The paper presents the results of the analysis of a real disturbance that took place in one of the Polish power plant substations. The fault was caused by the short-circuit that occurred near the power plant bus-bars. As a consequence, change in the power grid configuration occurred and one of two generators working in the power plant lost the synchronism. As a result of power swings, the unwanted operation of the unit distance protection occurred. This caused unwanted tripping of that unit. The paper gives a shortened analysis of the impedance trajectories at the time of the disturbance.
PL
W artykule przedstawiono wyniki analizy zakłócenia, jakie miało miejsce w jednej ze stacji przyelektrownianych, do której przyłączone były dwa bloki dużej elektrowni systemowej. Zdarzenie zostało wywołane zwarciem w polu transformatora łączącego szyny 110 kV i 400 kV tej stacji. W jego następstwie doszło do zmiany konfiguracji sieci, która doprowadziła do utraty synchronizmu jednego z generatorów, a ostatecznie do całkowitego wyłączenia jednego z bloków elektrowni po zbędnym działaniu zabezpieczeń w czasie kołysań mocy.
EN
This paper presents the problem of the risk of an unnecessary tripping of a generation unit’s underimpedance protection functions in circumstances of generator power swings following elimination of long-lasting fault in the external power grid. The fi rst part describes typical solutions of a generator impedance protection function (21e) and unit distance protection function (21s). Starting characteristics of these protection functions are shown, as well as their typical operating logics and ways of calculating their settings. Then exemplary (the most common) solutions of unit under-impedance relays power swing blocking functions are described. Following this introduction, the issues of the threat of unnecessary operation of fast-tripping protection zones of 21e and 21s protection functions are described, which arises in the circumstances of generator asynchronous power swings occurring after elimination of long-lasting faults in the grid supplied by the power unit. The paper also shows that the available power swing blocking functions may not be able to correctly detect the described conditions, thus allowing the unnecessary operation of under-impedance relays. How an impedance calculation algorithm aff ects the impedance trajectory seen by a protection relay is also presented.
PL
W artykule przedstawiono problem ryzyka zbędnego działania zabezpieczeń podimpedancyjnych jednostki wytwórczej, w czasie kołysań mocy następujących po długo likwidowanych zwarciach w sieci zewnętrznej. W pierwszej części opisano zabezpieczenie impedancyjne generatora (21e) i odległościowe bloku (21s). Pokazano charakterystyki rozruchowe, logiki działania i sposób nastawiania tych zabezpieczeń. Następnie opisano przykładowe (najczęściej stosowane) rozwiązania blokad kołysaniowych zabezpieczeń podimpedancyjnych bloku. Po powyższym wprowadzeniu opisano problematykę zagrożenia zbędnym działaniem szybkodziałających stref zabezpieczeń 21e i 21s, jakie powstaje w chwili rozwijania się asynchronicznych kołysań generatora, następujących po przedłużającej się likwidacji zwarć w sieci, na którą pracuje blok. W artykule pokazano też, że dostępne blokady kołysaniowe mogą nie być w stanie poprawnie wykryć opisywanej sytuacji, dopuszczając do zbędnego działania powyższych zabezpieczeń. Pokazano też, jak na trajektorię impedancji widzianą przez przekaźnik wpływa zastosowany algorytm wyznaczania impedancji.