W artykule omówiono podstawowe wymagania dla zasilania nowoczesnych hoteli i obiektów hotelarskich w energię elektryczną. Zwrócono uwagę na bezpieczeństwo pożarowe i zasilanie gwarantowane.
EN
The artide discusses the basie requirements for power supply modern hotels and hotel facilities with electricity. Attention was paid to fire safety and guaranteed power supply.
EN
Article presents the results of long-term testing of prototype of 64 kVA biogas cogeneration set (CHP - Combined Heat and Power), build with support of financial means from the MCP R&D program 1 2 1. Between others, the impact of fueling with biogas from the sewage treatment plant on the engine oil has been investigated. Used oil analyses unveiled adverse presence of silicon compounds, i.e. siloxanes, permissible level of which (according to MAN standard) was exceeded several times. In order to reduce these compounds, prototype biogas filter based on activated carbon has been developed. Based on initial calculations, overall efficiency of this cogeneration set is circa 70%. For the consumer needs, the entire installation is enclosed in a compact soundproof canopy. Besides environmental merits, the cogeneration set shows also economical advantages. If operating continuously, the gen-set CHP would produce electrical and heat power in an amount that its purchasing cost would be returned after about 12 months, under condition of having biogas.
PL
W pracy omówiono dotychczasową, pięcioletnią (40 000 godzin) eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracującego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę rozruchów i jego dyspozycyjność, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu, bilans energii elektrycznej i ciepła oczyszczalni oraz stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, jednostkowe zużycie biogazu przez zespół kogeneracyjny, prace serwisowe i awarie zespołu kogeneracyjnego oraz efekty ekonomiczne uzyskane z eksploatacji tego zespołu. Praca jest kontynuacją wcześniejszych publikacji [2-3, 9-15] i łącznie z nimi stanowi unikatowe kompedium wiedzy dla przyszłych eksploatatorów biogazowych zespołów CHP w postaci zbioru rzeczywistych danych eksploatacyjnych, jednego z najbardziej reprezentatywnych pod względem mocy elektrycznej (ok. 0,8 MW), biogazowego zespołu kogeracyjnego eksploatowanego w krajowych oczyszczalniach ścieków.
EN
The paper discusses five years’ (40 000 hours) commercial operation to date of the Biogas Cogeneration (CHP) Set driven with the JMS 316 GS-B.LC GE JENBACHER type engine, which has been operating in the WARTA S.A. Sewage Treatment Plant of Czestochowa since the end of December 2008. The analysis covered the CHP Set's operation and shutdown times, number of start-ups and availability, electric energy and heat generation, and average hourly electric and thermal load; the Sewage Treatment Plant's electric energy and heat balance and the degree of coverage of its electric energy and heat demand by its own production; the unit biogas consumption by the CHP Set; the service work carried out on, and failures of the CHP Set; and the economic effects gained from the operation of the Set. The study is a continuation of the previous publications [2-3, 9-15] and, jointly with them, constitutes a unique compendium of knowledge for future operators of CHP biogas sets in the form of a collection of actual operational data for one of the most representative biogas cogeneration sets operated in domestic sewage plants in terms of electric power (approx. 0.8MW).
PL
W pracy omówiono dotychczasową, trzyletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracującego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę rozruchów i jego dyspozycyjność, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, bilans energii elektrycznej i ciepła oczyszczalni oraz stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, jednostkowe zużycie biogazu przez zespół kogeneracyjny, prace serwisowe i awarie zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu. Praca jest kontynuacją wcześniejszych publikacji [3, 6, 7, 8, 9] i łącznie z nimi stanowi unikatowe kompendium wiedzy dla przyszłych eksploatatorów biogazowych zespołów CHP w postaci zbioru rzeczywistych danych eksploatacyjnych, jednego z najbardziej reprezentatywnych pod względem mocy elektrycznej (ok. 0,8 MW), biogazowego zespołu kogeracyjnego eksploatowanego w krajowych oczyszczalniach ścieków.
