Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 25

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  wind generation
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote The analysis of the wind generation impact on the power system stability
EN
The article discusses the issues related to the influence of connecting wind turbines on the angular stability of the power system. Current plans for Poland's energy transition, climate issues, and the most popular types of wind turbines used in the world were discussed. In the study part, the impact of replacing traditional generating units with wind turbine systems connected by converters on the angular stability of the New England test model was analysed.
PL
W artykule zostały omówione zagadnienia dotyczące wpływu przyłączania turbin wiatrowych na stabilność kątową systemu. Omówiono aktualne plany dotyczące transformacji energetycznej Polski, kwestie klimatyczne, a także najpopularniejsze rodzaje turbin wiatrowych, wykorzystywanych na świecie. W części badawczej przeanalizowano wpływ zastępowania tradycyjnych jednostek wytwórczych układami turbin wiatrowych przyłączanych przez przekształtniki na stabilność kątową modelu testowego systemu New England.
PL
W artykule przedstawiono wyniki testów odbudowy zasilania obszaru sieci dystrybucyjnej z wykorzystaniem magazynu energii (ME) i rozproszonych źródeł odnawialnych. Próba pracy wyspowej z odnawialnymi źródłami energii (OZE) została wykonana na ograniczonym obszarze sieci elektroenergetycznej (SEE). Na testowany obszar składają się cztery podobszary, które można załączyć/odłączyć za pomocą zdalnie sterowanych rozłączników. Celem próby było zdalne wydzielenie i zasilanie obszaru z wykorzystaniem ME, a następnie farmy wiatrowej (FW). Artykuł oparto na wynikach projektu „Budowa lokalnego obszaru bilansowania (LOB) jako elementu zwiększenia bezpieczeństwa i efektywności energetycznej pracy systemu dystrybucyjnego”, realizowanego przy współudziale Energa Operator SA, Uniwersytetu Zielonogórskiego i Instytutu Energetyki Oddział Gdańsk.
EN
The implementation of the "winter package" will contribute to changes in the rules for contracting ancillary services. After 2020, part of the responsibility for the functioning of the power system will be transferred to the level of DSO, for example: regulation of voltage, Fast Reactive Current Injection (FRCI) or services in artificial inertia and system restoration. The article presents the results of tests of power supply system restoration based on energy storage (ES) and distributed renewable sources (wind farms). The attempt of island operation with RES (renewable energy sources) was carried out in a limited area of the power grid. The tested area contained four sub-areas that can be switched on / off using remotely controlled load break switch. The purpose of the test was to remotely isolate the area and feed it using the Energy Storage and then the wind farm (WF). The paper is based on the results of the project The Building of a Local Balancing Area (LBA) as an Element of Increasing Safety and Energy Efficiency of the Distribution System Operation implemented with the participation of Energa Operator SA, the University of Zielona Gora and the Institute of Power Engineering Gdansk Division.
PL
Zarówno w skali światowej, jak i krajowej obserwowany jest wzrost udziału energetyki wiatrowej w strukturze wytwarzania energii elektrycznej. Rozwój ten jest determinowany zarówno postępem technicznym, jak i – w znacznie większym stopniu – wdrażaniem odpowiednich instrumentów polityki klimatycznej. Obecnie wspierane są rozwiązania mające pozytywny wpływ na środowisko, a za takie uważane są odnawialne źródła energii. Należy jednak zwrócić uwagę, że zwiększanie udziału źródeł niesterowalnych w systemie elektroenergetycznym powoduje problemy z planowaniem jego rozwoju i bieżącym sterowaniem. W świetle powyższych uwarunkowań głównym celem artykułu jest analiza wpływu wzrostu poziomu mocy zainstalowanej elektrowni wiatrowych na pokrycie krajowego zapotrzebowania na moc. W artykule przedstawiono również w jakim stopniu wzrost mocy zainstalowanej źródeł wiatrowych wpływa na wartość wskaźnika wykorzystania mocy.
