This paper presents the possibility of using a fuzzy controller to correct metrological properties of an electric traction energy meter. So far, no algorithms based on fuzzy logic to determine the desired conversion value of the current channel of the electricity meter have been applied. Currently, for the mentioned channel, conventional methods of gain determination are used, based on a sequential algorithm that controls operation of the programmable gain amplifier. The proposed corrector is designed for smart and continuous modification of the conversion factor of the low-voltage input part of the current channel in the electric energy meter. The authors have performed an accurate analysis of the current function in the main circuit of an electric locomotive by creating a model of a traction inverter subject to asynchronous motor load. An essential concept is this paper is to present the possibility of having a multi-input fuzzy controller split into two-input controllers connected in parallel and cascade. By performing a computer simulation of systems used for correcting metrological properties of electric traction energy meters, it has been proven that the applied fuzzy systems, based on an expert’s knowledge of digitally controlled PGA (Programmable Gain Amplifier) type operational amplifiers, are advantageous.
This paper presents the theory about generating the braking curve and the analysis of the influence of the braking controller parameters on the generation of the braking curve of the train. In this paper, computed examples of braking quality developed using generic quality factor are shown, and on the basis of the calculations, weight components of the factor and an additional criterion for assessing the quality of braking were proposed. It has been demonstrated that the developed algorithms can be used to verify the effectiveness of the braking controller and the adjustment of the terms, and the change of these algorithms affects the shape of the generated braking curve of the train. It has been shown that the analysis of a failure of the propulsion car revealed the existence of a safe braking area. The performed statistical analysis confirmed the normal distribution of the scatter of braking results, for which the regression model fitted.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono mankamenty i problemy metrologiczne w pomiarach prądu i napięcia w układach pomiarowych składających się z kaskadowego połączenia wzmacniacza operacyjnego, filtru dolnoprzepustowego, przetwornika analogowo cyfrowego oraz mikroprocesorowego systemu zbierania danych. Autorzy pracy podali także zalety sterowania rozmytego w układach cyfrowych oraz możliwość wykorzystania tego inteligentnego sterownika w układzie automatycznej korekcji wzmocnienia pozwalającego na modyfikacje stałej przetwarzania analogowego toru w sposób ciągły. W niniejszej pracy także opisano także przyczynę powstania błędu powierzchniowego sterownika Mamdani’ego oraz jego niwelację i wpływ na właściwości metrologiczne układu korekcji.
EN
The paper presents shortcomings and metrological problems in the measurement of current and voltage in measurement systems consisting of a cascade connection of an operational amplifier, a low-pass filter, an analogue-digital converter and a microprocessor data acquisition system. The authors also gave the advantages of fuzzy control in digital circuits and the possibility of using this intelligent controller in the automatic gain correction system allowing modification of the gain factor analog path in a continuous manner. This paper also describes the cause of the surface error of the Mamdani controller and its leveling and influence on the metrological properties of the correction system.
W artykule opisano mikroprocesorowy system pomiarowy przeznaczony do zdalnego pomiaru temperatury. System składa się nadajnika mierzącego temperaturę oraz odbiornika wizualizującego wartość temperatury na wyświetlaczu LCD. Przesyłanie danych odbywa się za pośrednictwem transmisji radiowej na częstotliwości 433 MHz. Pierwsza część artykułu zawiera krótki wstęp poruszający kwestię komunikacji bezprzewodowej. Kolejne punkty zawierają opis zastosowanych elementów, sposób wykonania układu pomiarowego, oraz zasadę jego działania. Na zakończenie przedstawiona została weryfikacja działania wykonanego układu, zbadano zasięg w zależności od typu anteny oraz napięcia zasilającego układ pomiarowy.
EN
The aim of this article was the development and implementation of microprocessor measurement system designed to measure the temperature. The system includes a transmitter for measuring temperature and a receiver that displays the temperature value on the LCD display. Data transmission between the transmitter and the receiver uses radio waves at a frequency of 433 MHz. The first part of the article contains a brief introduction to wireless communication. Next chapter contains description created measuring system, used components, manufacturing method and the principle of action. In experimental part tested operation of the created system and range depending on the type of antenna and the supply voltage.
W artykule przedstawiono model falownika napięciowego typu DC/AC wykorzystywany w zmodernizowanych elektrycznych zespołach trakcyjnych (EZT). W przekształtniku tym wykorzystano metodę sterowania typu SVPWM (ang. Space Vector Pulse Width Modulation), która pozwala w sposób dokładny odwzorować na jego zaciskach wyjściowych przebiegi napięcia sinusoidalnie zmiennego. Obwód tego typu pracujący w sieci trakcyjnej generuje tętnienia wartości wejściowego prądu o częstotliwości sześciokrotnie wyższej niż częstotliwość jego napięcia wyjściowego. Na wejściu DC obwodu pośredniczącego falownika w elektrycznej trakcji szynowej monitoruje się wartość prądu obciążenia sieci jezdnej m.in. do wyznaczenia pobieranej energii elektrycznej pobranej przez zespół trakcyjny.
EN
In the paper presented the model of the voltage inverter type DC/AC used in modernized electrical traction. In this inverter, the SVPWM (Space Vector Pulse Width Modulation) control method was used which allow to the accurately imitate the voltage sinusoidal variable waveforms on its output connectors. The circuit of this type working in overhead contact line generates pulsations of input-current at a frequency six times higher than the frequency of its output voltage. At the DC input of the inverter circuit in the electric traction rail, the load current of the mains network is monitored. to determine the electricity consumed by the traction unit.
