EN
The aim of this study was an assessment of feasibility of conversion of sewage holding (SH) tanks to rainwater harvesting (RWH) tanks in Poland. Such a conversion may partly solve the problem of water scarcity for irrigation of plants in individual small gardens and reduce tap water consumption. Seven methods of RWH tanks sizing were applied to an example of a small harvesting system of the roof area equal to the garden irrigation area of 100 m2 for three different irrigation doses. A new criterion was introduced to optimize the tank capacity. Economic optimization was provided for new RWH tanks and for the tanks adapted from abandoned SH tanks. Results obtained for a system sited in west-central Poland in an average year have shown that design capacity of RWH tanks varied markedly between sizing methods. The conversion of SH tanks to RWH tanks is profitable, especially for irrigation due to scarcity of water in relatively dry west-central regions. Conversion of individual SH tanks in a good technical state to RWH tanks is relatively simple and cheap. The potential increase in storage volume due to the conversion of individual SH tanks to RWH tanks could reach all over Poland 215–350 dam3 per year, and individually can save up to 18–25% of total annual water use.
PL
Celem pracy była ocena możliwości przekształcenia zbiorników bezodpływowych do ścieków (ZB) w zbiorniki do gromadzenia wody deszczowej (WD) w Polsce. Taka konwersja może częściowo rozwiązać problem niedoboru wody do nawadniania roślin w małych ogrodach przydomowych i zmniejszyć zużycie wody wodociągowej. Zastosowano 7 metod określania wielkości zbiornika WD na przykładzie małego systemu zbierającego opady z dachu o powierzchni równej powierzchni nawadnianego ogrodu (100 m2) oraz do alimentacji domowej instalacji wodociągowej w ilości 140 dm3/d. Wprowadzono nowe kryterium optymalizacji pojemności zbiornika, bazujące na efektywności hydraulicznej. Optymalizację ekonomiczną wykonano dla nowych zbiorników WD oraz dla zaadaptowanych z wyłączonych z eksploatacji ZB. Wyniki uzyskane dla systemu zlokalizowanego w środkowozachodniej Polsce i symulacji wykazały, że pojemność projektowa zbiorników WD różniła się znacznie między metodami wymiarowania. Konwersja ZB na zbiorniki WD jest opłacalna, szczególnie w przypadku nawadniania roślin w okresach niedoboru wody, a konwersja do instalacji wspomagającej wodociąg sieciowy jest jeszcze bardziej opłacalna, gdyż okres jej zwrotu wynosi od 2 do 6 lat. Przekształcanie indywidualnych ZB w zbiorniki WD i POŚ jest stosunkowo proste i tanie. Potencjalny wzrost pojemności retencyjnej w wyniku konwersji indywidualnych ZB na zbiorniki WD może osiągnąć w całej Polsce 215–350 tys. m3 rocznie, a indywidualnie może zaoszczędzić do 40% całkowitego rocznego zużycia wody.
PL
Wzrost zainteresowania ochroną środowiska naturalnego przyczynia się do budowy dużej liczby oczyszczalni ścieków o różnej wielkości. Wiąże się to również z budową znacznej liczby zbiorników, z reguły żelbetowych. W referacie wskazano przyczyny korozji betonu zbiorników. Podano również ogólną ich charakterystykę oraz listę błędów popełnianych podczas projektowania i wykonywania zbiorników. Przedstawiono wymagania wykonawcze, opisano kontrole wykonania konstrukcji jak również zasady odbioru robót w celu uzyskania wymaganej ich niezawodności i trwałości.
EN
The growing interest in environmental protection contributes to the construction of a large number of wastewater treatment plants of various sizes. It also involves the construction of a large number of tanks, usually reinforced concrete. The paper indicates causes of corrosion of concrete tanks. Their general characteristics as well as a list of errors made during the design and construction of tanks are also provided. Execution requirements are presented, construction controls as well as works acceptance rules are described in order to achieve the required reliability and durability.
