EN
The development of a mathematical model of a three-phase ultrahigh voltage transmission line with two overhead ground wires is presented in the paper. The mathematical model is based on differential equations of state of a long line with partial derivatives in the matrix-vector form. The boundary conditions of the second kind (Neumann's conditions) are used, which enables obtaining functions of unknown coordinates of the overhead ground wires mode at the beginning and at the end of the voltage transmission line to solve the transmission line equation. Some results of computer simulations of transients during switching on and a single-phase short circuit of the line are presented in the form of corresponding graphic functions of its mode coordinates.
PL
W artykule przedstawiono model matematyczny trójfazowej linii elektroenergetycznej ultra wysokiego napięcia z dwoma przewodami odgromowymi. Model matematyczny wykorzystuje równania różniczkowe o pochodnych cząstkowych elektromagnetycznej długiej linii w postaci macierzowo-wektorowej. Jako warunki brzegowe wykorzystano warunki drugiego rodzaju (warunki Neumanna), co z kolei pozwoliło obliczyć przebiegi napięcia i prądu na początku i na końcu linii elektroenergetycznej. Wyniki symulacji komputerowej stanów nieustalonych podczas załączania linii oraz zwarcia jednofazowego w jej końcu przedstawiono w postaci rysunków.
PL
Artykuł poświęcony jest obliczeniom impulsowych prądów wysokiej częstotliwości, przepływających przez uziemienia urządzeń wysokiego napięcia podczas przełączeń oraz zwarć. Znajomość wartości tych prądów jest niezbędna do oceny kompatybilności elektromagnetycznej w elektrowniach i podstacjach, pod kątem zakłóceń podczas przełączania i zwarć. W artykule przeanalizowano obowiązujące standardy, wyniki pomiarów oraz obliczeń prądów impulsowych wysokiej częstotliwości w urządzeniach o napięciu znamionowym od 6 kV do 35 kV, które to nie są ujęte w w/w standardach. Zależności prądów impulsowych wysokiej częstotliwości, rozchodzących się przez uziemienia podczas przełączania i zwarć w urządzeniach wysokiego napięcia, określa się w zależności od specyficznej rezystancji elektrycznej ziemi i konstrukcji tych urządzeń. W artykule podano zalecenia dotyczące włączenia prądów impulsowych wysokiej częstotliwości do standardu „Wytyczne dotyczące projektowania urządzeń uziemiających sieci 10-20 kV z rezystancyjnie uziemionym punktem neutralnym” organizacji „Zjednoczona spółka energetyczna” S.A. (Moskwa).
RU
V stat’е rassmotreny voprosy ocenki vеličiny vysokočаstnogo impul’snogo toka, rastekaûŝеgоsâ po zazemlâûŝеmu ustrojstvu pri komputaciâh i korotkih zamykaniâh оborudovaniâ vysokogo naprâženiâ. Ukazannaâ vеličina neobhodima dlâ оcеnki êlektromagnitnoj obstanovki na podstanciâh i êlektrostanciâh v čаsti vypolneniâ rasčёtov konduktivnyh pomeh pri komputaciâh i korotkih zamykaniâh oborudovaniâ vysokogo napraрâžеniâ. V stat’е privedёn analiz normativnoj dokumentacii, rezul’taty izmerenij i rasčёtov vеličiny vysokočаstnogo impul’snogo toka v êlektroustanovkah 6-35 kV, otsutstvuûŝеj v normativnoj dokumentacii. Оpredeleny zavisimosti vеličiny vysokostatnogo impul’snogo toka, rastekaûŝеgosâ pо zazemlâûŝеmu ustrojstvu pri komputaciâh i korotkih zamykaniâh oborudovaniâ vysokogo napraženiâ, ot veličiny udel’nogo êlektričеskogo soprotivleniâ grunta i konstruktivnogo ispolneniâ raspredelitel’nyh ustrojstv. Privedeny rekomendacji po vklûčеniû vеličiny vysokočаstnogo impul’snogo toka v standart organizacii «Меtodičеskiе ukazaniâ pо proektirovaniû zazemlâûŝih ustrojstv setej 10-20 kV s rezistivno zazemlёnnoj nejtral’û» АО «Оbʺеdinёnnaâ ênergetičеskajâ kompaniâ» (г. Moskva).
EN
In our experiment the electrical parameters that affect early somatic embryos (ESEs) were investigated. High voltage was generated by a special high voltage generator. High voltages ranging from 5 to 20 kV and frequency of 1 Hz were applied longitudinal and transversal directly on the Petri dish with 2 days old ESEs of Picea abies for periods of 3 hours every day. One Petri dish was placed directly on top of the high voltage generator and on the other Petri dish were fixed two copper plates for transmission of high voltage. Petri dishes were exposed to high voltage for 14 days. After this time, the influence of high voltage was evaluated. To evaluate the experiment were used biological and chemical methods, which confirmed the changes in the growth of ESEs.
