The article presents the results of the evaluation of application for funding the geothermal projects submitted in the first call for proposals under the priority program “Accessing thermal waters in Poland”. The article also describes the current stage of geothermal projects financed from the fund in previous years and the key assumptions of the government regarding the development of knowledge about geothermal conditions in Poland.
EN
Recognition of the hydrogeological conditions of deep aquifers is possible mainly due to research carried out in deep boreholes. Such boreholes have been drilled in Poland since the 1950s. These are mainly exploration wells for hydrocarbon deposits, including research wells. Due to the purpose of these drillings, hydrodynamic and hydrochemical tests of aquifers with thermal waters are rare and carried out to a limited extent. Since 2010, there has been a clear increase in interest in the use of thermal waters in Poland. Due to the hydrogeological and geothermal conditions, the resources of these waters are made available in Poland through deep boreholes. The number of new geothermal wells has doubled in the last decade. Hydrodynamic tests (pumping, and hydrodynamic tests) and hydrochemical tests (analyses of physical and chemical properties of water, tests of the isotopic composition of water) carried out in these boreholes enable detailed characterization of the hydrogeological conditions prevailing in deep aquifers. They allow for the characterization of the pressure conditions in aquifers, the determination of the direction and velocity of groundwater flow, the duration of water in the rock massif, determination of the origin of water and presumed supply areas, as well as the hydrogeochemical characteristics of the waters. Therefore, the use of geothermal resources significantly contributes to the identification of the hydrogeological conditions of deep aquifers.
EN
The paper presents results of evaluation of geothermal projects submitted in 2016-2018 within the priority program entitled Geology and mining, part 1 - "Understanding the geological structure of the country and the management of mineral and groundwater resources” implemented from the financial resources of the National Fund for Environmental Protection and Water Management. The paper also describes the present-day stage of geothermal projects financed by the fund and the assumptions of a new priority program that is currently being implemented in order to develop geothermal heating in Poland.
PL
Przeprowadzono analizę energetyczną dotyczącą absorpcyjnej pompy ciepła wykorzystującej lokalne zasoby wody termalnej o temperaturze ok. 60°C na potrzeby konwencjonalnego miejskiego systemu ciepłowniczego (130°C/90°C). Wykazano, że w zależności od współczynnika efektywności pompy ciepła wynoszącego 1,4-1,8, pobrany zasób energii geotermalnej stanowi ułamek wynoszący odpowiednio ok. 0,33-0,67 nakładu pierwotnej energii napędowej niezbędnej do pracy pompy ciepła.
EN
There was conducted an energetic analysis of an absorption heat pump that uses local thermal water's resources of temperature about 60°C for the needs of a conventional district heating system (130°C/90°C). It was demonstrated that depending on the heat pump’s effectiveness factor (1,4-1,8), retrieved stock of geothermal energy makes up a fraction of about 0,33-0,67 of expenditions of the primary driving energy necesssary for the pump to work.
EN
On Spitsbergen there are four areas of occurrence of thermal spring waters. The studies of these waters have a long history dating back to the nineteenth century. Outflows of thermal waters are associated with tectonic discontinuities, where subpermafrost waters can flow to the surface area. The maximum temperatures of discharged thermal water exceed 25°C. The chemical composition of thermal waters from northern Spitsbergen derived from relict sea water, which is then modified by rainwaters, waters of melting permafrost and contemporary sea waters. On the other hand, on the southern Spitsbergen thermal waters are characterized by a lower mineralization and there are contemporary waters involved in the deep circulation. Thermal waters with low mineralization are mainly multi-ions with dominate type bicarbonate-chloride-sodium-calcium. Thermo-mineral waters belong mainly to the types of chloride-sodium and chloride-bicarbonate-sodium.
EN
Geochemical studies on trace elements in thermal waters from Cieplice, Karpniki and Staniszów (Jelenia Góra Geothermal System, Sudetes, Poland) revealed a presumably regional relation between germanium and silicon. The Ge:Si ratios in waters of Cieplice are likely controlled by the chemical equilibrium process of silicate minerals transformation in granite aquifer-rocks. Geochemical inverse mass balance modelling using main rock-forming minerals of actual composition shows that incongruent dissolution ofprimary silicate minerals with forming secondary (clay minerals, silica forms) phases is responsible for thermal water chemistry in Cieplice. Available data on germanium in silicate minerals combined with the results of geochemical modelling give Ge:Si ratios close to real values. A chemical non-equilibrium, and a gradual decrease of both the germanium content and the Ge:Si ratio have been identified in the thermal waters from two new intakes (Karpniki, Staniszów).