EN
The wind power share in energy systems is increasing each year. This situation takes place both worldwide and in Poland. Currently, the solution with positive impact on the environmental are subsidized. Among them are the renewable energy source. The technology development and implementation of climate policies cause the investments in wind energy grows exponentially. The renewable energy source development has many advantages, such as positive impact on environmental or climate changes. Hoverer, it should also be noted that the appearance the variety resources in energy system lead to challenges with planning and operating. In view of the above, the main purpose of this article is assessment the load carrying capability of wind power plants. Furthermore, the authors point out to what extent the increase of total installed capacity impacts on the possibility its use by transmission system operator.
PL
W artykule przedstawiono wyniki analiz dotyczących możliwości wykorzystania zasobników energii do kompensowania błędów generacji wiatrowej w horyzoncie średnioterminowym w celu poprawy jakości planowania pracy i obniżenia kosztów funkcjonowania systemu elektroenergetycznego. Zaprezentowano metodykę określania preferowanych typów elektrochemicznych magazynów energii na podstawie techniczno–ekonomicznych wskaźników optymalizacji uwzględniających m.in.: charakterystyki czasu życia zasobnika (liczba cykli przy określonym poziomie rozładowania), sprawności cyklu ładowanie - rozładowanie oraz nakładów inwestycyjnych.
EN
Possibility of using energy storage to balance the short and mid-term variability of wind generation in order to improve the quality of planning process and reduce the cost of power system operation was presented in this paper. Continuous rise of wind generation installed capacity causes increase problems associated with power system balancing. One of the countermeasures may be battery energy storage systems (BESS). The aim of the analysis was to determine the preferred battery energy storage system (BESS) technologies based on indicators of energy storage nominal power to wind generation installed capacity (MWES / MWGW) and required energy storage capacity (Q) in relation to its power (Q / P ES). Minimum values of technical or financial indicators were used to identify the optimal solution. The simulations were made taking into account the energy storage lifetime resulting from the number of cycles and depth of discharge. To determine the required BESS parameters were performed short and mid-term wind generation variability compensation simulations for selected, commercially available BESS technologies: sodium - sulfur (NaS), lithium-ion (Li-ion) and lead acid (PbAcid).
PL
Rozwój energetyki odnawialnej wysuwa na pierwszy plan problem z utrzymaniem odpowiedniego poziomu rezerwy mocy w krajowym systemie elektroenergetycznym (KSE). W artykule skoncentrowano się na pokazaniu zależności pomiędzy wybranymi kosztami prowadzenia jednostek wytwórczych centralnie dysponowanych (JWCD) a rozwojem energetyki wiatrowej. Sprawdzono jak wprowadzenie redukcji mocy w farmach wiatrowych (FW) przy różnych granicznych poziomach wpłynie na koszty rozruchów elektrowni konwencjonalnych.
EN
The development of renewable generation raise a question of electric power reserves in Polish national grid. The article is focused on showing the correlations between selected costs of conventional power units and the development of wind generation. The effect of ancillary services of wind farms on electrical power start-up costs was presented.
EN
Development of wind generation, besides its positive aspects related to the use of renewable energy, is a challenge in terms of operational security and economy of the National Power System (NPS). The uncertain and variable nature of wind generation sources (WG) entails the need to ensure by the TSO adequate power reserves, necessary to maintain the stable power system operation. Entities involved in energy trading from these sources incur additional balancing costs of unplanned production deviations. Continuous rise of WG installed capacity causes increase the problems associated with power system balancing. One of the solution may be energy storage systems. The paper presents the results of analyses of the possible use of electrochemical energy storage systems to balance WG variability as a tool to support the power system operation planning, in order to reduce the operating costs of the NPS. The method of determining the preferred types of electrochemical energy storage systems, basis on the technical and economic optimisation indicators was shown in this article.
