Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  współczynnik efektywności
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper deals with the active reduction of beam vibrations using piezoelectric transducers (PZT). The LQR parameters of the control of an asymmetric actuator (a-PZT) depending on the length of its arms were analysed. The results were compared to those of the symmetrical PZT (s-PZT), so far used as standard. The actuator is modeled with two bending moments or two pairs of forces. The design of the LQR controller also took into account the location of the PZT on the beam. The reduction efficiency can also be increased by using asymmetrical PZT. To obtain the vibration asymmetry of the beam, simply supported at both ends, an asymmetrically point mass was added. The LQR control was applied to an asymmetric actuator on the beam. Two-parameter optimization was used to find the optimal proportions of the a-PZT arms. For such a problem, the LQR control parameters were found, which ensure the highest efficiency of vibration reduction.
EN
Purpose: The aim of studies undertaken in the article is to identify factors that may have an effect on the relationship between the results of interim management projects and increasing their effectiveness. Design/methodology/approach: An empirical-inductive approach – the literature studies and secondary empirical data analyses. Findings: The authors point to the following three key factors: trust, power and knowledge. In the future, the results of the studies presented here will form the foundations to develop an empirical-inductive research program with the aim to verify the significance of the identified factor, the relationships between them and their effect on the effectiveness of the process. It applies not only to commercial organizations, but also to non-profit institutions, political organizations and public utility organizations, such as health care institutions. Practical implications: This article refers to the effectiveness of the implementation process of interim management projects. The effectiveness of the whole process is strongly conditioned by both the competence of the interim manager and the perception of the client. Research results can be used to improve these competences and to improve the effectiveness of IM projects. Originality/value: The pioneering nature of work aimed at filling the existing research gap and answering the research question made the authors opt for an empirical-inductive approach.
PL
Przeprowadzono ocenę oporów dyfuzyjnych dla procesu rozkładu nadtlenku wodoru przez komercyjną katalazę Terminox Ultra immobilizowaną na powierzchni nieporowatych kulek szklanych. Oceny dokonano w oparciu o wcześniejszą analizę, na podstawie której określono model zewnętrznego transportu masy oraz wartości stałych szybkości reakcji (kR). Pokazano, że dla Q ≥ 15 cm3min-1 najwolniejszym etapem jest dyfuzja wewnątrz biokatalizatora, natomiast dla Q < 15 cm3min-1 transport masy w warstwie ciekłej otaczającej biokatalizator. Przeprowadzona ocena w pełni uzasadnia zastosowanie globalnego współczynnika efektywności jako wielkości wyrażającej wpływ oporów dyfuzyjnych.
EN
Evaluation of diffusive resistance for hydrogen peroxide decomposition by Terminox Ultra catalase immobilized on the surface of nonporous glass beads was carried out. The evaluation was made on basis of earlier analysis in which the external mass transfer model was developed with the intrinsic constant rate for reaction and deactivation. It was shown that the slowest step is the internal diffusive resistance inside the biocatalyst forQ ≥ 15 cm3min-1 and the external diffusive resistance in the liquid layer surrounding the biocatalyst for Q < 15 cm3min-1'. The conducted analysis justifies the introduction of global effectiveness factor expressing the effect of diffusive resistance.
PL
W artykule przedstawiono efektywność instalacji ze sprężarkową pompą ciepła z poziomym kolektorem gruntowym, znajdującym się na głębokości 110 cm pod powierzchnią terenu. Po przeprowadzeniu badań na stanowisku badawczym, w latach 2007 ÷ 2013 dla 6-ciu sezonów grzewczych, wyznaczono średnie wartości współczynników efektywności (COPINS) dla poszczególnych miesięcy pracującej instalacji z pompą ciepła i całego okresu eksploatacji. Przedstawiono także koszty związane z wydatkami poniesionymi na ogrzewanie budynku przy wykorzystaniu pompy ciepła. Z przeprowadzonej analizy wynika, że zastosowanie kolektora poziomego w zestawieniu z pompą ciepła i systemem grzejników konwektorowych, to także efektywne rozwiązanie pozwalające na osiąganie wysokich współczynników COP dla całej instalacji.
