Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 78

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  współczynnik mocy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
EN
An approach to simulation modeling of traction electric drives of electric locomotives with collector engines is proposed which based on taking into account the nonlinear nature of the magnetic characteristic in electric motors, the inductances of the armature and the excitation winding of the electric motor, the nonlinearity of the volt-amperage characteristics of the rectifier unit and the features of the operation of the stage control system of the electric drive.
PL
Zaproponowano podejście do modelowania symulacyjnego elektrycznych napędów trakcyjnych lokomotyw elektrycznych z silnikami kolektorowymi, oparte na uwzględnieniu w silnikach elektrycznych nieliniowości charakterystyki magnetycznej, indukcyjności twornika i uzwojenia wzbudzenia silnika elektrycznego, nieliniowości charakterystyki napięciowo-napięciowej zespołu prostownikowego oraz cech działania układu sterowania stopniowego napędu elektrycznego.
PL
Szereg obiektów zasilanych energią elektryczną charakteryzuje się niesymetrycznym poborem mocy w każdej z faz. Prowadzi to do wystąpienia problemów w zakresie kompensacji mocy biernej. Pojawiają się również sytuacje, gdzie pobór mocy na każdej z faz może wyróżniać się innym charakterem pobieranej mocy biernej. Wykorzystanie statycznych generatorów mocy biernej pozwala na realizację kompensacji w układach z asymetrią obciążenia, zarówno w zakresie charakteru mocy kompensowanej, jak i jej wartości, różnych dla każdej z faz.
EN
A number of facilities supplied with electricity are characterized by asymmetrical power consumption in each phase. This leads to problems in terms of reactive power compensation. Problems also arise where the power consumption on each phase can be distinguished by the different character of the consumed reactive power. The use of static reactive power generators makes it possible to implement compensation in systems with load asymmetry, both in the character of the compensated power, as well as its values, different for each phase.
PL
Ze względów ekonomicznych i technicznych ważnym elementem pozostaje utrzymanie właściwego bilansu mocy biernej. Bilans ten może być wyrażony przez wykorzystanie wielkości w postaci współczynnika mocy cos φ. Zapewnienie właściwej wartości tego współczynnika pozwala spełnić wymagania stawiane przed służbami utrzymania ruchu. W artykule przedstawiono wyniki pomiarów mocy biernej w układzie, gdzie do kompensacji mocy biernej wykorzystywany jest Statyczny Generator Mocy Biernej.
EN
For economic and technical reasons, it remains important to maintain a proper reactive power balance. This balance can be expressed by using a quantity in the form of power factor cos j. Ensuring the correct value of this coefficient allows you to meet the requirements for maintenance services. The article presents the results of reactive power measurements in a system where a Static Reactive Power Generator is used to compensate for reactive power.
PL
W pracy przedstawiono wyniki pomiarów ilustrujących właściwości wybranych lamp z punktu widzenia sieci elektroenergetycznej. Do badań wybrano lampę halogenową, świetlówkę kompaktową oraz 3 różne lampy LED. Przedstawiono zastosowany układ pomiarowy oraz zmierzone przebiegi czasowe oraz widma częstotliwościowe prądu zasilającego badane lampy. Wyznaczono i przedyskutowano wartości wybranych parametrów charakteryzujących wpływ tych lamp na sieć elektroenergetyczną.
EN
The paper presents the results of measurements illustrating the properties of selected lamps from the point of view of the power grid. A halogen lamp, a compact fluorescent lamp and 3 different LED lamps were selected for the investigations. The applied measuring system as well as the measured waveforms and frequency spectra of the current supplying the tested lamps are presented. The values of selected parameters characterizing the influence of these lamps on the power grid were measured and discussed.
5
Content available remote Tyrystorowy sterownik mocy Thyro-PX. Urządzenie o wielu możliwościach
PL
Podstawową funkcją Thyro-PX jest regulacja mocy na odbiorniku poprzez zmianę napięcia statecznego na wyjściu. Tę funkcje można zrealizować poprzez regulację zarówno napięcia prądu (U, U2), jak i bezpośrednio mocy (P), stosując tryb wycinania pełnych okresów sinusoidy TAKT [...]