PL
Rozwój generacji wiatrowej oprócz pozytywnych aspektów związanych z wykorzystaniem energii odnawialnej stanowi wyzwanie z punktu widzenia bezpieczeństwa i ekonomiki funkcjonowania Krajowego Systemu Elektroenergetycznego (KSE). Niepewny i zmienny charakter źródeł generacji wiatrowej (GW) pociąga za sobą konieczność zapewnienia przez OSP odpowiednich rezerw mocy, niezbędnych dla zachowania stabilnej pracy sieci. Podmioty zaangażowane w handel energią z tych źródeł ponoszą dodatkowe koszty bilansowania nieplanowanych odchyleń produkcji. Ciągły wzrost mocy zainstalowanej GW powoduje nasilenie problemów związanych z bilansowaniem systemu, a rozwiązaniem mogą być zasobniki energii. W artykule przedstawiono wyniki analiz dotyczących możliwości wykorzystania elektrochemicznych zasobników energii do bilansowania zmienności GW jako narzędzia wspomagającego planowanie pracy systemu i służącego obniżeniu kosztów funkcjonowania KSE. Zaprezentowano sposób wyznaczania preferowanych typów elektrochemicznych zasobników energii, określanych na podstawie techniczno-ekonomicznych wskaźników optymalizacyjnych.
EN
Intensive development of distributed generation, apart from the positive aspects related to the use of renewable energy, is also a challenge in terms of safety and reliability of energy supply. Ensuring the reliability of supplies, at the variable operation of wind generation and photovoltaic generation, requires from the network operators implement additional costly investments. An alternative solution is to build a system that integrates management of local energy resources (including automatic grid controls, energy storage, local energy sources) in order to optimize the technical possibilities of the grid.
PL
Intensywny rozwój generacji rozproszonej, oprócz pozytywnych aspektów związanych z wykorzystaniem energii odnawialnej, stanowi wyzwanie z punktu widzenia bezpieczeństwa i funkcjonowania Krajowego Systemu Elektroenergetycznego (KSE). Zapewnienie niezawodności dostaw, przy zmiennym charakterze pracy generacji wiatrowej i fotowoltaicznej, wymusza na operatorach sieci konieczność realizacji dodatkowych kosztownych inwestycji sieciowych. Alternatywnym rozwiązaniem jest budowa systemu umożliwiającego zintegrowane zarządzanie lokalnymi zasobami energetycznymi (m.in. automatyką sieciową, magazynami energii, lokalnymi źródłami energii) w celu optymalizacji technicznych możliwości sieci elektroenergetycznej.
PL
W artykule przedstawione zostały wyniki analizy współzależności poziomów generacji wiatrowej i potencjalnej generacji fotowoltaicznej na obszarze sieci ENERGA-OPERATOR SA. W roku 2012 Instytut Energetyki Oddział Gdańsk we współpracy z ENERGA-OPERATOR SA przeprowadził pierwsze badania dotyczące zależności poziomów generacji ww. rodzajów źródeł odnawialnych. Jednym z wniosków pracy było wskazanie konieczności powtórzenia analizy dla większego zbioru danych wejściowych, jako że studium obejmowało okres jednego roku i ograniczoną z oczywistych względów liczbę lokalizacji farm wiatrowych. W prezentowanych badaniach dane wejściowe obejmowały okres czterech lat oraz większą liczbę farm wiatrowych, z uwagi na ciągłe przyłączanie kolejnych obiektów do sieci. Otrzymane wyniki charakteryzują się znacznie wyższym poziomem wiarygodności oraz pozwalają na wyciągnięcie bardziej prawidłowych wniosków dotyczących współzależności będącej przedmiotem badania. Z przeprowadzonych badań zależności rocznych przebiegów poziomów generacji wiatrowej i potencjalnej generacji ze źródeł fotowoltaicznych wynika, że oba typy generacji charakteryzują się wzajemną, obszarową zależnością. W ramach pracy związek ten został skwantyfikowany poprzez wyznaczenie wartości maksymalnego realnego poziomu generacji wiatrowej na poszczególnych obszarach w przypadku wysokiej generacji PV na danym obszarze i vice versa. Otrzymane wyniki mogą pozwolić na uprawdopodobniające modelowane stany pracy systemu w stosunku do rzeczywistości obu typów źródeł w różnych rodzajach analiz systemowych badających ich wpływ na sieć.
