Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  zinc coated steel
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The aim of the study was to determine the possibility of joining dissimilar joints of zinc coated E275D and X5CrNi18-10 steels by braze welding process. The experiment was performed by the Puls-Arc method with argon as the shielding gas. The process was carried out using a Lincoln Electric Power Wave S500 welding device. Joints was carried out in two variants: without treatments before braze welding, and when the zinc coating was removed by mechanical means. Macro- and micro metallographic examinations and an analysis of mechanical properties of joints based on Vickers hardness distribution were carried out. The average hardness of the welds is 99 HV10. No effect on hardness of the removal of the zinc coating before braze welding was observed. For welds in the presence of a liquid metal, LME (Liquid Metal Embrittlement) cracks were observed. The results may be useful in the design of dissimilar materials joining technology using braze welding method.
PL
Celem badań było określenie możliwości łączenia złączy różnoimiennych z ocynkowanej stali E275D i stali X5CrNi18-10 metodą lutospawania. Eksperyment wykonano łukiem pulsującym w osłonie argonu. Proces przeprowadzono na urządzeniu Power Wave S500 firmy Lincoln Electric. Złącza wykonywano w warunkach bez dodatkowych zabiegów przed procesem i gdy w miejscu złącza usunięto warstwę cynku w sposób mechaniczny. Zaprezentowano wyniki badań makro- i mikroskopowych złączy oraz analizę ich właściwości mechanicznych wykonaną w oparciu o rozkład twardości w złączu. Pomiary prowadzono sposobem Vickersa. Średnia twardość w złączu wynosi 100 HV10. Nie stwierdzono wpływu usuwania powłoki cynkowej na twardość w złączach. W złączach zaobserwowano pęknięcia spowodowane kruchością w obecności ciekłych metali. Uzyskane wyniki mogą być przydatne podczas projektowania technologii łączenia materiałów różnoimiennych przy użyciu metody lutospawania.
PL
Przedstawiono trudności związane z łączeniem elementów ocynkowanych oraz omówiono wpływ cynku na przebieg procesu spawania i lutospawania elektrodą topliwą w osłonie gazów. Omówiono sposoby minimalizacji szkodliwego oddziaływania cynku na jakość połączeń. Przedstawiono jakość, własności i budowę strukturalną połączeń spawanych i lutospawanych blach stalowych.
EN
Difficulties connected with joining of zinc coated steel components and the influence of zinc on gas metal arc welding and weldbrazing processes have been presented. Minimization methods of zinc harmful effect on quality of joints have been discussed. Quality, properties and structure of welded and weldbrazed joints have been presented.
EN
The article presents the course and results of research aimed to determine the effect of the type of shielding gas on the shape of brazeweld, tensile strength and structure of braze welded joints made using Variable Polarity GMA, flux-cored consumable electrode and one of 3 types of shielding gas, i.e. Ar and Ar + 1% O₂ and Ar + 18% CO₂ mixtures. The study involved macro and microscopic examinations and tensile strength tests performed on overlay brazes and braze welded joints. The study-related tests have revealed that the use of mixtures containing active gases, especially CO₂, increases the heat input of braze welding processes and provides greater wettability of sheets to be jointed. However, the use of the mixtures mentioned above also causes greater damage to sheet coatings in braze welding areas and in some cases can even lead to the partial melting of elements being joined, deteriorating the aesthetics of joints and reducing their tensile strength.
PL
Przedstawiono przebieg i wyniki badań mających na celu określenie wpływu rodzaju gazu osłonowego na kształt lutospoiny, wytrzymałość na rozciąganie oraz budowę strukturalną złączy lutospawanych wykonanych za pomocą lutospawania elektrodą topliwą prądem przemiennym, z wykorzystaniem drutu proszkowego z wypełnieniem topnikowym oraz 3 rodzajów gazu osłonowego - Ar i mieszanin Ar + 1%O2 i Ar + 18% CO2. Przeprowadzono badania metalograficzne makroskopowe oraz mikroskopowe lutonapoin i złączy lutospawanych, a także badania wytrzymałości na rozciąganie. Badania te wykazały, że zastosowanie mieszanin z gazami aktywnymi, a zwłaszcza z CO2, podwyższa energetyczność procesu lutospawania, zapewnia też lepszą zwilżalność łączonych blach , lecz sprzyja większym uszkodzeniom powłoki blach w strefie łączenia i nadtopieniu łączonych elementów, pogarsza również estetykę połączeń i obniża wytrzymałość na rozciąganie.
4
Content available remote Fretting of the galvanized steel rope wires
PL
W artykule przedstawione są badania zużycia typu fretting, zachodzącego pomiędzy przeznaczonymi na liny stalowymi drutami ocynkowanymi. Zostały przedstawione warunki w jakich występuje zespól zjawisk zwany frettingiem. Badania eksperymentalne przeprowadzono na skrzyżowanych drutach liniarskich, dla odpowiednio dobranych częstości drgań, amplitud i nacisków. Po testach zużycia, w miejscach styku drutów, stwierdzono rozlegle odkształcenia i przemieszczenia styczne warstwy cynku. Wżery frettingowe poddano badaniom SEM i EDS. Własności mikromechaniczne powierzchni badano na Mikro--Combi-Testerze. Stwierdzono odsłonięcie powierzchni stalowej w obszarze wżeru, gdzie wysoka kinetyka oksydacji i efekt działania karbu mogą drastycznie zmniejszyć nośność ocynkowanych lin stalowych.
EN
This paper presents an investigations of the mechanism of interwire fretting wear that can operated inside cables, made with hot galvanised steel wires. A condition necessary for set of processes call fretting was presented. The twin crossed wire fretting wear experiments was carried out under realistic interwire frequency of movement, amplitude and load conditions. The large and easy tangential displacement of relatively soft zinc coating was shown at the worn surfaces. The fretting scars was analysed by SEM with EDS. Some micro-mechanical properties of materials was measured using Micro-Combi-Tester. The uncovered steel surface in the bottom of scar is the place where high kinetic corrosion and than notch effect can drastically reduce the load-carrying capacity of galvanised steel ropes.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.