Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 21

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  zapady napięcia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The frequent problem of voltage collapse in the distribution system can be mitigated through the application of the sensitivity-index-based optimization technique. The proposed method is used to identify those weak buses that are susceptible to voltage collapse within the distribution system. The identified weak buses are then optimally connected with distributed generation (DG). This will affect voltage improvement, power loss reduction, and general reliability of the system. A 30-bus 33kV feeder distribution network system is used to measure the efficacy of the proposed method. Buses 19, 22, and 30 have the greatest potential for voltage collapse in the system among all the selected candidate buses, according to the results. Bus 30, on the other hand, has the highest power KOS sensitivity index, making it the best position for the DG. The total active power loss (APL) of the network was reduced to 16.8% after effective implementation of the mitigation measures. The buses that were prone to voltage collapse which run below the statutory voltage limit (0.95 p.u ≤ Vi ≤ 1.05 p.u.) were also improved to a standard working level.
PL
Częsty problem zapadu napięcia w systemie dystrybucyjnym można złagodzić poprzez zastosowanie techniki optymalizacji opartej na indeksie wrażliwości. Zaproponowana metoda służy do identyfikacji tych słabych szyn, które są podatne na zanik napięcia w systemie dystrybucyjnym. Zidentyfikowane słabe magistrale są następnie optymalnie połączone z generacją rozproszoną (DG). Wpłynie to na poprawę napięcia, zmniejszenie strat mocy i ogólną niezawodność systemu. Do pomiaru skuteczności proponowanej metody stosowany jest 30-szynowy system sieci dystrybucyjnej z zasilaczem 33 kV. Zgodnie z wynikami, autobusy 19, 22 i 30 mają największy potencjał zaniku napięcia w systemie spośród wszystkich wybranych szyn kandydujących. Z kolei autobus 30 ma najwyższy wskaźnik czułości KOS mocy, co czyni go najlepszą pozycją dla DG. Całkowita utrata mocy czynnej (APL) sieci została zmniejszona do 16,8% po skutecznym wdrożeniu środków łagodzących. Szyny podatne na zaniki napięcia, pracujące poniżej ustawowego limitu napięcia (0,95 p.u ≤ Vi ≤ 1,05 p.u.), również zostały ulepszone do standardowego poziomu roboczego.
EN
The necessity of preliminary estimation of the value of voltage dip arising at starting-up of asynchronous motor commensurate in power with operating diesel-generator sets as part of the ship electric power system is justified. The model of ship electric power system with a modified in real-time mode configuration is developed. The process of direct starting-up of asynchronous motor is simulated, and the values of voltage dips for various values of voltage and time of excitation boost of the synchronous generator are determined. It is established that there are optimum values of the magnitude and time of boosting of excitation voltage of the synchronous generator, where voltage dip in the network is minimal. The obtained results enable assessing in the process of monitoring and management of ship electric power system of the possible consequences of direct starting-up of asynchronous motor on the network voltage under current conditions, and based on them deciding on whether to connect the additional diesel generator to the network or disconnect the least essential consumers of electricity from the network to provide generated capacity reserve.
PL
Zbadano możliwości zapadu napięcia w systemie okrętowtm generatora współpracującego z silnikiem diesla. Symulowano generator asynchroniczny podłączony do sieci dla różnych warunków startu. Określono optymalna wartość napięcia wspomagającego zapewniającą minimalne zapady napięcia.
PL
Zaprezentowano przykładowe charakterystyki wartości skutecznych napięć i harmoniczne napięcia zasilającego dla wybranego budynku handlowego.
EN
The article presents examples of voltages effective values and harmonics of input voltage for a selected trade building.
PL
W publikacji m.in. o lokalizacji źródeł zapadów napięcia w elektroenergetycznych sieciach zasilającychj oraz źródłach zakłóceń.
PL
Zapady napięcia występujące w sieci dystrybucyjnej są niekorzystnymi zjawiskami, które mogą w istotny sposób wpływać na pracę odbiorów prowadząc niejednokrotnie do ich nagłego wyłączenia. Jeśli tego typu wyłączenia mają miejsce w procesach technologicznych wymagających zachowania ciągłości produkcji, to często towarzyszą im duże straty finansowe. W związku z tym zasadniczym celem niniejszego artykułu jest przedstawienie problematyki zapadów napięć występujących w sieciach dystrybucyjnych oraz ich wypływu na pracę odbiorników przemysłowych.
EN
Voltage dips occurring in the distribution network are adverse phenomena, which can have a significant impact on the loads operation often leading to their sudden shutdown. If disconnections of loads occur in processes that require continuity of production they are often accompanied by large financial losses. Therefore, the primary objective of this paper is to present the issues of voltage dips occurring in distribution networks and their impacts on the industrial loads operation.