EN
This paper presents the results of a study aiming to analyze the correlation between output levels of generation of wind farms located in northern Poland (area where the grid is operated by ENERGA-OPERATOR SA) and potential photovoltaic installations in the same area. With the recent increase of interest in investing in PV in Poland, it has become very important to investigate the likelihood of wind and PV generation installed over a large area to generate a high level of power simultaneously. The first study investing the potential correlation of mentioned two types of renewable sources in the area has been performed by the Institute of Power Engineering in cooperation with ENERGA-Operator SA in 2012. Nevertheless, as the previous study covered a period of only one year, due to a limited amount of available data, it has become necessary to continue the analysis as more data becomes available with new wind farms being connected to the grid. In this paper, the findings of a new study, where data from a four-year period was used, are presented.
PL
Polityka energetyczna Polski określa, że do 2030 roku około 7% generacji energii w kraju ma pochodzić ze źródeł wiatrowych. Artykuł nakreśla wyzwania związane z prognozowaniem generacji z tego źródła energii. Celem artykułu jest przestawienie metodyki i wyników prognozowania generacji energii ze źródeł wiatrowych, w której nowatorsko połączono trzy metody prognozowania. W pierwszym etapie wykorzystano regresję nieliniową opartą na funkcji logistycznej do budowy profilu generacji turbiny. Etap drugi oparto o regresję lokalną, która buduje właściwy model prognostyczny. W ostatnim kroku wykorzystano metodę korekty błędem w celu minimalizacji błędów prognozy wynikających z nietypowego zachowania turbiny. Metodyka prezentowana w artykule jest wynikiem projektu Future Energy Management System, w którym m.in. przebadano dane generacji z dużej farmy wiatrowej zlokalizowanej w zachodniej Polsce. Ponadto, artykuł wskazuje na wyzwania związane ze zmiennością czynników atmosferycznych i zużyciem własnym siłowni wiatrowej, które często w wyniku braku sprofilowania turbiny jest także trudno przewidywalne.
EN
The Energy Policy for Poland states that by 2030 about 7% of power generation in the country will have to be provided from the wind. This article describes challenges associated with forecasting the energy generation from this energy source. The purpose is to present the methodology, together with forecasting results, which innovatively combined three methods of forecasting. In the first step of the methodology, we use non-linear regression based on the logistic function to construct the profile of turbine energy generation. The second stage is based on the local regression that contributes to the main forecasting model. In the last step the error correction method was used to minimize the forecast errors resulting from the abnormal behavior of the turbine. The methodology presented in the article is a result of Future Energy Management System Project, in which among others, research using data of a large wind farm located in western Poland was performed. In addition the article discusses the challenges of the variability of the weather and related wind turbine energy consumption, which is often difficult to predict due to the lack of turbine profiles.
PL
Celem artykułu jest przedstawienie nowej metody szacowania możliwości przyłączeniowych generacji wiatrowej do Krajowego Systemu Elektroenergetycznego oraz zbadanie bilansowania KSE przy uwzględnieniu różnych wartości mocy zainstalowanej w farmach wiatrowych. Autorzy dokonali próby opracowania kryterium, według którego mogłaby być wyznaczana graniczna wartość dopuszczalnej mocy zainstalowanej w generacji wiatrowej i przyłączanej do KSE.
EN
The aim of the paper is to present a new method for assessing connection potential of wind power generation to the National Power System (NPS) and an analysis of power balancing in NPS taking into account varying values of the installed power in wind farms. The authors have attempted to develop a criterion to make a basis to determine a boundary value of allowed installed power in wind farms and connected to NPS.
EN
The objective of the analysis was the quality of electric energy in the place of attachment of a single wind power plant to the electricity grid. This objective was performed based on the author's own research carried out in a LV switching station located in the place of attachment of a wind turbine with the power 150 kW to the MV distribution network. The object of the research was located in the northern part of Małopolskie Voivodeship. The assessment of the quality of electric energy was carried out based on the requirements set forth in the Ordinance of the Minister of Economy on detailed conditions of functioning of the power system and the Manual of Movement and Operation of Distributive Network. Based on the analysis, which was carried out, one may assume that the requirements referring to frequency changes, efficient value of the supply voltage, voltage unbalance and its deformation from the sinusoidal waveform have been met. In the period which was covered by the research, during the wind turbine work, insignificant surpasses of the admissible level of the root mean square of voltage were reported, but their number constituted less than 0.07% of observations. During the research, also 20 voltage dips of values exceeding 10% of the rated voltage, average depth of which was 172V were reported. In majority these were disruptions caused by other receivers connected to the network.