Autorzy przedstawili w sposób syntetyczny mankamenty wejściowych wzmacniaczy programowalnych stosowanych w układach wejściowych przetworników pomiarowych oraz zaprezentowali sposób działania scalonych układów o wzmocnieniu regulowanym napięciowo. W artykule przestawiono także możliwości wykorzystania ww. wzmacniaczy w układzie automatycznej korekcji wzmocnienia toru prądowego przetwornika mocy czynnej lub licznika energii elektrycznej.
EN
The authors of this paper presented in synthetic way the metrological drawbacks of input programmable operational amplifier used in the input channel of integrated transducer also shown the principle of operation integrated operational amplifier with programmable gain. In this paper authors also presented the capability of using mentioned earlier in paper operational amplifier in automatic gain correction circuit in the current channel of active power transducer or watt-hours meter.
W artykule omówiona została teoria i metoda generacji krzywej hamowania. Zaprezentowano wyniki badań dokładności i jakości hamowania oraz pokazano wpływ zmiany parametrów regulatora na modelowanie krzywej hamowania, a wyniki zostały zinterpretowane. Omówiono ogólny wskaźnik jakości hamowania oraz pokazano obliczenia jakości procesu hamowania docelowego uwzględniające realizację wzorcowej krzywej hamowania dla przykładowego procesu hamowania. Obliczenia krzywej hamowania zostały zrealizowane w oparciu o autorskie programowe odwzorowanie systemu realizującego także funkcję hamowania docelowego. Przedstawione zostały także wstępnie dobrane wagi poszczególnych składników wskaźnika jakości oraz rezultaty obliczeń jakości hamowania docelowego pociągu metra. Przedyskutowano wpływ awarii taboru (zanik napięcia) na proces bezpiecznego automatycznego zatrzymania pociągu.
EN
In the paper a basic function of an Automatic Train Operation (ATO) called target braking has been discussed. The most important assumptions of this function have been discussed in detail. The author's simulation model, which was developed to study the impact of the propulsion systems on the precision and quality of train braking also allows to perform in dynamic conditions the target braking process and it provides the ability to calculate braking accuracy. There was shown that the simulator allows to calculate the quality factor, which makes possible the assessment of generated braking curve and the results was discussed.
W artykule zaprezentowano możliwość wykorzystania sterownika rozmytego do korekcji właściwości metrologicznych trakcyjnego licznika energii elektrycznej. Zaprojektowany korektor umożliwia w sposób inteligentny modyfikację stałej przetwarzania wejściowej niskonapięciowej części toru prądowego licznika energii elektrycznej.
EN
The paper was presented the possibility of using the fuzzy logic controller to correcting the metrological characteristics of the traction electricity watt-hours meter. Designed signal gain corrector allow to intelligently modification of the gain of in the low voltage input of the current path electricity watt-hours meter.
W artykule przestawiono sposób korekcji błędu liczników energii elektrycznej przeznaczonych do montażu na pokładzie pojazdów trakcyjnych szynowych i kołowych. Sposób ten polega na odpowiednim doborze współczynnika wzmocnienia toru prądowego licznika.
EN
The paper presents the way of correction error of watt-hour meters installed in the board rolling stock traction and wheel traction vehicle. This method based on appropriate selection amplification coefficient the meter current circuit.
Silniki elektryczne powinny mieć w fazie produkcyjnej przeprowadzane testy temperaturowe ze względu na możliwość powstawania w uzwojeniu małych wnęk powietrznych, których przewodność cieplna jest mniejsza w porównaniu z przewodnością cieplną miedzi. Na skutek tego może dojść do powstania tzw. punktu gorącego, przyśpieszającego degradację i starzenie izolacji uzwojenia. Dzięki pomiarom punkty uzwojenia, podatne na znaczne przyrosty temperatur mogą być korygowane w fazie produkcji. Przedmiotem artykułu jest układ pomiarowy przeznaczony do badań termicznych uzwojeń silników elektrycznych. Kontaktowe pomiary temperatury w silnikach elektrycznych należą do bardzo trudnych, bowiem czujniki powinny cechować się dużą dokładnością oraz bardzo małymi wymiarami. Montaż ich nie może być inwazyjny, czyli taki, po którym zostałaby zmieniona charakterystyka magnesowania silnika na skutek wykonania odwiertu w korpusie silnika do wyprowadzenia przewodów łączeniowych lub montażu sensora pomiarowego. Układy przedstawione w artykule przeznaczone są do kondycjonowania sygnałów wyjściowych czujników temperatury. Zadaniem układów jest filtracja, wzmocnienie oraz dopasowanie poziomu tych sygnałów do zakresu pracy przetworników analogowo-cyfrowych systemu mikroprocesorowego nadzorującego pracę układu pomiarowego, przeznaczonego do badań termicznych silników elektrycznych.
EN
The article presents the measuring systems for testing thermal contact single-phase induction motors with the short circuit low power. During laboratory tests it was found that such engines should be tested through the system using a miniature thermocouple circuit, combined with specialized conditioner. Such a systems as opposed to the system using resistive sensors type PT 100 is resistant to electromagnetic interference generated by the test engine AC. This fact is confirmed by laboratory tests.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.