EN
The paper discusses three years’ commercial operation to date of the Biogas Cogeneration (CHP) Set driven with the JMS 316 GS-B.LC GE JENBACHER type engine, which has been operating in the WARTA S.A. Sewage Treatment Plant of Czestochowa since the end of December 2008. The analysis covered the CHP Set’s operation and shutdown times, number of start-ups and availability, electric energy and heat generation, and average hourly electric and thermal load; the Sewage Treatment Plant’s electric energy and heat balance and the degree of coverage of its electric energy and heat demand by its own production; the unit biogas consumption by the CHP Set; the service work carried out on, and failures of the CHP Set; and the economic effects gained from the operation of the Set. The study is a continuation of the previous publications [3], [6], [7], [8], [9] and, jointly with them, constitutes a unique compendium of knowledge for future operators of CHP biogas sets in the form of a collection of actual operational data for one of the most representative biogas cogeneration sets operated in domestic sewage plants in terms of electric power (approx. 0.8 MW).
EN
The paper discusses two years' commercial operation of the biogas cogeneration set with a GE JENBACHER engine type JMS 316 GS-B.LC, which was installed at the end of December 2008 at the WARTA S.A. Waste Treatment Plant in Czestochowa. The analysis covered the time of operation and shutdowns, the number of the start-ups of the CHP set, its operation time utilization rate, the generation of electric power and heat, the average hourly electric and thermal load of the CHP set, the electrical energy balance of the WARTA S.A. Waste Treatment Plant in Czestochowa along with the degree of coverage of the Waste Treatment Plant's electrical energy and heat demand by their own production, the Waste Treatment Plant's biogas balance, unit biogas consumption by the CHP set, the servicing of the CHP set, and the economic effects achieved from the operation of the Cogeneration Set.
PL
W pracy omówiono dwuletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracujacego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów, liczbę rozruchów zespołu CHP, stopień jego wykorzystania, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, bilans energii elektrycznej oczyszczalni i stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, bilans biogazu w oczyszczalni, jednostkowe zużycie biogazu przez zespół kogeneracyjny, serwis zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu.
PL
W artykule omówiono dwuletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracujacego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę jego rozruchów i stopień wykorzystania, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne, bilans energii elektrycznej oczyszczalni i stopień pokrycia zaporzebowania oczyszczalni na energięelektryczną i ciepło produkcją własną, bilans biogazu w oczyszczalni, jednostkowe zużycie biogazu przez zespół kogeneracyjny, serwis zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu.
EN
The paper dicsusses two years' commercial operation of the biogas cogeneration set with a GE JENBACHER engine type JMS 316 GS-B.LC, which was installed at the end of December 2008 at the WARTA S.A. Waste Treatment Plant in Czestochowa. The analysis covered the time of operation and shutdowns, the number of the start-ups of the CHP set, its operation time utilization rate, the generation of electric power and heat, the average hourly electric and thermal load of the CHP set, the electrical energy balance of the WARTA S.A. Waste Treatment Plant in Czestochowa along with the degree of coverage of the Waste Treatment Plant's electrical energy and heat demand by their own production, the Waste Treatment Plant's biogas balance, unit biogas consumption by the CHP set, the servicing of the CHP set, and the economic effects achieved from the operation of the Cogeneration Set.
PL
Dla budynków przedsiębiorstwa o zapotrzebowaniu mocy na ogrzewanie 500 kW (na przykładzie Instytutu Techniki Cieplnej w Łodzi) przeanalizowano cztery warianty układów grzewczych z pompą ciepła - z wodą gruntową lub wymiennikami gruntowymi, jako dolnymi źródłami ciepła. W jednym z wariantów do zasilania pompy ciepła wykorzystano zespół kogeneracyjny. Porównano jednostkowe i roczne koszty ciepła z dotychczasowymi kosztami z scentralizowanego źródła ciepła. Nie analizowano kosztów inwestycyjnych.
EN
For the buildings of an enterprise with heating power requirement of 500 kW (at the Institute of Heat Engineering in Łódź) four variants of heating systems with heat pump - with ground water or ground heat exchangers as the lower sources of heat were analyzed in one of the variants to supply the heat pump cogeneration system unit was used. Unit price and annual costs of heat energy were compared with costs of energy from central heat distribution network. There was no analysis of the investment outlays.