PL
Celem pracy była analiza jakości energii elektrycznej w miejscu przyłączenia pojedynczej siłowni wiatrowej do sieci elektroenergetycznej. Cel ten zrealizowano na podstawie badań własnych wykonanych w rozdzielni nN, zlokalizowanej w miejscu przyłączenia siłowni wiatrowej o mocy 150 kW do sieci rozdzielczej SN. Obiekt badań był zlokalizowany w północnej części województwa małopolskiego. Oceny jakości energii elektrycznej dokonano w oparciu o wymagania zawarte w Rozporządzeniu Ministra Gospodarki w sprawie szczegółowych warunków funkcjonowania systemu elektroenergetycznego oraz Instrukcji Ruchu i Eksploatacji Sieci Dystrybucyjnej. Na podstawie wykonanych analiz można uznać, że wymagania odnośnie zmian częstotliwości, wartości skutecznej napięcia zasilającego, asymetrii napięcia oraz jego odkształcenia od przebiegu sinusoidalnie zmiennego zostało spełnione. W okresie objętym badaniem podczas pracy siłowni wiatrowej rejestrowano nieznaczne przekroczenia dopuszczalnego poziomu wartości skutecznej napięcia, ale ich liczba stanowiła niespełna 0,07% obserwacji. W czasie badań zarejestrowano również 20 zapadów napięcia o wartościach przekraczających 10% napięcia znamionowego, których średnia głębokość wynosiła 172V. W większości były to zakłócenia, których źródłem są inne odbiorniki przyłączone do sieci.
EN
The paper presents a new approach to the problem of optimizing wind generation distribution in cases of overloads in the grid caused by high level of wind generation. The approach is based on a modified and enhanced version of a genetic algorithm presented at the previous “Aktualne Problemy w Elektroenergetyce” (APE) [Present-Day Problems of Power Engineering] conference in 2011. The idea of coherent a grid nodes is introduced in order to optimize generation levels for groups of wind farms instead of individual wind farms, enabling grid operators to distribute power reduction among wind farms in a more equal manner, which can result in enabling larger wind generation penetration in grid with low transmission capacities. The test results as well as results obtained using the algorithm for a real-life, large-scale case are also presented.
PL
Autorzy prezentują nową metodę wyznaczania optymalnego rozkładu generacji wiatrowej, opartą na rozwinięciu algorytmu genetycznego – prezentowanego podczas konferencji „Aktualne Problemy w Energetyce” w 2011 roku (APE) – o ideę koherentnych węzłów sieci. Metoda pozwala na bardziej równomierne rozłożenie redukcji mocy między pobliskie farmy, przy jednoczesnym zachowaniu zalet oryginalnego podejścia. Nowy algorytm optymalizuje poziomy generacji zdefiniowanych a priori grup farm. W artykule prezentowane są również wyniki uzyskane za pomocą algorytmu w trakcie symulacji przewidywanej pracy sieci północnej Polski w horyzoncie kilku lat.
PL
W artykule prezentowana jest nowa metoda wyznaczania optymalnego rozkładu generacji wiatrowej, oparta na rozwinięciu prezentowanego na konferencji APE’11 algorytmu genetycznego o ideę koherentnych węzłów sieci. Metoda pozwala na bardziej równomierne rozłożenie redukcji mocy między pobliskie farmy przy jednoczesnym zachowaniu zalet oryginalnego podejścia. Nowy algorytm optymalizuje poziomy generacji zdefiniowanych a priori grup farm. W artykule prezentowane są również wyniki uzyskane za pomocą algorytmu w trakcie symulacji przewidywanej pracy sieci północnej Polski w horyzoncie kilku lat.