PL
W artykule przedstawiono propozycję modyfikacji wektorowego układu regulacji silnika synchronicznego z magnesami trwałymi, w celu zapewnienia wymaganego momentu obrotowego oraz utrzymania zadanych obrotów silnika podczas zapadu napięcia. Na podstawie przeprowadzonych symulacji pracy silnika synchronicznego z magnesami trwałymi stwierdzono możliwość poprawy odporności regulowanych napędów prądu przemiennego z silnikami synchronicznymi z magnesami trwałymi na zapady napięcia.
EN
This paper presents a proposal to modify the PM synchronous motor vector control system in order to provide the required torque and the reference speed of drives during voltage sags. Based on the simulations, the immunity improvement of adjustable AC drives with PM synchronous motors on voltage sags has been confirmed.
7
Content available remote Analiza pracy silnika indukcyjnego w warunkach zapadu napięcia
PL
W artykule przedstawiono propozycję modyfikacji wektorowego układu regulacji silnika indukcyjnego w celu zapewnienia wymaganego momentu obrotowego oraz utrzymania zadanych obrotów silnika podczas zapadu napięcia. Na podstawie symulacji oraz pomiarów w laboratorium stwierdzono poprawę odporności regulowanych napędów prądu przemiennego z silnikami indukcyjnymi na zapady napięcia.
EN
This paper presents a proposal to modify the induction motor vector control system in order to provide the required torque and the reference speed of drives during voltage sags. Based on the simulations and laboratory measurements of the induction motor, the immunity improvement of adjustable AC drives with induction motors on voltage sags has been confirmed.
8
Content available remote Review of Voltage Sag Source Identification Methods for Power Quality Diagnosis
EN
Voltage sag is considered as one of the most common power quality problems causing sensitive equipment to malfunction and many industrial process interruptions. Complains about the economic loss and equipment damage from industrial customers has stimulated the investigation on the voltage sag source location. As a result, many efforts have been made to know the location of voltage sags by utilizing various concepts. Generally, there are two broad categories of methods to locate voltage sags source, namely, single and multi-monitor based methods. Therefore, the purpose of this paper is to present a comprehensive review of articles that involves various methods to identify the location of voltage sag source. Accordingly, the concepts, advantages and disadvantages of these methods are discussed and tabulated for review. Although this paper does not exhibit a numerical performance comparison, most of the research publications under the subject of voltage sag source location methods have been sorted and appended for a rapid reference.
PL
Zapady napięcia są jednym z ważniejszych parametrów opisjących jakość energii. Mogą one powodować uszkodzenia urządeń i zakłócenia procesów przemysłowych. Artykuł omawia metody lokalizacji źródeł zapadów napięcia. Zaprezentowano przegląd publikacji opisujących ten problem uwypuklając zalety i wady każdej z metod.
9
EN
This paper deals with the development of an enhanced controller for investigation of dynamic voltage restorer (DVR) compensation capabilities. Two levels, 24-pulse DVR is modeled with a new control scheme to control the switch signal in the voltage sourced converter. A study on voltage sag compensation capability, harmonic elimination, effect of phase shift on DVR sizing, influence of induction motor load and effect of capacitor value on DVR performance have been investigated. Results proved that the DVR is a suitable device for maximum power quality (PQ) compensation. Thus, the developed model and controller will be useful for further power quality studies in a distribution system.
PL
Opisano ulepszony sterownik system dynamicznego odzyskiwania napięcia DVR. Przeanalizowano przypadki możliwości kompensacji zapadów napięcia, eliminacji harmonicznych oraz wpływ indukcyjności obciążenia. Symulacje potwierdziły przydatność układu w systemach poprawy jakości energii.
10
Content available remote Generation of voltage references using Multilayer Feed Forward Neural Network
EN
Among the dynamic voltage restorer (DVR) objectives, the protection of sensitive loads against voltage swell/sag voltage, as well as correction of unbalanced problems. The DVR acts as a voltage source, which is connected in series with a sensitive load and controlled to generate the required compensation voltages. Many researches were presented in literature to identify the voltage disturbance; one of them is Synchronous Reference Frame (SRF) method. This paper provides a DVR with identification method based on artificial neural network - the (MLFFN) Multilayer Feed Forward Neural Network. To investigate this novel method performance, it is confronted with the conventional (SRF) method. All of the studies have been carried out using the simulation with the MATLAB Simulink Power System Toolbox. The results of simulation study of new DVR detecting method presented in this paper are found quite satisfactory to eliminate the voltage disturbance from utility voltage.
PL
Przedstawiono dynamiczny układ przywracania napięcia DVR jako zabezpieczenie przeciw zapadom napięcia. Układ działa jako źródło napięcia połączone w szereg z obciążeniem. W artykule opisano metodę identyfikacji wykorzystującą sztuczne sieci neuronowe. Przedstawiono też symulacje systemu.