6
Content available remote Zastosowanie filtrów pasywnych do eliminacji wyższych harmonicznych prądu
PL
W artykule przeanalizowano zagadnienia związane z jakością energii elektrycznej w instalacjach oświetleniowych z nowoczesnymi źródłami światła. Rozpoczęto od analizy metodologii obliczania parametrów energii w warunkach odkształconych przebiegów prądów i napięć. Następnie przeprowadzono analizę wyników pomiarów uzyskanych dla wybranych opraw oświetleniowych. Na koniec zaproponowano rozwiązanie umożliwiające poprawę jakości energii elektrycznej poprzez zastosowanie pasywnych filtrów rezonansowych.
EN
The article analyzes issues related to the quality of electricity in lighting installations with modern light sources. It began with an analysis of the methodology for calculating energy parameters under distorted current and voltage waveforms. Then, the analysis of the measurement results obtained for the selected lighting fixtures was carried out. Finally, a solution was proposed to improve the quality of electricity through the use of passive resonant filters.
PL
W artykule pokazane zostały wybrane obliczenia dla układu napędowego z napięciowym przemiennikiem częstotliwości i silnikiem klatkowym o mocy 20 kW. Dla przykładowego modelu układu napędowego zostały pokazane wybrane wyniki badań symulacyjnych. Słowa kluczowe: przemiennik częstotliwości, układ napędowy, współczynnik mocy, ograniczenie harmonicznych, filtr RFI.
EN
The artide presents selected calculations of components for a drive system with a voltage frequency converter and a squirrel-cage motor with a power of 20 kW. Selected results of simulation tests have been presented for the exemplary model of the drive system.
PL
Jednym z elementów branych pod uwagę podczas analizy pracy trójfazowego obwodu elektrycznego jest symetria jego prądów fazowych. Brak takiej symetrii powinien wpływać na obniżenie wartości współczynnika mocy obwodu, sygnalizując w ten sposób nieoptymalną transmisję energii ze źródła do obciążenia. Do obliczenia współczynnika mocy wymagana jest znajomość mocy pozornej. Znane są trzy sposoby obliczania wielkości tej mocy, które – w ogólnym przypadku – mogą dawać różne wyniki liczbowe. W artykule pokazano przykład niesymetrycznego obciążenia trójfazowego, które – w zależności od przyjętej definicji mocy pozornej – charakteryzowane jest różnymi wartościami współczynnikami mocy. Pokazano możliwość zoptymalizowania pracy takiego obwodu, również o zmiennej konfiguracji i zmiennej mocy czynnej, poprzez zastosowanie energetycznego równoległego filtru aktywnego.
EN
Symmetry of source phase currents should be considered when analyzing the operation of a three-phase electric circuit. Imbalance of these currents should reduce the value of the power factor of the circuit, thus signaling non-optimal energy transmission through the supply line. To calculate the power factor, it is necessary to know he apparent power. There are three methods of calculating this power. Unfortunately, they may lead to different numerical results. The article presents an example of an unbalanced three-phase load, which – depending on the used definition of apparent power – may be characterized by various numerical values of power factors. Some possibility of improving the operation of such a circuit with the use of a parallel active filter has been shown.
PL
Korekta współczynnika mocy instalacji zapewnia szereg korzyści techniczno-ekonomicznych, zwłaszcza obniżenie rachunków za elektryczność. Kompensacja współczynnika mocy pozwala na zastosowanie mniejszych transformatorów, rozdzielnic i kabli itp. oraz na zmniejszenie strat mocy i spadku napięcia w instalacji.
PL
Farmy wiatrowe, przyłączone do sieci dystrybucyjnej 110 kV, umożliwiają realizację zadań zgodnych z wymogami IRiESP/IRiESD. Farmy te mogą zatem regulować poziom generowanej mocy czynnej, generowanej lub pobieranej mocy biernej, utrzymywać stałą wartość współczynnika mocy a także napięcia w punkcie przyłączenia. Powyższe właściwości farm są już i powinny być w przyszłości coraz częściej wykorzystywane przez operatorów sieciowych (OSP, OSD) w różnych stanach pracy krajowego systemu elektroenergetycznego (KSE). W artykule zostały zaprezentowane aktualne możliwości sterowania farmami wiatrowymi z CDM ENEA Operator przyłączonymi do sieci dystrybucyjnej 110 kV w zakresie regulacji mocy biernej i stałego współczynnika mocy. Przedstawiono przykłady praktycznego zastosowania tych trybów regulacji farmą.