PL
W artykule przedstawiono zagadnienia dotyczące wpływu działania sił poziomych w strefach płyt dennych na zagrożenie bezpieczeństwa żelbetowych zbiorników prostokątnych w oczyszczalniach ścieków na przykładzie bioreaktora oraz zbiornika podczyszczalni ścieków. W pierwszym przypadku, w wyniku badań in situ i analizy żelbetowego zbiornika wielokomorowego stwierdzono szereg nieuszczelnionych przecieków w miejscach powstałych rys skurczowych i szczelin dylatacyjnych w ścianach zewnętrznych. Sprawdzenie stateczności na przesunięcie ściany zewnętrznej zbiornika potwierdziło zagrożenie bezpieczeństwa (obliczenia projektowe zawierały błąd). Zalecono wzmocnienie płyty dennej w postaci wieńca wokół zbiornika. Natomiast w zbiorniku w podczyszczalni ścieków stwierdzono zjawisko ścinania w nowo wykonanej ścianie na styku z płytą denną. Awaria miała miejsce latem 2015 r., kiedy zbiornik został poddany znacznym obciążeniom termicznym, a następnie dwukrotnie obciążony wodą podczas próby szczelności.
EN
This paper presents the issues concerning the impact of horizontal forces in the ground slab zones on the safety risk of RC rectangular tanks in sewage treatment plants on the example of a bioreactor and a sewage pre-treatment tank. In the first case, as a result of an in situ testing and analysis of a RC multi-chamber tank, a number of unsealed leaks in the shrinkage cracks and expansion joints were found in the external walls. The horizontal stability verification of the external wall confirmed the threat to safety (design calculations contained an error). It was recommended to reinforce the ground slab by a rim embracing the tank. In the second instance of a tank in the sewage pre-treatment plant, a shear phenomenon in the newly made wallas found at the ground slab joint. The failure took place during the summer of 2015, when the tank was subjected to significant thermal loads, and then charged twice with water during the leaking test.
PL
W pracy omówiono uszkodzenia i przyczyny, które doprowadziły do stanu awaryjnego dwóch reaktorów biologicznych na remontowanej oczyszczalni ścieków w Wałczu. Powstałe uszkodzenia ścian i den zbiorników stworzyły zagrożenie skażenia środowiska ściekami komunalnymi. Bezpośrednią przyczyną tego stanu były popełnione błędy na etapie projektowania konstrukcji zbiorników bez zachowania odpowiednich zasad odnośnie posadowienia, rozwiązań dylatacji, zbrojenia i wymagań co do jakości betonu. W reaktorach nie zastosowano odpowiednich powłok ochronnych na betonie, co w połączeniu ze złą jakością betonu doprowadziło do całkowitej degradacji obiektów i podjęcia decyzji o ich rozbiórce z uwagi na nieopłacalny remont.
EN
Present paper discusses the damages and causes that led to the emergency condition of two biological reactors on the renovated sewage treatment plant in Walcz. Resulting damages of walls and bottom of tanks caused a risk of contamination of the environment with municipal sewage. The direct cause of this condition was mistakes/errors made at the stage of structural design of the tanks without maintaining proper rules of foundation process, construction of dilation, propositions of suitable reinforcements and concrete quality requirements. In the reactors appropriate protective coatings on a concrete were not used, which, in combination with poor quality of concrete, led to complete degradation of objects and decided to demolish them due to unprofitable repairs.
PL
W pracy omówiono przyczyny uszkodzeń ścian dwóch zbiorników – komór napowietrzania ścieków znajdujących się na terenie modernizowanej oczyszczalni ścieków w Grodzisku Wlkp. Zasadniczą przyczyną powstałych uszkodzeń było niewłaściwe rozmieszczenie dylatacji w ścianach zbiorników, zbyt małe zbrojenie poziome ścian niezabezpieczające ich przed wpływem skurczu betonu i zmian temperatury, zła jakość betonu oraz prowadzone roboty budowlane związane z budową w pobliżu nowego zbiornika. Po przeanalizowaniu kosztów naprawy zbiorników stwierdzono, że najbardziej racjonalnym rozwiązaniem będzie ich rozbiórka i budowa nowych obiektów z zachowaniem zasad współczesnej wiedzy technicznej, a do czasu podjęcia tych prac doraźne uszczelnienie spękanych ścian i ich lokalne wzmocnienie.