11
Content available remote Analysis of AC Contactor Model during Voltage Sag with Point-in-Wave of Initiation
EN
This paper presents the analysis of AC contactor model, its ride through capability and behaviour during voltage sag with point-in-wave of initiation using PSCAD/EMTDC simulation software. The ride-through capability curve is used to identify the sensitivity level in the AC contactor failure area. AC contactor simulation model were supplied with various type of voltage sag with point-in-wave of initiation. Simulation results are also validated with the ride through capability curve of the experimental results.
PL
Przedstawiono analizę pracy stycznika AC podczas możliwych zapadów napięcia przy wykorzystaniu symulacji z PSCAD/EMTDC. Modelowano różne stany zapadów jak też i różne pozycje stycznika.
EN
A rapid voltage sag detection method based on weighted least-squares estimation (WLSE) with harmonic models is proposed to satisfy the requirement of the dynamic voltage restorer. The covariance resetting technique is adopted to detect the voltage sag accurately and rapidly, even in condition the voltage contains considerable amount of harmonic components. The threshold of covariance resetting is larger than the steady state error between the sample and estimation of the voltage for the purpose of favorable covariance resetting only if the voltage sag occurs. The threshold of covariance resetting can be small because the steady state error will contain little harmonic components by the proposed WLSE method which have a positive impact on the detecting speed even if the depth of voltage sag is low. The algorithm has been tested under different conditions so as to verify its performance on voltage sag detection.
PL
Zaproponowano metodę szybkiej detekcji zapadu napięcia bazująca na określaniu średniej ważonej najmniejszych kwadratów. Do detekcji zapadu wykorzystuje się technikę kowariancji co umożliwia szybką detekcję nawet przy znacznej zawartości harmonicznych. (Ulepszona metoda detekcji zapadów napięcia bazująca na określaniu wartości ważonej najmniejszych kwadratów z uwzględnieniem harmonicznych)
EN
This article presents a novel method to locate the voltage sag source based on directional overcurrent (DOC) relay information. In this method the source of voltage sag is located by using the variation of magnitude of measured current positive-sequence component during sag and presag conditions and the sign of its phase-angle jump. The performance of the proposed method is compared with distance relay (DR) and phase change in sequence current (PCSC) methods by using PSCAD/EMTDC on a simulated case study. The results show the good and unique performance of the novel method in cases where only currents are recorded.
PL
W artykule zaprezentowano nową metodę lokalizacji źródła zapadu napięcia bazującej na informacji o kierunkowym przeciążeniu prądowym. Źródło zapadu napięcia jest lokalizowane na podstawie pomiaru amplitudy i fazy prądu w czasie zapadu i przed zapadem. Porównano metodę z z dotychczas stosowanymi metodami DR i PCSC.
PL
Artykuł zawiera podstawowe informacje opisujące zapady napięcia w sieci elektroenergetycznej. Na jego podstawie omówiono podstawowe zagadnienia sterowania przekształtnikiem sieciowym AC-DC. Zaprezentowano bezpośrednie sterowanie mocą z modulacją wektorową ang. Direct Power Control – Space Vector Modulated z modułem kompensacji zapadów napięcia w sieci elektroenergetycznej. Rozważania teoretyczne zweryfikowano na stanowisku laboratoryjnym wyposażonym w procesor sygnałowy DSP. Dokonano wstępnej optymalizacji kodu algorytmu sterowania, pod kątem maksymalnego wykorzystania możliwości platformy DSP.
EN
This paper presents a brief description of voltage dips in supply line. The Direct Power Control – Space Vector Modulated with voltage dips compensation module is described. Experimental results as assumptions’ verification are presented. Finally control method’s algorithm has been optimized in respect to reduce computation burden of the DSP.
EN
In electrical energy power network, disturbances can cause problems in electronic devices therefore their monitoring is fundamental to properly design the protection and compensation devices. In this paper we address the problem of disturbances’ detection by using two different signal processing methods: Wavelets and Hilbert Transform (HT). Methods were tested under different conditions of noise and harmonic distortion (THD) showing the Hilbert Transform can be used as a valid approach for this type of phenomena.
PL
W sieciach elektroenergetycznych, zakłócenia mogą powodować problemy w urządzeniach elektronicznych. W związku z tym ich monitorowanie, ma fundamentalne znaczenie dla prawidłowego projektowania urządzeń ochronnych i kompensacyjnych. W artykule podjęto problem wykrywania zakłóceń "za pomocą dwóch różnych metod przetwarzania sygnałów: falek i transformaty Hilberta (HT). Metody te były badane przy różnych poziomach szumu i zniekształceń harmonicznych (THD). Stwierdzono przydatność HT do analizy krótkich przebiegów przejściowych i zakłóceń oraz podobnych zjawisk.