PL
W naszym eksperymencie badane były parametry elektryczne, które wpływają na wczesne zarodki somatyczne (ESE). Wysokie napięcie wytworzono za pomocą specjalnego generatora. Wysokie napięcie, z przedziału od 5 do 20 kV i częstotliwości 1 Hz przykładano podłużnie i poprzecznie bezpośrednio do szalki Petriego z 2 dniowymi wczesnymi zarodkami somatycznymi Picea abies, codziennie na okres 3 godzin. Jedną szalkę umieszczano bezpośrednio na górnej części generatora wysokiego napięcia, a na drugiej szalce umieszczono dwie płytki miedziane do przenoszenia wysokiego napięcia. Szalki Petriego poddano działaniu wysokiego napięcia przez 14 dni. Po upływie tego czasu oceniano wpływ wysokiego napięcia. Do oceny zastosowano metody biologiczne i chemiczne. Potwierdziły one zmiany we wzroście wczesnych zarodków somatycznych (ESE).
PL
W artykule przedstawiono wybrane aspekty analizy koordynacji izolacji wykorzystywane w praktyce projektowania stacji wysokich i najwyższych napięć. Omówiono główne założenia typowych analiz przepięciowych oraz przedstawiono metody obliczeniowe wspomagające proces poprawnego doboru środków ochrony odgromowej. Przedstawiono metody modelowania narażeń przepięciowych oraz modele poszczególnych elementów systemu, istotnych z puntu widzenia koordynacji izolacji. Szczególny nacisk położono na uwzględnienie zjawisk nieliniowych oraz charakterystyk częstotliwościowych, pozwalających na uzyskanie wymaganej dokładności obliczeń. Przedstawiono wyniki przykładowej analizy wpływu długości linii kablowej na wartości przepięć występujących w miejscu zainstalowania transformatora. Analizę przepięciową przeprowadzono dla schematu jednokreskowego typowej stacji rozdzielczej wysokich napięć w izolacji gazowej typu SF6, dla której przyjęto typowe parametry konstrukcyjne linii napowietrznych i kablowych, parametry konstrukcji wsporczych linii napowietrznych, oraz modele aparatów i urządzeń stacji wraz z doprowadzeniami, w szczególności modele transformatorów oraz ograniczników przepięć. Dla ograniczników przepięć dokonano oceny skuteczności i niezawodności ograniczników, związanej ze zdolnością ograniczników do pochłaniania i skutecznego odprowadzania energii wydzielanej podczas zadziałania, oraz pozwalającej na weryfikację poprawności doboru ograniczników dla pracy w danych warunkach przepięciowych. Przedstawiona w pracy analiza wskazuje, że połączenia kablowe mogą w znaczny sposób zmieniać narażenia powstałe w wyniku przepięć atmosferycznych w linie dochodzące do stacji, a tym samym wpływać na narażenia napięciowe, jakim w trakcie eksploatacji poddawane są układy izolacyjne aparatów i urządzeń.
EN
In the paper practical aspects of insulation co-ordination analyses are presented for high and ultra high voltage Gas Insulated Switchgear substations. Modeling methods are elaborated for proper selection of overvoltage protection measures, such as surge arresters, overhead lines towers grounding system, and line insulators chain lengths. The methods of lightning surges and substation equipment modeling were presented with special interest in modeling of nonlinear phenomena and high frequency characteristics, allowing for the required accuracy of the simulation results. The results for exemplary insulation co-ordination analysis are presented, showing the cable line impact on the substation overvoltages. The analysis was performed for a Single Line Diagram of an exemplary typical High Voltage GIS substation, for which a typical configuration and parameters of the elements have been assumed: overhead lines, substation apparatus, transformers and surge arresters. For the surge arresters, the analysis of the arresters reliable and efficient energy dissipation was analyzed, which allowed for evaluation and verification of proper selection and operation of the equipment in given voltage stress conditions and the assumed substation layout. The analyses presented in the paper shows that the cable line connections within or between substations have significant impact on overvoltages, which can threaten insulation system of transformers and can also influence selection of number and location placement of the surge arresters.
PL
Przedstawiono zasady ochrony przeciwporażeniowej w liniach napowietrznych wysokiego napięcia, zawarte w szczególności w aktualnej normie PN-EN 50341-1:2013-03E. Podobnie jak poprzednio, nie określa ona wymagań odnośnie do ochrony podstawowej (ochrony przed dotykiem bezpośrednim). Formułuje natomiast wymagania w zakresie ochrony przy uszkodzeniu (ochrony przy dotyku pośrednim), które w dużym stopniu zależą od miejsca posadowienia słupa. Na przykład, z punktu widzenia ochrony przeciwporażeniowej, nie określa się wartości rezystancji uziemienia ani największych dopuszczalnych napięć dotykowych dla słupów na terenach, gdzie rzadko przebywają ludzie (tereny leśne, niezabudowane), jeżeli po zwarciu doziemnym linia jest samoczynnie wyłączana. Omówiono również problem zagrożenia porażeniowego pochodzącego od napięć indukowanych w liniach kablowych ze współosiowymi żyłami powrotnymi. Zaprezentowano zasady kontroli instalacji uziemiającej w liniach wysokiego napięcia. Podano przykład oceny skuteczności ochrony przeciwporażeniowej w linii o napięciu 15 kV.