EN
Present paper discusses the causes of damage of walls of two tanks – aeration chambers of wastewater located in the area of modernized sewage treatment plant in Grodzisk Wlkp. The main cause of the damage was improper location of dilatation in the tank walls, too low reinforcement of horizontal walls not protect them against the effect of concrete shrinkage and temperature changes, bad concrete quality and building work carried out near the new tank. After analyzing the costs of repairing tanks, it was found that the most rational solution would be their dismantling and construction of new facilities according to principles of modern technical knowledge. The temporary sealing of cracked walls and their local reinforcement will be applied until repair works are done.
7
Content available remote Projektowanie zbiornika na nieczystości ciekłe
PL
W artykule przedstawiono proces projektowania zbiornika podziemnego na nieczystości ciekłe o pojemności ok. 10 m3 posadowionego na gruntach niespoistych (sypkich). Porównano wartości sił wewnętrznych w przypadku skrajnie różnych warunków gruntowych: piasku drobnego o ID = 0,2 oraz żwiru o ID = 0,7. Dodatkowo przeanalizowano wpływ modelu obliczeniowego podłoża na wyniki sił wewnętrznych. Opisano procedurę normową pozwalającą na kwalifikację konstrukcji, dzięki której możliwe jest określenie sposobu obliczania fundamentu na podłożu gruntowym.
EN
This paper presents the process of design of the underground septic tank with capacity of 10 m3 placed on the cohesionless soils. The authors compared the values of internal forces for opposing kinds of soils: fine sand with ID = 0,2 and gravel with ID = 0,7. Additionally, the authors analyzed the impact of computational model of the ground on the results of internal forces. The code procedure which allows to qualify the construction system is described, which can be used to determine the method of calculating the foundation on the subsoil.
PL
W artykule przedstawiono analizę stanu technicznego wielokomorowego, prostopadłościennego, przepływowego zbiornika na ścieki przemysłowe po wieloletnim okresie użytkowania. Projektowana nowa funkcja zbiornika wymagała rozebrania poprzecznych ścian wewnętrznych, co niekorzystnie zmieniło schemat statyczny zbiornika oraz rozkład sił wewnętrznych. Autorzy zaproponowali wzmocnienie zbiornika przez wykorzystanie w charakterze konstrukcyjnym stalowych elementów dawnego wyposażenia technologicznego komory zbiornika, podnosząc poziom bezpieczeństwa konstrukcji do ponadnormowego.
EN
The paper presents an analysis of the state of preservation of a multi-chamber cuboidal current industrial sewage tank after many years of its use. The designed new function of the tank has required pulling down the lateral internal walls, which adversely changed the static scheme of the tank has well as the internal force distribution. The authors have recommended the tank reinforcement making use of the steel elements of the former technological equipment of the tank chamber, in this way raising the safety parameters of the structure to the level that exceeds the norm.
PL
W artykule przedstawiono stan awaryjny żelbetowej powłoki cylindrycznego zbiornika Wydzielonej Komory Fermentacyjnej (WKF) wynikający z błędów projektowych. Przeanalizowano wytężenie powłoki zbiornika występujące podczas nieudanej próby szczelności, zwracając szczególną uwagę na wytężenie zbrojenia poziomego. Etapy napełniania odwzorowano zgodnie z zaistniałym obciążeniem, jakie wystąpiło podczas przerwanej na skutek licznych przecieków, próby szczelności. Zaprezentowano zinwentaryzowany stan zarysowania powłoki cylindrycznej przy poziomie cieczy równym około 2/3 wysokości ściany. Ponadto przedstawiono analizę numeryczną oraz przebieg realizacji autorskiego projektu wzmocnienia żelbetowej ściany cylindrycznej zbiornika WKF przy użyciu cięgien bez przyczepności.
