flushes is collected, sedimented and finally dewatered. The dewatered sludge contains averagely 0,8 per cent of initial water. Due to the use of an "open-channel" modules membrane brine flow could be concentrated by many times without a fear of scaling and added to the sludge. Thus the excessive salts and impurities could be withdrawn from water systems together with partially dewatered sludge. Similarly excessive calcium carbonate could be also concentrated in membrane modules and subsequently precipitated, sedimented and dewatered. Solution of fouling problems thus provides a new approach to save operational costs and to increase ecological efficiency of membrane water treatment tools.
PL
Badania wykazują, iż wysokie koszty eksploatacji urządzeń z zastosowaniem membran i duże ilości odcieków są przypisywane zanieczyszczeniom i odkładaniu się kamienia. Procesy te zależą nie tylko od czynników hydraulicznych i hydrodynamicznych, ale także od rodzaju membran i materiałów użytych do ich budowy. Parametry pracy różnych membran wykazały najlepsze właściwości modułów spiralnych przy najniższej cenie. Przepływ przez membrany nie ogranicza się jedynie do oczyszczania, jest to także reaktor do koagulacji, zatężania i strącania. Zawiesina po procesie koagulacji z procesu czyszczenia membran jest poddana sedymentacji i odwadnianiu. Osad z odwadniania zawiera około 8% wody. Zastosowanie modułów o "otwartych kanałach" powoduje zmniejszenie zagrożenia zanieczyszczenia i odkładania się kamienia. Rozwiązanie problemu zmniejszenia zanieczyszczenia membran pozwoli zmniejszyć koszty pracy instalacji i spowoduje wyższy poziom ekologicznej efektywności narzędzi wykorzystujących technikę membranową.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.