EN
Custom Power Devices like the Dynamic Voltage Restorer have been applied for voltage dip mitigation in the last years. These electronic equipments need fast and reliable voltage dip detection algorithms. Such detection methodologies must be able to detect a voltage dip as fast as possible and be immune to other types of perturbations. In this paper we address the problem of voltage dip estimation by different signal processing methods such as Fourier based algorithm and Wavelet processing.
PL
W ostatnich latach odnotowano wzrost zainteresowania układami zapobiegającymi zapadom napięcia po stronie odbiorcy. Szybkie i pewne wyznaczenie początku zapadu jest kluczowym zagadnieniem dla energoelektronicznych urządzeń tego typu. Zapad powinien być wykryty możliwie szybko, jednocześnie algorytm powinien być nieczuły na inne rodzaje zakłóceń. Artykuł omawia zagadnienia wyznaczania parametrów zapadu z wykorzystaniem algorytmu bazującego na transformacie Fouriera oraz z zastosowaniem falek.
17
Content available remote Custom power devices for voltage sags mitigation: a techno-economic analysis
EN
The increased concern about the financial losses due to voltage sags and interruptions plus the advancements in power electronics technology have led to the innovation of very fast acting intervening equipment that can mitigate such disturbances. However, the high cost of these custom power devices can offset their technical benefits. In this paper, a procedure is proposed to find a compromised solution that makes technical and financial sense. A case study of an oil refinery in Alexandria, Egypt is considered to illustrate the proposed procedure.
PL
Wzrastające znaczenie ekonomiczne strat powodowanych przez zapady napięcia i przerwy prowadzą do opracowania urządzeń pozwalających na szybką interwencję. Niestety takie systemy są dość kosztowne. W artykule zaproponowano rozwiązanie kompromisowe aspektu technicznego i ekonomicznego. Analizę wykonano na przykładzie rafinerii w Alaksandrii w Egipcie.
PL
Omówiono badania i analizę zapadów napięcia występujących w układzie zasilającym 15 kV dużego zakładu przemysłowego oraz ograniczanie skutków tych zapadów.
EN
The paper discusses research and analysis of voltage dips that occur in 15 kV supplying system of large industrial plant as well as methods used to reduce them.
EN
The paper is dedicated to control conditions of a hybrid contactless current limiter aimed at the efficient mitigation of voltage dips. Basic features of the limiter, as well as its control circuit have been described. Since the fault current is detected by operation of a special short fuse incorporated in the limiter the control has to be tuned to the prearcing and arcing times of the fuse dependent on actual current and circuit conditions. It has been demonstrated that the control system based on the across-fuse voltage measurement needs relevant fast-acting sensors. Effects of timing of the limiter control on the fault current limitation have been demonstrated.
PL
W artykule przedstawiono wpływ sterowania bezstykowego ogranicznika prądów zwarciowych na ograniczanie zapadów napięcia. Scharakteryzowano podstawowe własności ogranicznika oraz układu sterowania jego pracą. Ponieważ prąd zwarciowy jest detekowany przez dedykowany superkrótki bezpiecznik sterowanie musi być dostosowane do czasu przedrukowego i łukowego topika, które zależą od aktualnej wartości prądu i aktualnej konfiguracji obwodu. Pokazano, że układ sterowania oparty na pomiarze napięcia miedzy zaciskami topika wymaga zastosowania bardzo szybkiego czujnika pomiarowego. Zaprezentowano wpływ doboru czasów sterowania ogranicznika na ograniczanie prądu zwarciowego.
PL
W artykule przedstawiono wyniki badań wpływu zapadów napięcia, powodowanych przemijającymi zwarciami doziemnymi w sieci 15 kV, powodujących znaczące przestoje linii produkcyjnej w wybranym zakładzie produkcyjnym Przeanalizowano zmiany przebiegów wartości chwilowych oraz skutecznych napięć fazowych w czasie zapadów ustalając ich wpływ na parametry decydujące o jakości energii elektrycznej. Zaprezentowano przedsięwzięte środki techniczne w układzie zasilania 15 kV w celu ograniczenia prawdopodobieństwa występowania zapadów.
EN
The results of the research works on the impact of the voltage dips, caused by transient earth faults in the 15 kV networks, effecting significant shutdowns of production lines in a selected factory have been presented in the paper. There have been analysed the changes of runs of actual values and phase effective voltages during dips; the impact of these dips on the parameters deciding of the quality of electric energy has been determined. The undertaken technical means have been presented in the supply system of 15 kV in order to reduce the probability of occurring of the dips.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.