EN
Wind farms connected to the 110 kV distribution network enable implementation of the tasks in accordance to IRiESP/IRiESD requirements. Therefore, these farms can regulate level of the active power generation, reactive power generation and consumption, maintain constant power factor as well as voltage at the connection point. The above wind farm properties are and should be used in the future more and more often by network operators (OSP, OSD) in various operating states of the national power system (NPS). This article presents current capabilities of wind farm control from CDM ENEA Operator which are connected to the 110 kV distribution network, in terms of reactive power control and constant power factor. Examples of practical usage of these wind farm regulation modes are presented.
EN
The article analyses theoretical and practical solutions of reactive power compensation in the power grid of 25 kV, 50 Hz of the catenary. The article presents theoretical and practical studies (by providing circuits for connecting capacitor banks, structural circuits diagrams for the automatic control reactive power level, and calculating the parameters of capacitor banks) for the compensation of reactive power.
12
EN
The paper presents the concept, implementation and operational effects of the multi-servers automatic reactive power compensation system in 6 kV industry electrical power grid. As controlled reactive power compensators were used synchronous motors, capacitors’ banks and passive filters of higher harmonics available in the power grid of the plant. System of communication and collaboration of control servers with databases was disclosed. Use of events technology of Firebird database was discussed. Clients’ application for industry grid state and compensation system monitoring were presented. Results of operation and planned modernization of the system was presented.
PL
W artykule przedstawiono koncepcję, realizację praktyczną oraz efekty działania wieloserwerowego systemu automatycznej kompensacji mocy biernej w przemysłowej sieci elektroenergetycznej 6 kV. Jako kompensatory mocy biernej wykorzystane zostały silniki synchroniczne, baterie kondensatorów i pasywne filtry wyższych harmonicznych pracujące w zakładzie. Przedstawiono system informatyczny i współpracę z bazą danych. Omówiono wykorzystanie technologii zdarzeń bazy danych Firebird w prezentowany rozwiązaniu. Przedstawiono oprogramowanie klienckie wykorzystywane do monitorowania pracy systemu i stanu sieci elektroenergetycznej. Przedstawiono przykładowe efekty działania oraz propozycje dalszych prac związanych z modernizacją systemu.
13
Content available remote Voltage mode control DCM HSD-CIB PFC converter for HB-LED lighting applications
EN
High-brightness light emitting diodes (HB-LEDs) are gaining immense attention from the angle of both residential and industrial applications, owing to their advanced futures of longevity, compact size, high efficacy and eco-friendly nature. To meet advanced future requirements, the LED driver should be robust and efficient. In addition, for HB-LED lighting applications, an ac-dc LED driver demands high-step-down conversion ratio, less source current harmonics, high power factor (PF) and to be cost effective. This work proposes a high-step-down coupled inductor-buck (HSD-CIB) based power factor correction (PFC) converter operating in discontinuous current mode (DCM) to attain high PF with low source current harmonics. Moreover, the proposed HSD-CIB can overcome the demerit of the existing single-stage ac-dc buck PFC converter in terms of highvoltage/current switching stress, gate-driver complexity, low conversion gain and low efficiency. This paper presents the detailed design and analysis of the proposed HSD-CIB PFC converter for an LED lighting system. A closed loop voltage mode control (VMC) is designed and implemented to study the line regulations of HSD-CIB converter at various loading conditions. The analysis of the proposed HSD-CIB topology is carried out using Matlab/Simulink simulation and validated experimentally with a prototype of 16 W.
PL
W artykule zaprezentowano korzyści wynikające z zastosowania układów ultraszybkiej kompensacji mocy biernej. Układ ultraszybkiej kompensacji to system poprawy jakości energii w czasie rzeczywistym, który zapewnia: poprawę współczynnika mocy, oszczędność energii, kontrolę i kondycjonowanie napięcia poprzez: redukcję migotania, redukcję przepięć i skoków prądu, filtrację harmonicznych oraz dużo więcej zastosowań dla różnych obciążeń dynamicznych. Urządzenie realizujące ultraszybką kompensację to Equalizer.
EN
The article presents the benefits resulting from the use of ultra-fast passive reactive power compensation systems. The ultra-fast compensation system is a real-time power quality improvement system that provides: power factor improvement, energy saving, control and conditioning of the voltage by: reduction of flicker, reduction of overvoltage and jumps of current, harmonic filtration and many more applications for different dynamic loads. The device that performs ultra-fast compensation is the Equalizer.
PL
W artykule przedstawiono zagadnienia związane z kompensacją mocy biernej w układach zasilających, w których występuje znaczna asymetria wartości prądu obciążenia w poszczególnych fazach.
EN
The analysis of the compensation system work is presented on the basis of measurement tests carried out in the selected industrial facility, depending on the location of measure of the current controlling the reactive power regulator.