PL
W pracy przedstawiono wyniki badań geologicznych, geofizycznych, laboratoryjnych oraz hydrogeologicznych przeprowadzonych w rejonie miejscowości Celejów. Badania przeprowadzono dwoma otworami wiertniczymi: Celejów GT-1 i Celejów GT-2. Otwór Celejów GT-1 został wykonany do głębokości 3504 m i zakończony w utworach dewonu. W otworze tym nie uzyskano przypływu wody złożowej, natomiast na dnie otworu temperatura osiąga wartość 99,8°C. Otwór Celejów GT-2 został wykonany do głębokości 1234 m i zakończony w utworach jury środkowej. W otworze tym uzyskano wypływ wody termalnej w ilości 28 m3/h, temperaturze na wypływie wynoszącej 29,2°C (31°C w złożu) oraz mineralizacji ogólnej równej 45,5 g/dm3.
EN
The paper presents the results of geological, geophysical and hydrogeological studies in the area of Celejów. The study was conducted on two wells – Celejów GT-1 and Celejów GT-2. The Celejów GT-1 well has a depth of 3,504 meters and was completed on the Devonian layer. In this well, the flow of water reservoir was not obtained, while the well’s bottom temperature is around 99.8°C. The Celejów GT-2 well has a depth of 1,234 meters and was completed on the middle Jurassic layer. In this well, the flow of thermal water of 28 m3/h was obtained, the temperature of 29.2°C (31°C in the layer) and total mineralization equal to 45.5 g/dm3was recorded.
EN
The Warsaw region has opportunity to utilise geothermal energy for heating and recreation. Lower Cretaceous and Lower Jurassic aquifers are the most prospective for the utilisation of this renewable energy. The heat flow value is low in this region and does not exceed 60 mW/m2. The hydrogeological factor of exploitation wells is the permeability of the aquifers and possibility of thermal water flow. The active porosity at a depth of 3000 m is too low for groundwater abstraction. Investments in geothermal installations are not profitable and are not supported by local communities. Thus, the investment in geothermal installation bears a significant economic risk. Expected Monetary Value ( EMV) is the proposed method for evaluation of profitable expected economic effect. The hazards of economic loses or yield of profit are the basis for the decision makers.
PL
W pracy przeanalizowano możliwości zagospodarowania zasobów geotermalnych głównie pary wodnej i wody termalnej. Skupiono sie głównie nad wykorzystaniem geotermii do produkcji energii elektrycznej i ciepła. Dokonano również analizy możliwych wariantów zagospodarowania wody termalnej rozpoznanej na Niżu Polskim z pomocą wykonanych po 2008 roku otworów geotermalnych. Do oceny przydatności możliwej do pozyskania nowych zasobów geotermalnych na Niżu Polskim dokonano porównania ich temperatury i wydajności z parametrami zasobów już eksploatowanych. W wyniku przeprowadzonej analizy stwierdzono, że na Niżu Polskim odkryte nowe zasoby wód termalnych mogą być wykorzystywane w ciepłownictwie oraz w balneoterapii i rekreacji.
EN
The paper presents the analyses of possibilities of managing the geothermal resources, mainly water vapour and thermal water. The analyses are focused on the possibilities of using geothermal energy to produce electricity and heat. The geothermal wells made after 2008 was used to help to diagnose the utilization of thermal water located on Polish Lowlands. To assess the suitability of new geothermal resources that could be possible to access on Polish Lowlands, the comparison of temperature and efficiency of the new and already used geothermal resources was conducted. Based on the results it was stated that new geothermal resources located on Polish Lowlands can be used for heating, balneotherapy and recreation.
PL
Głównym problemem z eksploatacją ciepłowni geotermalnych jest zatykanie się geotermalnych otworów chłonnych. Otwory te zatykane są osadami powstającymi w wyniku schładzania wód termalnych. Rezultatem wieloletnich prac związanych z czyszczeniem otworów chłonnych było opracowanie metody super miękkiego kwasowania. Metoda ta jest obecnie w fazie wdrożenia na instalacji geotermalnej w Pyrzycach. Jej zastosowanie pozwoliło na ustabilizowanie pracy ciepłowni geotermalnej, zwiększenie wykorzystania odnawialnego źródła energii oraz obniżenie emisji CO2.