EN
The paper presents a new approach to the problem of optimizing wind generation distribution in case of overloads in the grid caused by high level of wind generation. The approach is based on modified and enhanced genetic algorithm presented at the previous APE conference in 2011. The idea of coherent grid nodes is introduced in order to optimize generation levels for groups of wind farms instead of individual wind farms, enabling grid operators to distribute power reduction among wind farms in a more equal manner, which can result in enabling larger wind generation penetration in grid with low transmission capacities. The test results as well as results obtained using the algorithm for a real-life, large-scale case are also presented.
PL
W artykule dokonano oceny możliwości wytwórczych farm wiatrowych mających powstać na terenie województwa lubelskiego, w oparciu o przebiegi prędkości wiatru z lat 2006, 2007, 2008 uzyskane z atlasu wiatru AnemosŽ. Otrzymane wyniki poddano analizie i przedstawiono realne do osiągnięcia przez te farmy wartości mocy oraz energii elektrycznej.
EN
In this article we discuss the possibilities of electricity generation by wind farms settled in lubelskie province. Our study are based on detailed wind velocities map of Poland - AnemosŽ. We analyzed data in period from 2006 to 2008 and calculated feasible values of power and energy that may be obtained from the wind farms in chosen locations of province.
PL
W artykule przedstawiono wyniki analizy pracy farm wiatrowych w Polsce, po osiągnięciu hipotetycznego poziomu 12000 MW mocy zainstalowanej. Wykorzystano lokalizacje farm określone na podstawie uzyskanych warunków przyłączenia do sieci oraz warunki wietrzności określone za pomocą systemu Anemos. Na podstawie tych warunków dla każdej lokalizacji oszacowano, że maksymalny poziom generacji wiatrowej (9000 MW) może wystąpić nie dłużej niż 1000 godzin rocznie, natomiast przez blisko 6000 godzin w roku moc generowana nie przekroczy 4000 MW. Wyniki te powinny być brane pod uwagę przy szacowaniu oddziaływania energetyki wiatrowej na system elektroenergetyczny. W artykule do-konano także analizy możliwych do wystąpienia ograniczeń bilansowych generacji wiatrowej na podstawie hipotetycznego obciążenia KSE w roku 2020. Celem niniejszego artykułu było także przeanalizowanie dynamiki zmian obciążenia SEE oraz próba odpowiedzi na pytanie, czy generacja wiatrowa znacząco pogarsza warunki pracy jednostek konwencjonalnych, co często jest podnoszone przez jej przeciwników.
EN
The paper shows the results of analysis taking into account wind generation of 12 000 MW installed power in Poland by the 2020 year. Wind farms with issued actual conditions of interconnection into the HV grid have been taken into consideration. Generated power variation analysis has shown that the maximal level of wind generation (9,000 MW) is expected over 1,000 hours of the year, while the rest of 6,000 hours a year of total generated wind power have been expected lower than 4,000 MW. Those results should be taken into consideration when estimating an influence of wind generation on a power system. In this article the analysis of potential power system balance limitations for wind farms have been elaborated based on appropriate scaling of system load to level for year 2020 and estimated wind generation. The aim of this work was also an analysis of mean hour load gradients of the power system before and after interconnecting the mentioned 12 000 MW of wind generation to the system and an attempt to answer the question whether the wind generation, would be destabilizing to power system or would not.
PL
W referacie przedstawiono analizę możliwości przesyłowych linii napowietrznych wykorzystując tzw. dynamiczną obciążalność termiczną linii. Obciążalność ta jest m.in. zależna od prędkości wiatru chłodzącego przewody. Powiązanie możliwości wykorzystania rezerw przesyłowych wynikających z większych prędkości wiatru niż przyjęta projektowo sprzyja źródłom wykorzystujących wiatr jako energię pierwotną. Referat zawiera wyniki obliczeń opartych na rzeczywistych danych pomiarowych oraz ocenę obszarową jednolitości tych danych. Na podstawie tych wielkości oceniono w tych warunkach rzeczywistą obciążalność linii napowietrznych oraz potencjał wytwórczy elektrowni wiatrowych.