PL
W referacie zaprezentowano metodę do pomiaru wartości kąta przesunięcia fazowego pomiędzy sygnałami prądu i napięcia przemiennego z odniesieniem wyniku pomiaru do państwowego wzorca jednostki miary kąta płaskiego, z wykorzystaniem enkodera inkrementalnego. Opracowana metoda pomiarowa ma zastosowanie do pomiaru wartości kątów przesunięć fazowych pomiędzy sygnałami o znacznej amplitudzie i znacznej różnicy wartości tych amplitud. Spójność pomiarowa pomiaru kątów między sygnałami elektrycznymi jest najczęściej odnoszona do Państwowego wzorca jednostek miar czasu i częstotliwości. W przypadku pomiarów kąta między sygnałami prądu i napięcia w elektroenergetyce zapewnienie spójności pomiarowej do wzorca czasu i częstotliwości jest bardzo kłopotliwe ze względu na duże wartości amplitud mierzonych sygnałów oraz na występujące duże różnice wartości amplitud.
EN
The paper presents a method for measuring the value of the phase angle between current and alternating current signals with reference to the national standard of the angle of flat unit, using an incremental encoder. The developed measurement method is used to measure the values of the phase shift angles between high amplitude signals and a significant difference in the values of these amplitudes. The traceability for the measurement phase of angle between electrical signals is most often referred to the national time and frequency standard. In the case of measuring angles between current and voltage signals in the power supply, it is very troublesome to ensure the consistency of the measurement with the time and frequency standard because of the large amplitude values of the measured signals and differences amplitude.
PL
Właściwa gospodarka mocą bierną w systemach elektroenergetycznych to dziś bardzo popularne zagadnienie. Dzięki odpowiedniej kompensacji mocy biernej uzyskuje się bowiem poprawę współczynnika mocy a także pozytywnie wpływa się na jakość energii elektrycznej. Poprawa współczynnika mocy oraz jakości energii elektrycznej to dwa podstawowe cele wykonywania kompensacji.
PL
W artykule przedstawiono podstawowe zagadnienia związane z kompensacją mocy biernej w układach elektrycznych. W pierwszej części opisano odbiorniki mocy biernej.
EN
This article presents the basic issues of reactive power compensation in electrical systems. The first part describes receivers of passive power.
EN
The article presents the laboratory research of a prototype device for grinding and mixing materials, known as an electromagnetic mill. Studies were made of the circuit of the mill inductor, covering the analysis of the current intensity, magnetic induction and power factor during operation. The article further shows the laboratory stand and research equipment used during the measurements.
PL
W dyskusjach nad właściwościami energetycznymi obwodów elektrycznych z uporem powraca pogląd, że straty energii przy jej przesyle ze źródła zasilania do odbiornika powodowane są oscylacjami tej energii. Dużą rolą w utrwalaniu tego poglądu ma norma DIN 40100, która wprowadziła koncepcję rozkładu mocy chwilowej p(t) na moc chwilową wejściową pv(t) (dodatnią) oraz moc chwilową powrotną pr(t) (ujemną). Niniejszy artykuł pokazuje, że nie ma wyraźnego związku między współczynnikiem mocy obwodu oraz stratami energii przy jej przesyle a mocą wejściową pv(t) oraz mocą powrotną pr(t). W artykule pokazano również, że oscylacje energii między źródłem zasilania a odbiornikiem nie mają wpływu na współczynnik mocy odbiornika, oraz wykazano, że nie ma w obwodach elektrycznych żadnego zjawiska fizycznego, które wymagałoby wprowadzenia do jego opisu pojęcia mocy biernej Q, co oznacza, że moc bierna Q nie jest wielkością fizyczną.
EN
In discussions on power properties of electrical circuits recurrent point of view is expressed that the energy loss is caused by the energy oscillation. The spread of this opinion is instigated by Standard DIN 40100, which introduced the concept of the instantaneous power pv(t) decomposition on an input instantaneous power pv(t) (positive) and a returning instantaneous power pr(t) (negative). The paper demonstrates that there is no clear relation between the power factor and the energy loss at its delivery on the input and the returning instantaneous powers pv(t) and pr(t). Moreover, it is shown in the paper that the energy oscillation between the supply source and the load has no effects on the power factor. It was shown as well that there is no physical phenomenon in electrical circuits that requires the concept of the reactive power, which means that the reactive power is not a physical quantity.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.