Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  woltamperometria inwersyjna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Natrolite - a natural zeolite - has been proposed as an adsorbent for preconcentration of traces of cadmium. Cadmium ions from different samples were adsorbed on Natrolite column packing in the presence of 2-{5-bromo-2-pyridylazo)-5-diethylarninophenol reagent in the pH range of 7.0—10.5. Subsequently, cadmium was eluted from the column with 10.0 mL of 2 mol L-1 HCl and determined by highly selective, sensitive, fast and economical anodic stripping differential pulse voltammctric method. Detection limit was 0.4 ppb. The obtained calibration plot was linear in cadmium concentration range in the final solution: 1.0-2.1 x 105 pp b, r = 0.9992. RSD = ± 0.75% for eight replicate determinations of l ppm cadmium. By applying the proposed method, 4 ng of cadmium could be concentrated from 400 mL of the aqueous sample (concentration 0.01 ppb). Various parameters influencing determination of cadmium, e.g. pH, flow rate, instrumental conditions, and the presence of foreign ions were investigated in order to optimise conditions of the analysis. The proposed method was successfully applied to the determination of cadmium in various complex samples.
PL
Zaproponowano użycie Natrolitu - naturalnego zeolitu, jako adsorbentu do zateżania jonów kadmowych. Jony kadmu z różnych próbek adsorbowano na kolumnie wypełnionej Natrolitem obsadzonym 2-(-5-bromo-2-pirydy!azo)-5-dietyloaminofenolem w zakresie pH 7.0-10.5. Kadm wymywano v. kolumny 10-cioma mL 2 mol L-1 HCL i oznaczano za pomocą wysoko selektywnej, czułej, szybkiej i oszczędnej metody, jakąjest anodowa różnicowa woltamperometria inwersyjna. Granica wykrywalności wynosiła 0.4 ppb. Uzyskany wykres kalibracyjny był liniowy w zakresie stężeń kadmu w końcowym roztworze: 1.0-2.1 x 105! ppb, r = 0,9992, RSD = ± 0,75% (wyznac/onc na podstawie 8-u oznaczeńroztworu zawierającego 0-01 ppb kadmu). W celu zoptymalizowania warunków analizy zbadano szereg parametrów mających wpiyw na oznaczanie kadmu, takich jak: pH. szybkość przepływu, warunki instrumentalne i obecność jonów obcych. Opracowaną metodę zastosowano do oznaczania kadmu w rozmaitych próbkach rzeczywistych.
EN
Our investigations were concerned with the determination of four heavy metals in six sampling sites from 1996 to 1999. These places are situated - from one side - in the open sea, where most of recreation towns are situated and - on the other side - in the area of the Gdansk Bay, where the industry is located. Anodic stripping voltammetry (ASV) was used for the determination of selected toxic metals (Pb, Cd, Zn, Cu) in natural water samples. The monitored metals were found to be present in selected sampling sites. This can indicate the contamination of the Gdańsk Bay originates from quite different sources. The flood in Poland (1997) has not caused any increase of the contamination of the Gdańsk Bay and Vistula River with toxic heavy metals.
PL
Badania dotyczyły oznaczania czterech metali ciężkich w sześciu punktach pomiarowych od 1996 do 1999 r. Miejsca pobierania próbek znajdowały się, z jednej strony, na otwartym morzu, gdzie zlokalizowana jest większość miast turystycznych, z drugiej strony, w rejonie Zatoki Gdańskiej, gdzie zlokalizowane są zakłady przemysłowe. Do oznaczania wybranych metali ciężkich (Pb, Cd, Zn, Cu) w wodach naturalnych zastosowano woltamperometrię inwersyjną (ASV). Oznaczane metale zostały znalezione we wszystkich punktach pobierania próbek. Świadczy to o tym, że zanieczyszczenia Zatoki Gdańskiej pochodzą z różnych źródeł. Powódź w Polsce w 1997 r. nie spowodowała wzrostu zanieczyszczenia Zatoki Gdańskiej i Wisły metalami ciężkimi.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.