Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  zakłócenie elektromagnetyczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper present the simulation of the transfer of electromagnetic disturbances from the primary to the secondary circuits of current transformers in CM-CM coupling in the frequency range [0.1 - 20MHz] . The primary voltage U1 of the primary winding equal to 30V was taken for the study of the two models of the current transformers in different configurations with and without screen to see its influence on the transmission of the disturbances, also to see the effect of capacitive couplings between the different CT elements. The simulation results obtained which represent the variation of the transfer function as a function of frequency gave us the maximum disturbance rate for each case.
PL
W artykule analizowano przejście zakłóceń elektromagnetycznych z uzwojenia pierwotnego do wtórnego przekładnika prądowego w zakresie częstotliwości 0.1 – 20 MHz. Analizowano też sprzężenie pojemnościowe między tymi uzwojeniami. Transmisja zakłóceń zależy od czestotliwości.
2
Content available remote Praca grupy dronów w pobliżu linii najwyższego napięcia
PL
Zbadano zachowanie się bezzałogowych urządzeń latających w pobliżu dwutorowej linii najwyższego napięcia (400kV). Szczególny nacisk położono na wpływ generowanych przez linię zakłóceń elektromagnetycznych na pracę urządzeń pokładowych (czujniki, układy sterowania) oraz na jakość transmisji danych. Wykonane eksperymenty pokazały, że lot grupy dronów wzdłuż linii najwyższego napięcia jest możliwy, lecz należy uwzględnić pewne zakłócenia, które mogą zaburzać ich wzajemną komunikację.
EN
The operation of Unmanned Aerial Vehicles (UAVs) in the vicinity of the double extra high voltage (EHV) line (400kV) was investigated. We focused on the impact of the electromagnetic interference generated by the line on the operation of on-board devices (sensors, control systems) and on the quality of the data transmission. The performed experiments showed that the fly of the drones' group along the HV line is possible, but some noise of signals, which can disturb intercommunication, should be taken into account.
3
Content available remote Estymacja okresu sygnału enkodera w warunkach zakłóceń elektromagnetycznych
PL
W artykule opisano nowy algorytm cyfrowego przetwarzania sygnału pochodzącego z enkodera pracującego w warunkach zakłóceń elektromagnetycznych. Zadaniem proponowanego algorytmu jest wykrycie pomiarów anomalnych i niwelacja ich wpływu na układ kontroli prędkości wózka spawalniczego. Proponowana metoda opiera się na modelowaniu zakłóceń w formie zmian wariancji szumu pomiarowego i wykorzystaniu podejścia wielohipotezowego oraz filtracji nieliniowej z liczonym na bieżąco prawdopodobieństwem stanu kanału pomiarowego. Przeprowadzone badania symulacyjne potwierdziły poprawność pracy proponowanego algorytmu w warunkach zakłóceń.
EN
The paper describes new digital signal processing algorithm for velocity control system which uses position encoder. The algorithm ensures immunity to outlier measurements caused by electromagnetic disturbances. The proposed method is based on nonlinear multihypotheses estimation with use of probabilities of the measurement channels state. The performance of the proposed method is verified by laboratory tests of encoder working in a welding carriage in presence of disturbances coming from a HF arc ignition process and by series of simulations. Obtained results reveled good performance of the proposed method and shows that it can preserve the normal operation of the welding carriage velocity controller in presence of electromagnetic disturbances.
EN
Electronic devices, which are used in safety systems during operation, produce an unintended electromagnetic field. It can be a source of interference to other devices and systems used in the protected premises (the concept of internal and external compatibility). The value of the individual electromagnetic field components, which are produced by safety system control panels, depend on their operating state. Within the individual operating states, these devices consume different values of currents from basic or backup power supplies. The paper presents the research results of the unintended electromagnetic field generated by the safety system control panels. Measurements were carried out for two frequency ranges – a range of extremely low frequencies ELF (0÷2) kHz as well as a range of very low frequencies VLF (2÷100) kHz. The research was conducted according to the Polish standards on the measurement of electromagnetic fields in a range of low frequencies.
PL
Urządzenia elektroniczne stosowne w systemach bezpieczeństwa podczas pracy wytwarzają niezamierzone pole elektromagnetyczne. Może ono być źródłem zakłóceń dla innych urządzeń i systemów wykorzystywanych w ochranianych pomieszczeniach (pojęcie kompatybilności wewnętrznej i zewnętrznej). Wartość poszczególnych składowych pola elektromagnetycznego, które wytwarzają centrale alarmowe systemów bezpieczeństwa, zależą od ich stanu eksploatacyjnego. W poszczególnych stanach eksploatacyjnych urządzenia te pobierają różne wartości prądów z zasilacza podstawowego lub rezerwowego. W artykule przedstawiono wyniki badań niezamierzonego pola elektromagnetycznego generowanego przez centrale alarmowe systemów bezpieczeństwa. Pomiary przeprowadzono dla dwóch zakresów częstotliwości - zakres ekstremalnie małych częstotliwości ELF (0÷2) kHz oraz zakres bardzo małych częstotliwości VLF (2÷100) kHz. Badania zostały przeprowadzone zgodnie z polskimi normami dotyczącymi pomiaru pól elektromagnetycznych w zakresie małych częstotliwości.
PL
Czujnik indukcyjny jest częścią indukcyjnego przetwornika prądu elektrycznego najbardziej wrażliwą na zakłócenia elektromagnetyczne. Nie może być on chroniony przed zakłóceniami za pomocą odpowiednich ekranów. Powinien więc mieć tak skonstruowane uzwojenia, aby zminimalizować wpływ zakłóceń elektromagnetycznych na jego pracę. W praktyce występuje duża różnorodność konstrukcji czujników indukcyjnych. Jednak nie wszystkie charakteryzują się małą podatnością na zakłócenia elektromagnetyczne. W wielu przypadkach producenci w ogóle nie podają informacji o wpływie zakłóceń na pracę czujnika. W niniejszym artykule przedyskutowano czynniki konstrukcyjne czujnika indukcyjnego odpowiedzialne za wrażliwość czujnika na zakłócenia. Przedstawiono metodykę i wyniki badań wpływu zakłóceń elektromagnetycznych na sygnał wyjściowy czujników o różnej konstrukcji.
EN
An inductance sensor is a part of an electrical current inductance transducer, which is the most sensitive on electromagnetic interferences. It can't be protected against interferences using proper shield. So its winding ought to be right constructed to minimize electromagnetic interferences on operation of an electrical current inductance sensor. In practice, inductance sensor construction is very diversified. However, not all of them characterize low susceptibility on electromagnetic interferences. In many cases, producers don't gave a description of interference influence on sensor operation. In the article, construction factors of a inductance sensor are discussed, which are responsible for sensor sensitivity on interferences. The methodology and laboratory test results of electromagnetic interference influences on output signal of different constructed sensors are presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.