1
Content available Power quality in the circuits of traction substation
EN
Rail transport in Poland uses direct current electric traction to power vehicles (locomotives and multiple units). It is therefore necessary to convert the AC voltage of the power system into the DC voltage of the traction system. The conversion of alternating voltage into direct voltage takes place in traction substations. Rectifier units installed at traction substations are used for this purpose. As a result, electric traction should be classified as non-linear consumers. In addition, the traction substation load changes dynamically. All this makes the electric traction a recipient generating a number of disturbances to the network. These disturbances affect the quality of electricity in the power system from which the traction substations are supplied, and the quality of energy in auxiliary and non-traction lines. The article presents the results of the analysis of measurements of electricity quality indicators recorded at selected points of the traction substation line. Parameters characterizing the quality of electricity were recorded, among others, in in the main line supplying the traction substation, non-traction needs line and auxiliary circuits. The presented article is another in a series of publications related to the assessment of the impact of DC electric traction on the power system.
PL
Transport kolejowy w Polsce wykorzystuje do zasilania pojazdów (lokomotyw i zespołów trakcyjnych) trakcję elektryczną prądu stałego. Konieczne jest zatem przekształcenie napięcia przemiennego systemu elektroenergetycznego na napięcie stałe systemu trakcyjnego. Zamiana napięcia przemiennego na napięcie stałe odbywa się w podstacjach trakcyjnych. Wykorzystywane do tego celu są zespoły prostownikowe zainstalowane na podstacjach trakcyjnych. Sprawia to, że trakcję elektryczną zaliczyć należy do obiorców o charakterze nieliniowym. Dodatkowo obciążenie podstacji trakcyjnej zmienia się w sposób dynamiczny. Wszystko to powoduje, że trakcja elektryczna jest odbiorcą generującym do sieci szereg zaburzeń. Zaburzenia te wpływają na jakości energii elektrycznej systemu elektroenergetycznego, z którego zasilane są podstacje trakcyjne oraz jakość energii w liniach potrzeb własnych i potrzeb nietrakcyjnych. Artykuł przestawia wyniki analizy pomiarów wskaźników jakości energii elektrycznej zarejestrowanych w wybranych punktach linii podstacji trakcyjnych. Parametry charakteryzujące jakość energii elektrycznej zarejestrowano m.in. w głównej linii zasilającej podstację trakcyjną, linii potrzeb nietrakcyjnych oraz obwodach potrzeb własnych. Prezentowany artykuł jest jednym z cyklu publikacji związanych z oceną oddziaływania trakcji elektrycznej prądu stałego na system elektroenergetyczny.
PL
W artykule przedstawiono wynik komputerowej symulacji pracy sieci elektroenergetycznej niskiego napięcia z generacją rozproszoną. Przedstawiono także analizę wpływu pracy instalacji fotowoltaicznych na wartości napięcia w sieci elektroenergetycznej niskiego napięcia.
PL
W artykule przedstawiono wynik komputerowej symulacji pracy sieci elektroenergetycznej niskiego napięcia z generacją rozproszoną. Przedstawiono także analizę wpływu pracy instalacji fotowoltaicznych na wartości napięcia w sieci elektroenergetycznej niskiego napięci.
EN
The article presents the results of a computer simulation of low voltage power network operation. An analysis of the influence of photovoltaic installations on voltage values in the low voltage electric power network has been presented.
PL
W artykule przedstawiono rozważania dotyczące zarządzania grupą mikroźródeł przyłączonych do sieci niskiego napięcia, w obrębie jednej stacji transformatorowej. Na podstawie przeprowadzonych analiz określono możliwy wpływ dużej liczby instalacji prosumenckich generujących moc w dolinie zapotrzebowania, na zmiany napięcia w tej sieci. Zaproponowano architekturę i algorytm lokalnego układu zarządzania grupą takich źródeł, mającego za zadanie wyeliminowanie efektu „podbicia” wartości napięcia, który może powodować negatywne konsekwencje dla odbiorców. „Niniejszy artykuł powstał w ramach realizacji projektu badawczo-rozwojowego GEKON1/O2/2014108/19/2014, pt. “Dynamiczne zarządzanie zdolnościami przesyłowymi sieci elektroenergetycznych przy wykorzystaniu innowacyjnych technik pomiarowych” finansowanego w okresie od 01.06.2014 do 31.05.2016 przez Narodowe Centrum Badań i Rozwoju oraz Narodowy Fundusz Ochrony Środowiska w ramach programu GEKON – Generator Koncepcji Ekologicznych”.
