EN
The paper presents the results of experimental heat transfer and pressure drop during condensation of the single component refrigerant R134a and zeotropic mixtures R404A, R407C, and R410A in tube minichannels of internal diameter from the range 0.31–3.30 mm. The local values and the average of heat transfer coefficient and pressure drop in the whole range of the change in mass quality were measured. On the basis of the obtained test results there was illustrated the influence of the change of mass vapor quality, the mass flux density, and the inner diameter of channel on the studied parameters. These results were compared with the calculation results based on the relations postulated by other authors. The discrepancy range was ± 50%. On the basis of given test results own correlation was developed to calculate the heat transfer coefficient and pressure drop of tested refrigerants which presents the obtained results in a range of discrepancy of ±25%.
EN
This paper describes the results of experimental investigations of heat transfer during the condensation of the homogenous R134a refrigerant and zeotropic mixtures R404A, R407C and R410A in pipe minichannels with internal diameters 0.31–3.30 mm. The values of the local and average heat transfer coefficient throughout the range of changes in the vapor quality 1–0 were determined. Based on the obtained results, the effect of vapor quality, mass flux density and channel diameter changes on heat transfer coefficient was illustrated. a pronounced effect of the refrigerant properties at the heat exchange efficiency during the condensation process in pipe minichannels was indicated. The results were compared with calculations according to the correlations proposed by other authors. On the basis of the experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient, obtaining the results of compatibility tests in the range of ±20%.
PL
Autorzy pracy przedstawili wyniki badań eksperymentalnych wymiany ciepła podczas skraplania jednorodnego czynnika chłodniczego R134a oraz mieszanin zeotropowych R404A, R407C i R410A w minikanałach rurowych o średnicy wewnętrznej d = 0,31+3,30 mm. Wyznaczono wartości lokalne i średnie współczynnika przejmowania ciepła a w całym zakresie zmiany stopnia suchości (x = 1+0). Na podstawie uzyskanych wyników badań zilustrowano wpływ zmiany stopnia suchości pary czynnika x, gęstości strumienia masy G oraz średnicy wewnętrznej kanału d na wartość współczynnika przejmowania ciepła. Wskazano na wyraźny wpływ właściwości czynnika chłodniczego na efektywność wymiany ciepła podczas skraplania w minikanałach rurowych. Wyniki badań porównano z wynikami obliczeń według zależności opracowanych przez innych autorów, przy czym rozbieżności przekraczały przedział ±50%. Na podstawie uzyskanych wyników badań sporządzono własną korelację do obliczenia współczynnika przejmowania ciepła badanych czynników uzyskując zgodność z wynikami badań w zakresie ±25%.
EN
The experimental investigation results of heat transfer during homogenous R134a and zeotropic mixtures R404A, R407C and R410A refirigerants condensation in pipe minichannels with internal diameter d = 0,31+3,30 mm were presented by authors. The average and local values of heat transfer coefficient a in whole range of vapor quality x were determined. Based on the investigation results, the influence of vapor quality x, mass flux density G and internal diameter d values changes on heat transfer coefficient was illustrated. The significant influence of refrigerant properties on heat transfer efficiency during condensation in pipe minichannels was indicated. The investigation results with calculation results from other authors correlations were compared, the differences exceed the range of ±50%. Based on the experimental results, authors new correlation to calculate the local heat transfer coefficient was made. This equation gives accuracy with experimental results about ±25%.
4
EN
Abstract Liquefied petroleum gas (LPG) is a fuel which is widely applied in transport engineering. It consists of saturated hydrocarbons, especially propane, butane and other substances (less than 1 %). These two main components are used in refrigerators, air-conditioners and heat pumps as well and are known as HC 290 (propane) and HC 600a (isobutane). In recent years when ecological aspects of refrigerants application are very important for designers and manufactures LPG can be considered as substitute for R134a. Experimental results of the refrigerators using LPG show that the lowest electrical energy consumption, higher volumetric cooling capacity and lower freezer temperature can be achieved compared to R134a. But the composition of this zeotropic mixture depends on a season. During the winter the mixture consists more propane whereas during the summer butane is a dominant component of the mixture. These conditions change the characteristic parameters of the cycle. The paper presents theoretical analysis and experimental results of a pressure ratio, power consumption and COP changes depending of LPG composition and discuss with the thesis that LPG can be an appropriate long-term candidate to replace R134a in the existing and new heat pumps and refrigerators.
PL
Zastosowanie w instalacjach ziębniczych zeotropowych mieszanin substancji pochodzenia naturalnego wymaga uwzględnienia w projektowaniu procesów zjawiska nieizotermiczności przemian fazowych (poślizgu temperaturowego). Wpływa to na charakter przemian w wymiennikach, a także na zmniejszenie spadku ciśnienia czynnika roboczego podczas dławienia. Zmienia się przepustowość kapilarnego elementu dławiącego, zmniejsza stopień suchości dwufazowej mieszaniny na wylocie z kapilary i wzrasta temperatura czynnika opuszczającego rurkę kapilarną. Intensyfikacji ulegają też wszystkie osobliwości procesu obserwowane podczas dławienia czynników jednorodnych. Przedstawiono model matematyczny procesu dławienia dwufazowej, dwuskładnikowej mieszaniny zeotropowej z uwzględnieniem wszystkich aspektów przepływu. Na podstawie uzyskanych charakterystyk zanalizowano ich wpływ na parametry procesu dławienia.
EN
Capillary tubes are generally used as throttling devices in packaged units of household compressor refrigerators, air conditioners and heat pumps. Successful experience in their application into the units of the cooling capacity of more than 20 kW have also been achieved. In spite of wide use, the following problems are not yet fully explained: mathematical modelling of the throttling process at two-phase metastable f1ow, conditions of a critical f1ow, effect of heat exchange on the throttling process, capacity control end effect of the use of capillary tubes.