EN
The article presents the efficiency of an installation with a compressor heat pump with a horizontal ground collector, located at the depth of 110 cm below the area surface. After tests were conducted at the testing stand, in the period 2007 ÷ 2013 for six heating periods, mean values of efficiency coefficients (COPINS) were determined for particular months of an operating installation with a heat pump and the whole operation period. Besides, the costs connected with expenses incurred to heat the building when using the heat pump were presented. The conducted analysis shows that the application of a horizontal collector together with a heat pump and a system of convector heaters is also an effective solution allowing reaching high COP coefficients for the whole installation.
PL
W prezentowanej pracy przedstawiono wyniki analizy procesu ogrzewania budynku przy współpracy pompy ciepła z wodnymi akumulatorami ciepła izolowanymi termicznie od otoczenia, które stanowiły dolne źródła ciepła dla pompy. Rozważono kilka wodnych akumulatorów ciepła. W pierwszym etapie rozważań akumulatory w kształcie sześcianu różniły się objętością wody (pojemnością cieplną) i współczynnikami przenikania ciepła przez ich ściany, ale każdy z nich zapewniał ilość ciepła potrzebną do ogrzania budynku. Natomiast w następnej części, rozważono wodne akumulatory ciepła o takim samym współczynniku przenikania ciepła przez ściany, ale różniące się pojemnością cieplną. Akumulator przejmował ciepło od absorberów słonecznych i gromadził to ciepło w okresie letnim. Przeprowadzona analiza wykazała, że w przypadku akumulatorów o dużej pojemności budynek może być ogrzewany w ciągu całego sezonu grzewczego bez udziału pompy ciepła, jedynie przy wykorzystaniu pompy obiegowej transportującej ciepło z akumulatora do ogrzewanego obiektu. Natomiast w przypadku akumulatorów o mniejszej pojemności jedynie w części sezonu grzewczego budynek może być ogrzewany w oparciu o wymianę ciepła pomiędzy akumulatorem a ogrzewanym budynkiem bez udziału pompy ciepła. W dalszej części sezonu grzewczego, gdy temperatura wody w akumulatorze obniży się, do ogrzewania włączona zostanie pompa ciepła dla której ten akumulator wodny byłby dolnym źródłem ciepła. Pozwoliłoby to osiągnąć bardzo wysoką średnioroczną wartość współczynnika wydajności pomp ciepła (COP).
EN
The paper presents the results of the building heating process analysis, in cooperation of a heat pump with water thermally insulated from the environment heat accumulators, which were lower heat source for the pump. Several water heat accumulators were considered. In the first stage, the cube-shaped batteries differed in the volume of water (heat capacity) and the heat transfer coefficients of the wall, but each of them provided the quantity of heat needed to heat the building. However, in the next section, water heat accumulators of the same heat transfer coefficient of the wall were considered, but with a different heat capacity. The battery took the heat from solar absorbers and collected it in the summer. The analysis showed that in the case of high-capacity batteries a building can be heated during the whole heating season without the heat pump, only by using the heat pump of the accumulator conveyor to the heated object. However, in the case of smaller capacity batteries with only part of the heating season, the building can be heated without the heat pump. In the remainder of the heating season, when the water temperature in the battery becomes low, the heat pump, for which the battery water would lower the heat source, will be activated. This would allow to achieve a very high average annual value of the heat pump performance coefficient (COP).
6
Content available remote Estimation of Apollo Lunar Dust Transport using Optical Extinction Measurements
EN
A technique to estimate mass erosion rate of surface soil during landing of the Apollo Lunar Module (LM) and total mass ejected due to the rocket plume interaction is proposed and tested. The erosion rate is proportional to the product of the second moment of the lofted particle size distribution N(D), and third moment of the normalized soil size distribution S(D), divided by the integral of S(D)⋅D2/v(D), where D is particle diameter and v(D) is the vertical component of particle velocity. The second moment of N(D) is estimated by optical extinction analysis of the Apollo cockpit video. Because of the similarity between mass erosion rate of soil as measured by optical extinction and rainfall rate as measured by radar reflectivity, traditional NWS radar/rainfall correlation methodology can be applied to the lunar soil case where various S(D) models are assumed corresponding to specific lunar sites.