EN
The main problem occurring during the operation of the geothermal plants is clogging of the geothermal absorbent wells. These wells are plugged with the sludge produced during the process of thermal water cooling. As the result of many years of work related to the cleaning of the absorbent wells, the method of super soft acidizing was developed. This method is currently in the implementation phase of the installation of geothermal plant in Pyrzyce. The use of super soft acidizing method allows to stabilize the work of geothermal heat plant, increasing the use of renewable energy sources and reducing CO2 emissions.
PL
Efektywność pracy ciepłowni geotermalnej zależy głównie od ilości możliwej do zatłoczenia, schłodzonej wody termalnej. Na początku działalności ciepłowni geotermalnej w Pyrzycach wodę termalną można było eksploatować z wydajnością 340 m3/h. Obecnie woda termalna eksploatowana jest z wydajnością około 100 m3/h. Bardzo poważnym problemem niemal wszystkich ciepłowni geotermalnych jest kolmatacja strefy przyodwiertowej związkami chemicznymi wytrącającymi się ze schłodzonej wody termalnej. Osady powstają w wyniku zmian warunków fizyko-chemicznych spowodowanych eksploatacją. Wydaje się, że tego procesu obecnie nie da się całkowicie wyeliminować przy zatłaczaniu wód do kolektorów porowych. Drugim poważnym problemem występującym w ciepłowniach geotermalnych jest postępująca korozja rur okładzinowych. Na podstawie wykonanych pomiarów geofizycznych zjawisko korozji obserwuje się głównie w otworach chłonnych i w napowierzchniowych rurociągach tłocznych. Obecnie istnieje teoretyczna możliwość wyeliminowania albo przynajmniej bardzo poważnego zmarginalizowania wpływu korozji na kolmatację strefy złożowej w otworach chłonnych przez zastosowanie rur z tworzywa sztucznego wzmocnionego włóknem szklanym lub rur wyłożonych od środka wykładziną polietylenową typu HDPE (High Density PoliEtylen).
EN
The efficiency of geothermal heat plant depends mainly on the amount of cold thermal water which is possible for congestion. At the beginning of activities of the geothermal plant in Pyrzyce, the thermal water could be exploited with efficiency of 340 m3/h. Currently thermal water is operated with efficiency of approximately 100 m3/h. The process of the hole’s clogging with chemical compounds is a serious problem for almost all geothermal plants. These sediments are the result of changes in physico-chemical conditions caused by the water exploitation. It seems that currently the process can not be completely eliminated during the process of pumping the water to collectors. The second major problem occurring in geothermal heating plants, is progressive corrosion of lining tubes. Based on the geophysical measurements, it can be stated that corrosion is observed mainly in the absorbent hole and pipelines. Currently, there is a theoretical possibility of eliminating, or at least marginalizing, the impact of corrosion on layers’ clogging in absorbent hole by using the pipes made of plastic with addition of fiber glass or pipes covered from inside with polyethylene HDPE (High Density Polyethylene).
PL
W artykule przedstawiono doświadczenia zdobyte z eksploatacji ciepłowni geotermalnych działających na terenie Niżu Polskim. Na podstawie tych doświadczeń, mogą być oceniana warunki techniczne, które powinny być brane pod uwagę podczas budowy nowych ciepłowni geotermalnych. Przeprowadzone obserwacje dotyczą głównie technologii wykonywania odwiertów, materiałów użytych do ich budowy, materiałów używanych do budowy rurociągów i urządzeń geotermalnych wykorzystywanych w procesie odbioru ciepła.
EN
The article presents the experience gained from the exploitation of geothermal plants operating on Polish Lowland. Based on this experience, the technical conditions, that should be taken into account during the construction of new geothermal plants, can be assessed. The observation concerns the technologies of performing the wells, the materials used for their construction, materials used for construction of pipe-lines and the geothermal devices used in the process.
PL
W pracy przedstawiono przegląd siłowni binarnych działających na świecie w warunkach zbliżonych do tych panujących na Niżu Polskim. Skupiono się głównie na tych w których wykorzystywana jest woda termalna o temperaturze około 100oC. Przeanalizowano również parametry wody termalnej możliwej do pozyskania na Niżu Polskim za pomocą już wykonanych otworów geotermalnych, w których wykonywane były pompowania pomiarowe.