EN
Standard PN-EN 50341-1:2013-03E defines pinciples of protection against electric shock in high voltage overhead lines. Similarly as in its previous version, requirements for basic protection (protection against direct contact) are not included in this standard. Requirements for fault protection (protection against indirect contact), which basically depend on towers location, are introduced. For example, if the earth faults are automatically disconnected, resistance to earth and touch voltages are not limited for locations where towers are not freely accessible or where access by people will be rare (forest area, open countryside). Shock hazard caused by induced voltages in cables is described as well. Moreover principles of verification of the earthing system in high voltage power lines are presented. An example of the evaluation of protection against electric shock in the 15 kV line is also considered.
EN
In theory and experimentally a method of fuel options energy efficiency rise due to an activation of burning reaction molecules-reagents under high voltage electric field action is grounded. A variant of the technical realization of the offered method is described.
EN
The goal of the Nanocafe project is preparation of a new type of cold cathode based on nanocomposite material that is nanostructural carbonaceous film. A special high voltage direct current power supply was designed and constructed. This power supply is used to power and test nanocarbon electron emitters. This device consists of four sections, all with a common cathode. The range of output voltage is as follows: section HV I from 0 V to 20 kV, section HV II from 0 V to 12 kV, section HV III from 0 V to 5 kV and section LV from -200 V to 0 V. Maximal output current for each section is 5 mA. Output voltage and current is measured for each section separately. Due to the fact that the power supply is to be used for cold emission experiments it was constructed to be resistant to short circuit between any of outputs or between an output and common cathode.
PL
Celem projektu Nanocafe jest opracowanie nowego typu katody do zimnej emisji elektronów, wykonanej na bazie nanomateriatów węglowych. W ramach projektu został zaprojektowany i wykonany specjalny zasilacz wysokonapięciowy. To urządzenie jest wykorzystywane do zasilania i testowania emiterów elektronów wykonanych na bazie nanostruktur węglowych. Zasilacz składa się z czterech sekcji, wszystkie ze wspólna katodą. Napięcie wyjściowe poszczególnych sekcji jest następujące: sekcja WN II od 0 V do 20 kV, sekcja WN II od 0 V do 12 kV, sekcja WN III od 0 V do 5 kV, sekcja NN od -200 V do 0 V. Maksymalny prąd wyjściowy każdej sekcji wynosi 5 mA. Napięcie i prąd wyjściowy każdej sekcji jest mierzony oddzielnie. Ze względu na przeznaczenie zasilacza do eksperymentów z zimną emisją, został on wykonany tak, aby zwarcia pomiędzy wyjściami dowolnych sekcji nie powodowały uszkodzenia urządzenia.
PL
Zestykowi łącznika elektrycznego uzyskiwanego w wyniku zderzenia się styków, towarzyszy przejściowy proces drgań mechanicznych zestyku. Ma wówczas miejsce przemiana energii kinetycznej układu na energię potencjalną sprężystą, a następnie energii potencjalnej na energię kinetyczną ruchu zwrotnego styków. Cześć energii, która została nagromadzona w stykach i w elementach sprężystych może wywoływać odskoki styków. W czasie odskoków styków zapala się łuk elektryczny, powodując uszkodzenie powierzchni styczności styków, które jest zależne od wartości natężenia prądu i czasu i trwania rozwarcia styków. Istnienie i przebieg odskoków styków zależy przede wszystkim od siły docisku i prędkości schodzenia się styków, a także od materiału i masy styków. Odskokom styków łączników można zapobiec lub je ograniczyć przez stosowanie dużego docisku początkowego zestyków, zmniejszenie prędkości schodzenia się styków, a także przez częściowe rozpraszanie energii kinetycznej układu ruchomego i ukształtowanie powierzchni styczności styków.
EN
Electric contact in switches, obtained as a result of contact impact, accompanies transient process of contact mechanical vibration. In that time takes place the kinetic energy conversion of system into electric strain energy of contact adverse movement. Part of energy, which is cumulated in contacts and flexible elements, may result in contact bouncing. During contact bouncing fault arc appears causing contact surface deterioration that depends on current density value and time duration of contact opening. Existence and character of bouncing mainly depends on pressing force, contact breaking velocity, contact material and contact mass. Contact bouncing phenomenon can be prevented or limited by applying heavy pressure force, decreasing of contact breaking velocity and also by partial kinetic dispersion of movable contact and contact surface shaping too.