PL
W artykule przedstawiono rozwiązania dotyczące poprawy i wzrostu efektywności zarządzania działalności studentów na zajęciach z użyciem narzędzi internetowych. Za pomocą tych rozwiązań studenci mogą mieć zawsze i wszędzie swobodny dostęp w informacji, takich jak: kursy, wirtualne materiały laboratoryjne, opisy badań oraz statystyki. Następnie przedstawiono wybrane wyniki badań i przykłady platform e-learningowych stosowanych w Rumunii. W eksperymencie naukowym zastosowano techniki grup równoległych (4 grupy studentów drugiego roku, 2 grupy tworzące zespół eksperymentalny, dla których były używane kursy multimedialne do procesu szkolenia, i 2 grupy kontrolne). Przeprowadzone badania potwierdziły hipotezę o pozytywnym wpływie realizacji kursów multimedialnych w procesie nauczania grup eksperymentalnych i efektywności stosowanych metod.
EN
In this article, we presented a solution for improving and rising the management efficiency of the students’ activities for the courses in the current semester, using Web Technologies. Moreover, using this solution given by the described application, students of any faculty can have anytime and anywhere access to information such as: courses materials, virtual labs materials, marks given for partial or final tests, statistics regarding the scholar situations. Then, we presented some statistics and examples of e-learning platforms realized in Romania. In this scientific experiment we applied the technique of parallel groups which supposes the implication of 4 groups of second year students, 2 groups forming the experimental team for whom the multimedia courses for training process were used and 2 control groups for whom teaching was made in the traditional system. The application of the statistical methods of processing experimental data attested the hypotheses about the positive impact of the implementation of the multimedia courses in teaching- learning process in the experimental groups and the efficiency of the applied methods to the experimental groups, compared to traditional methods, applied to control groups.
PL
Przedstawiono urządzenie i sposób do zwiększenia wydajności dolnego źródła pompy ciepła. Na podstawie przeprowadzonych badań na stanowisku badawczym w latach 2009-2010 obliczono współczynnik efektywności (COP i COPINS) dla poszczególnych miesięcy pracującej instalacji i pompy ciepła. Z przeprowadzonej analizy wynika, że wykorzystanie dodatkowego ciepła niskotemperaturowego, pozyskanego z wody wodociągowej (ujęcia głębinowe), może w znacznym stopniu wpłynąć na zwiększenie efektywności pracy pompy ciepła i zmniejszenie kosztów ogrzewania budynku.
EN
The paper presents a device and method to increase efficiency heat source heat pumps. Based on the survey on the bench in the years 2009/2010 calculated the coefficient of performance (COP and COPINS) for each month working installations and heat pumps. The analysis shows that the use of additional low-temperature heat, derived from tap water (deep-water intake), could have a significant impact on increasing the efficiency of heat pump and reduce the cost of heating the building.
PL
W artykule zawarto opisy rozwiązań i eksploatacji wodnych pomp ciepła. Ukazano wady i zalety poszczególnych rozwiązań, w tym również zagrożenia tworzenia się na powierzchni wymienników ciepła lodu. Przedstawiono problemy eksploatacyjne systemów w zależności od jakości wody zasilającej. Analizy literaturowe i badania własne pozwalają na ocenę wpływu temperatury oraz natężenia przepływu wody na efektywność COP.
EN
An overview of solution of water source he at pumps are presented in this paper. The advantages and disadvantages of different options including the creation of hazards on the surface of he at exchangers ice are showed to. The problems of operating systems, depending on the quality of water supply . Analysis of literature and own studies allow an assessment of the impact of temperature and flow rate of water on the effectiveness of the COP
first rewind previous Strona / 1 next fast forward last