EN
This paper presents an overview of the binary power plants operating all over the world in the conditions similar to those prevailing on Polish Lowlands. The paper is focused mainly on those power plants in which the thermal water's temperature is around 100oC. The parameters of the thermal water possible to raise on Polish Lowlands are also analyzed by using already completed geothermal wells, in which the pumping test were performed.
PL
W pracy przeprowadzono analizę nowych możliwości pozyskiwania wody termalnej i energii geotermalnej na Niżu Polskim, gdzie od 2008 roku powstało osiem nowych otworów badawczo-eksploatacyjnych. Otwory te obecnie mogą stanowić podstawę do budowy nowych ciepłowni geotermalnych wykorzystujących ciepło wnętrza Ziemi. Kilka nowych otworów może stanowić samodzielne źródło ciepła dla niskotemperaturowych systemów grzewczych. Aby uzyskać maksymalne schłodzenie wody termalnej we wszystkich przypadkach zaproponowano zastosowanie absorpcyjnej pompy ciepła. Woda wydobywana za pomocą dwóch nowych otworów będzie mogła być wykorzystywana głównie do celów balneoterapeutycznych i rekreacyjnych oraz będzie mogła stanowić dolne źródło ciepła dla sprężarkowych pomp ciepła.
EN
The paper analyzes the possibility of obtaining a new thermal water and geothermal energy in the Polish Lowlands, where since 2008, the eight new operational wells were drilled. These wells can now form the basis for the construction of the new geothermal plants using the heat from the earth inside. Several of them can be used as an independent source of heat for low temperature heating systems. In order to obtain a maximum cooling in all cases the use of an absorption heat pump was recommended. Water extracted from two of the new wells is designed mainly for recreation and therapy and as a heat source for the heat pump compressor.
PL
W pracy dokonano charakterystyki hydrochemicznej siarczkowych wód termalnych w otworze Busko C-1. Na podstawie wyników analiz fizyczno-chemicznych określono zmienność podstawowych parametrów. Badania dotyczyły przede wszystkim: temperatury, przewodności elektrolitycznej właściwej (PEW), zawartości w wodzie głównych jonów: chlorkowych, sodu oraz siarkowodoru. Siarczkowe wody termalne z otworu Busko C-1, związane są z utworami piaszczystymi cenomanu. Jest to woda mineralna typu Cl-Na, H2S, I.
EN
In this work shows hydrochemical characteristics of the thermal waters of sulphide in the borehole Busko C-1. Based on the results of physical and chemical analysis determined the variability of basic properties. The research concentrated mostly: temperature, specific electrolytical conductivity (SEC), water content of major ions: chlorine, sodium and hydrogen sulfide. Sulphurous thermal waters from Busko C-1 borehole are associated with Cenomanian formations. It is the mineral waters of type Cl-Na, H2S, I.
17
Content available remote Korozja stali konstrukcyjnej P5 w wodzie termalnej
PL
Przeprowadzono badania właściwości elektrochemicznych stopów Fe-5%Cr w 0,1 M Na2SO4 oraz w wodzie termalnej pochodzącej z odwiertu Bańska IG-1 (Geotermia Podhalańska S.A.). Celem tych badań było poznanie mechanizmu tworzenia warstewki produktów korozji odpowiedzialnych za stosunkowo dobrą odporność korozyjną stali/staliwa P5 w wodach termalnych o średniej mineralizacji i o temperaturze do 100oC. Przedstawiono mechanizm i kinetykę tworzenia anodowej warstewki produktów korozji na powierzchni stopu Fe-5%Cr oraz staliwa P5.
EN
Electrochemical behavior of Fe-5%Cr alloys has been investigated in aqueous solution of 0.1 M Na2SO4 and in thermal water from Bańska IG-1 well (Geotermia Podhalańska S.A.). The aim of the investigations was to explain the formation mechanism of surface corrosion product. The layer formed on the metal surface determines relative good corrosion resistance of P5 steel in thermal waters with medium salinity in temperature range up to 100oC. The mechanism and kinetics of the formation of the anodic surface fi lm, on the Fe-5%Cr alloy and on the cast steel P5 has been presented.