EN
The analysis of overhead lines capacity based on dynamic thermal line rating was presented in the paper. Dynamic thermal rating is directly connected with wind velocity thus the wind power plants are beneficiaries of this effect. The paper presents some calculations based on measured wind velocity concerning assessment of area dimension. The calculations show increasing of line rating in accompany with in increasing of potential wind generation.
EN
This paper presents the survey of the smart grid technologies, including the background, motivation and practical applications. The driving forces for the smart grid technologies are presented, including the blackout, global energy crisis and environmental protection requirement. The key technology issues for building the smart grid are discussed. The crucial elements of the smart grid and their applications are introduced, including the un-interruptible power supply (UPS), adaptive var compensator (AVC), static synchronous compensator (STATCOM), active power filter (APF), unified power quality conditioner (UPQC), micro-grid, solar and wind generation, and high voltage direct current (HVDC) transmission technologies.
PL
Artykuł prezentuje przegląd technologii smart grid”. Uwzględniono takie zjawiska jak blackout, globalny kryzys energetyczny i zalecenia ochrony środowiska. Omówiono podstawowe elementy sieci „smart grid” i jej zastosowania, uwzględniając systemy UPS, AVC, STATCOM, APF, UPQC, źródła słoneczne i wiatrowe oraz technologię transmisji napięcia stałego HVDC.
EN
This paper describes two algorithms applied for active and reactive power control in wind turbine driven doubly fed induction generator (DFIG). The first proposed method applies the PI controllers for regulation of DFIG power and the rotor current while the second one utilizes a difference approximation of a given flux derivative. Both algorithms are based on the model description with reference to the stator flux linkage frame. General description of the analyzed methods is delivered and some results of simulations are included.
PL
W artykule przedstawiona jest analiza dwóch algorytmów stosowanych do regulacji mocy czynnej i biernej w elektrowniach wiatrowych z dwustronnie zasilanymi generatorami indukcyjnymi. W pierwszej rozważanej metodzie stosowane są regulatory PI do kontroli mocy i prądu wirnika, podczas gdy w drugiej - całkowanie ciągłe jest aproksymowane za pomocą zależności przyrostowych. W obu algorytmach model maszyny jest zapisany względem układu współrzędnych związanych ze strumieniem stojana. Zamieszczony jest opis rozważanych modeli oraz wyniki przeprowadzonych symulacyjnych testów.
PL
W artykule przedstawiono model matematyczny optymalizacji węzłowej generacji wiatrowej w sieci przesyłowej. Funkcją celu jest maksymalna sumaryczna generacja wiatrowa przy spełnieniu następujących ograniczeń: dopuszczalne obciążenie linii i transformatorów, dopuszczalne saldo wymiany zagranicznej, regulacyjne minimum techniczne mocy w elektrowniach konwencjonalnych. Rozważania zilustrowano przykładem obliczeniowym.
EN
This article presents the mathematical model of node optimisation for wind generation in the transmission grid. The target function is the maximum summary wind generation with compliance with the following bounds the permissible load of lines and transformers, the permissible foreign exchange balance, the minimum technical regulating power at conventional power plants. The considerations are illustrated by an example calculation.
PL
W artykule przedstawiono krótką dyskusję dotyczącą definicji generacji rozproszonej. Nakreślono stan obecny oraz perspektywy rozwoju generacji rozproszonej w Polsce. Opisano możliwości pozyskania jednostek generacji rozproszonej do celów sterowania pracą systemu elektroenergetycznego, poprzez świadczenie usług systemowych.
EN
This paper presents a method for the short-circuit parameter estimate in a network including wind power plants. The originality of the method consists in the treatment of wind generators (as well as whole farms) as current sources that “inject” to grid network in the connection node an inductive current being a multiple of the rated current of a single generator (or a group of generators, respectively). This behaviour occurs when the voltage in the generator connection point has dropped below a certain level. Thus, the traditional generator short-circuit model in the form of electromotive force is replaced with a voltage-controlled current source.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.