Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  wskaźnik naprężenia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: Previous biomechanical studies have estimated the strains of bone and bone substitutes using strain gages. However, applying strain gages to biological samples can be difficult, and data collection is limited to a small area under the strain gage. The purpose of this study was to compare digital image correlation (DIC) strain measurements to those obtained from strain gages in order to assess the applicability of DIC technology to common biomechanical testing scenarios. Methods: Compression and bending tests were conducted on aluminum alloy, polyurethane foam, and laminated polyurethane foam specimens. Simplified single-legged stance loads were applied to composite and cadaveric femurs. Results Results: Showed no significant differences in principal strain values (or variances) between strain gage and DIC measurements on the aluminum alloy and laminated polyurethane foam specimens. There were significant differences between the principal strain measurements of the non-laminated polyurethane foam specimens, but the deviation from theoretical results was similar for both measurement techniques. DIC and strain gage data matched well in 83.3% of all measurements in composite femur models and in 58.3% of data points in cadaveric specimens. Increased variation in cadaveric data was expected, and is associated with the well-documented variability of strain gage analysis on hard tissues as a function of bone temperature, hydration, gage protection, and other factors specific to cadaveric biomechanical testing. Conclusions: DIC techniques provide similar results to those obtained from strain gages across standard and anatomical specimens while providing the advantages of reduced specimen preparation time and full-field data analysis.
EN
To investigate the mechanical properties of tunnel lining concrete under different moderate-low strain rates after high temperatures, uniaxial compression tests in association with ultrasonic tests were performed. Test results show that the ultrasonic wave velocity and mass loss of concrete specimen begin to sharply drop after high temperatures of 600 °C and 400 °C, respectively, at the strain rates of 10-5s-1 to 10-2s-1. The compressive strength and elastic modulus of specimen increase with increasing strain rate after the same temperature, but it is difficult to obtain an evident change law of peak strain with increasing strain rate. The compressive strength of concrete specimen decreases first, and then increases, but decreases again in the temperatures ranging from room temperature to 800 °C at the strain rates -5s-1 to 10-2s-1. It can be observed that the strain-rate sensitivity of compressive strength of specimen increases with increasing temperature. In addition, the peak strain also increases but the elastic modulus decreases substantially with increasing temperature under the same strain rate.
PL
Odporność ogniowa to jedno z najistotniejszych zagadnień, jakie należy brać pod uwagę przy projektowaniu tunelu. Testowanie właściwości mechanicznych betonu po pożarze stało się, jak dotąd, przedmiotem wielu projektów badawczych. Jakkolwiek powstały liczne publikacje na temat właściwości mechanicznych betonu w trakcie oraz po poddaniu go działaniu wysokich temperatur, niewiele uwagi poświęcono jak dotąd dynamicznym właściwościom mechanicznym betonu w trakcie lub po takim oddziaływaniu. W przypadku wielu konstrukcji betonowych takich, jak tunele czy budynki, oczekuje się, że po pożarze będą one nadal pełniły swoją funkcję. Konstrukcje te mogą być też narażone na obciążenia sejsmiczne w trakcie okresu użytkowania. Dlatego też konieczne jest studiowanie dynamicznych właściwości mechanicznych betonu w trakcie lub po ekspozycji na działanie wysokich temperatur. Aby przeanalizować właściwości mechaniczne betonowych okładzin tunelowych w stanie zróżnicowanego naprężenia od umiarkowanego do niskiego po oddziaływaniu wysokich temperatur, przeprowadzono testy naprężenia jednoosiowego w połączeniu z badaniami ultradźwiękowymi. Klasa wytrzymałości betonu na ściskanie w przypadku wykorzystanych próbek to C40. Próbki poddawano oddziaływaniu szczytowych temperatur, wynoszących 200, 400, 600 i 800 °C. W ramach testów naprężenia jednoosiowego zastosowano cztery wskaźniki naprężenia, tj.: 10-2s-1, 10-3s-1, 10-4s-1. oraz 10-5s-1.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.