PL
W artykule przedstawiono przegląd konstrukcji otworów wiertniczych, które są zlokalizowane na Niżu Polskim. Przeanalizowano głównie konstrukcję tych otworów, które są wykorzystywane do eksploatacji wód termalnych w celu pozyskiwania ciepła z wnętrza ziemi. Na Niżu Polskim działają obecnie cztery ciepłownie geotermalne, a każda z nich charakteryzuje się inną konstrukcją otworów. W przygotowaniu są kolejne inwestycje geotermalne, gdzie zastosowano nowe konstrukcje otworów. W przypadku otworu eksploatacyjnego w Toruniu możliwe było przeprowadzenie prac badawczych dwóch poziomów wodonośnych i wybór tego o lepszych parametrach hydrogeologicznych. Nowe otwory chłonne wykonywane są z materiałów odpornych na korozyjne działanie eksploatowanej wody termalnej.
EN
In the article we present an overview of the construction of geothermal wells that are located on the Polish Lowlands. We analyzed mainly the construction of these wells, which are used to exploit the thermal water to raise the heat from the inside of earth. Currently on the Polish Lowland four geothermal heating plants are operating. Each of them has a different well's construction. The new geothermal investment, which are being prepared, are going to use quite new well's contractions. In the case of the geothermal well near Torun, it was possible to carry out the research on two aquifers and to choose the one with the better hydrogeological parameters. The new injection wells are made of materials resistant to corrosion of exploitation thermal water.
PL
W artykule zaprezentowana została koncepcja wykorzystania wody termalnej ujmowanej dubletem geotermalnym będącego częścią instalacji geotermalnej w powstającej Geotermii Kleszczów. Geotermia Kleszczów będzie szóstym uruchomionym na terenie Polski zakładem, który będzie wykorzystywał energię wód termalnych. W odróżnieniu od innych podobnych ciepłowni działających na terenie naszego kraju w Geotermii Kleszczów zdecydowano, że nośnikiem ciepła geotermalnego do jego odbiorców będzie woda termalna. Ciepło od wody termalnej będzie odbierane bezpośrednio u poszczególnych odbiorców, gdzie będą zamontowane geotermalne wymienniki ciepła, a schłodzona woda termalna będzie kierowana do otworu chłonnego.
EN
This article presents the concept of using thermal water extracted by the geothermal doublets which are the part of the geothermal plant in the emerging Geotermia Kleszczów. Unlike other similar heat plants operating in Poland it was decided in Geotermia Kleszczów that geothermal heat is going to be carried to its customers by thermal water. The heat from the thermal water is collected directly from individual customers, where the geothermal heat exchangers will be installed, and cooled thermal water will be directed to the injection well Kleszczów GT-2.
PL
W artykule zaprezentowano parametry pracy ciepłowni geotermalnej w Stargardzie Szczecińskim, gdzie po raz pierwszy w skali kraju dokonano zamiany roli otworów w dublecie geotermalnym. Po uruchomieniu ciepłowni woda termalna wydobywana była otworem eksploatacyjnym Stargard Szczeciński GT-1, a po schłodzeniu na wymiennikach ciepła była zatłaczana do tej samej warstwy wodonośnej za pomocą otworu chłonnego Stargard Szczeciński GT-2. W trakcie okołodwuletniego okresu eksploatacji następuje spadek wydajności oraz wzrasta ciśnienie zatłaczania. Zamiana roli otworów w dublecie geotermalnym w Stargardzie Szczecińskim pozwoliła na przeprowadzenie badań związanych z oceną możliwości stosowania analizowanego rozwiązania w innych ciepłowni ach geotermalnych. Wyniki prowadzonych badań wykazują, że po zmianie roli otworu chłonnego na eksploatacyjny uzyskano zwiększenie wydajności eksploatacji, ale zatłoczona wcześniej schłodzona woda termalna wychłodziła warstwę wodonośną
EN
The article presents the work parameters of the geothermal heating plant in Stargard Szczecinski, where for the first time in Poland the role of geothermal wells in the doubles were switched. At the very beginning of the heating plant activity, the thermal water was extracted by injection well named Stargard Szczecinski GT-1. After cooling on the heat exchangers, the water was injected into the same water-bearing stratum via the GT-2 injection well. During two years of activity the lost of productivity and the increase of pressure was observed. The conversion of the roles of geothermal wells in doubles in Stargard Szczecinski allowed to conduct research related to the possibility of applying this technical solution in other geothermal heating plants. The results of the study show that after changing the role of the injection well into the exploitation well the productivity was increased. The change has also the negative aspects as the injected earlier cool thermal water cooled the water-bearing stratum.