Heat transfer processes that occur when working the ground-air heat exchanger of geothermal ventilation system are considered in this article. The heat balance in the elementary volume of ground-air heat exchanger is proposed on the basis of thermophysical processes. The main factors that affect the process of heat transfer between the outside air and soil was been determined. Initial conditions, which can be used in mathematical and physical modelling of horizontal ground-air heat exchangers for geothermal ventilation systems were selected article presents the experimental study for determining the intensity of radiant energy in the zone irradiated by infrared heaters with their parallel arrangement in relation to the distance between them.
PL
W artykule rozpatrzono procesy wymiany ciepła zachodzące podczas pracy w gruntowym wymienniku ciepła geotermalnego systemu wentylacji. Na podstawie procesów cieplno-fizycznych zaproponowano model bilansu cieplnego w elementarnej objętości gruntownego wymiennika ciepła. Określono główne czynniki, które wpływają na proces wymiany ciepła między gruntem i powietrzem zewnętrznym. Wyznaczono warunki początkowe, które mogą być wykorzystane przy matematycznym i fizycznym modelowaniu poziomych gruntownych wymienników ciepła w systemach wentylacji geotermalnej.
2
Content available The geothermal ventilation of passive house
EN
Reduction of dependence on expensive imported energy resources causes the need to use energy-saving technologies at construction of the new and renovation of existing buildings. Thermal insulation of facades and the use of sealed windows are widely used to reduce the load on the heating system now. However, the lack of supply of fresh air through leaks in the outer fence negatively affects the hygiene indicators of indoor air. Design of supply-exhaust ventilation is a must for maintaining regulatory of air quantity and improving air quality in rooms of passive houses. Reduce of the load of the ventilation system allows the use of thermo ground-air heat exchangers. This article describes the possibility of using geothermal ventilation in the passive house by the ground-air heat exchangers.
PL
W celu zmniejszenia kosztów za import energii zaleca się stosowanie energooszczędnych technologii w nowo powstałych, a także istniejących modernizowanych budynkach. Dobra izolacja cieplna elewacji i szczelne okna przyczynią się do zmniejszenia zużycia ciepła w użytkowanym obiekcie. Jednak brak świeżego powietrza ma ujemny wpływ na jakość powietrza w pomieszczeniach. Stąd też zastosowanie wentylacji nawiewno-wyciągowej jest gwarancją poprawy jakości powietrza w budynkach pasywnych. W artykule opisano możliwość zastosowania wentylacji geotermalnej z wykorzystaniem gruntowych wymienników ciepła w budownictwie pasywnym.