EN
The article describes the thoughts of the micro sources group management attached to the low voltage grid within one transformer substation. On the bases of carried analysis, there has been defined possible effect of large scale of the prosumer installation generating the input within the demand valley, of voltage changes of this network. The architecture and local algorithm of management system within the group of sources that are eliminating the overvoltage effect is also proposed. This process may cause negative consequences to consumers.
5
Content available remote Three-phase load imbalance enhances voltage fluctuations in distribution network
EN
The analysis presented in this paper aims at the determination of the possibilities of detecting network load imbalance on the basis of standard measurements of electric power quality in transformer stations. The imbalance of the load represented by imbalance coefficient directly affects the number of voltage events in the network. The term events used here denotes voltage dip and swell beyond the range stated in the limits. On the basis of the definition of voltage dispersion and imbalance coefficient the relation between the phenomena was established. On the basis of statistical analysis of the results of the measurements the applicability of the voltage measurements in transformer station for the determination of load imbalance in the network was assessed.
PL
Artykuł zawiera wybrane wyniki pomiaru odchyleń wartości napięcia sieci niskiego napięcia od wartości znamionowych. Analiza wyników pomiarów pozwoliła na określenie wpływu niesymetrycznego obciążenia sieci reprezentowanego przez współczynnik asymetrii napięcia na liczbę zdarzeń i głębokość zapadów napięcia występujących u odbiorców, ze szczególnym uwzględnieniem dwóch poziomów napięcia znamionowego - 220 V i 230V.
PL
W artykule przedstawiono wyniki pomiarów podstawowych parametrów jakości energii elektrycznej pomierzone w sieciach zasilających podstacje oraz obwodach potrzeb nietrakcyjnych. Pokazano wpływ dynamicznych zmian obciążenia trakcji prądu stałego na zmiany tych parametrów. Przyczynami występowania zjawisk, które decydują o jakości energii elektrycznej w sieci prądu przemiennego są: specyficzna budowa podstacji trakcyjnych prądu stałego (transformacja energii prądu przemiennego na prąd stały) oraz charakter ich obciążenia (dynamiczne zmiany obciążenia związane z prowadzeniem ruch pociągów). Do negatywnych skutków energetycznych związanych ze specyfiką systemu zasilania trakcji prądu stałego zaliczyć można m.in.: odkształcenie napięcia oraz prądu pobieranego z systemu energetyki zawodowej wywołane nieliniowym charakterem podstacji trakcyjnych, wahania napięcia w systemie zasilającym podstacje spowodowane zmianą obciążeń trakcyjnych, przekroczenia mocy wynikające z procesu rozruchu jednostek kolejowych.
EN
In this paper, results of the measurement of electric power quality parameters measured both in substation and nontraction supplying systems have been presented. The influence of dynamic change of the load of DC traction supplying system on the change of power quality parameters has been shown. On the basis of obtained measurements, it is possible to say that following factors had a major influence on the basis parameters of electric power quality: circuit of traction substation, the load of traction substation, character and variability of the load of traction substation, character and power of receivers connected to the nontraction network. Deformation of the voltage curve at the connecting point of nontraction transformer depends mainly on the current fed by traction vehicles. It is necessary to point out that nontraction receivers have a major impact on electric power quality at the low short-circuit power. According to requirements contained in the norm concerning the electric power quality, the control of electric power quality provided by the nontraction network should be carried out. Therefore nontraction receivers should satisfy requirements concerning the character and the power of installed receivers (limitation in installing unquiet receivers).