EN
The article presents damage of the ferro-concrete structure of a cylindrical tank of a separated fermenter. The damage results from design errors. Stress of the tank’s structure that was present during the unsuccessful tightness test was analyzed, with a particular emphasis placed on the stress imposed on the horizontal reinforcing elements. The stages of filling were replicated in line with the existing load that was present during the tightness test, interrupted due to the numerous leaks. The miniaturized status of the cylindrical surface, with the liquid leveled-off at the level of 2/3 of the total height of the wall was presented. What is more, a numerical analysis was presented, along with the process of realization of an original project, the aim of which was to reinforce the ferro-concrete cylindrical wall of the tank with the use of non-grip steel rods.
11
Content available remote Analiza uszkodzeń i wzmocnienie kopuły wydzielonej komory fermentacyjnej
PL
W artykule opisano uszkodzenia żelbetowej kopuły zbiornika wydzielonej komory fermentacyjnej oraz przedstawiono propozycję jej naprawy (wzmocnienia konstrukcji) przez zewnętrzne sprężenie. Wyniki otrzymane z analizy numerycznej wykazały zbyt małą nośność w charakterystycznych przekrojach kopuły i przekroczenie dopuszczalnej szerokości rys. Dla istniejącej konstrukcji dobrano zewnętrzne sprężenie i dewiatory. Ponadto przeprowadzono analizę naprężeń w betonie kopuły zbiornika w wyniku sprężenia, uwzględniając pracę zbiornika w sytuacji awaryjnej (chwilowe przepełnienie).
EN
The paper concerns the damages of digester chamber RC dome. The proposition of tank’s repair by post-tensioning the dome with external unbonded tendons is presented. The results of FEM numerical analysis indicated deficiencies of bearing capacity in characteristic section of RC dome. Calculated cracks’ widths exceeded allowable values. Therefore, post-tensioning with external unbonded tendons is proposed as a method of dome strengthening. The influence of the suggested repair method on the stress state in the dome (during operation and emergency situation – tank overflow) is analyzed.
PL
Przedstawiono przypadek awarii wielokomorowego, żelbetowego zbiornika oczyszczalni ścieków podczas próby szczelności. Przeprowadzona analiza wykazała błędy konstrukcyjne zbiornika, które podczas eksploatacji stwarzałyby poważne zagrożenie bezpieczeństwa. Zaproponowano sposób wzmocnienia zbiornika, który został z powodzeniem zrealizowany.
EN
A description is given of a case in which a fault was found in a multi-chamber reinforced concrete tank at a waste water treatment plant during a leakage test. Analysis revealed structural design errors which would have led to a serious safety risk while the tank was in use. A method of reinforcing the tank was proposed and successfully implemented.
PL
Przedmiotem artykułu są uszkodzenia i propozycja sposobu wzmocnienia monolitycznego, żelbetowego zbiornika gminnej oczyszczalni ścieków.
EN
This articte concerns damage to a monolithic reinforced conerete tank at a municipal waste water treatment plant, and a proposed method for reinforcement of the structure.
PL
W referacie przedstawiono problemy dużej podatności na korozję stalowych zbiorników na ścieki komunalne, które w bardzo krótkim czasie, nawet w okresie gwarancji, ulegają znacznej korozji. Spośród wielu spodziewanych przyczyn korozji wskazano na wadliwie wykonaną ochronną instalację katodowo-anodową. Zaproponowano kilka sposobów naprawy ścian zbiornika, między innymi z wykorzystaniem instalacji katodowo-anodowej.
EN
The rusty tanks on communal wastewater are described in this paper. They were destructive in short time during its exploitation. There are many reasons for such destruction but the most important is the lack of cathode and anode protection. There are some solutions of repairing of tanks presented