Content available remote Paroprzepuszczalność zaizolowanych przegród budowlanych
PL
W artykule autorka tłumaczy, co odpowiada za zjawisko przemieszczania się wilgoci, jakie parametry wskazują zdolność materiału do wszechobecnie stosowanego terminu „oddychania” i co zrobić, żeby uniknąć kłopotów.
EN
In the article, the author explains the factors responsible for the phenomenon of moisture movement, lists the parameters indicating the material’s ability to breathe (a ubiquitously used term), and advises what to do to avoid problems.
EN
The subject of the article is the influence of filament moisture on the quality of products manufactured using the additive method using the Fused Deposition Modelling (FDM) method. Three types of thermoplastic polymers were tested: ABS, PLA and PET-G. The polymers were stored in environments with different humidity. The moisture content of the filament was determined as the water content in the material expressed as a percentage by weight. To obtain the expected humidity of the samples, they were conditioned for 7 days in tightly closed containers with constant humidity of 40%, 60% and 80%. After the sample conditioning process was completed, they were removed from the container and subjected to further tests. The influence of filament humidity on selected properties of manufactured products is presented, such as: surface quality of the obtained samples, tensile strength and dimensional repeatability. To sum up, the method of storing the filament affects the moisture content of the filament. The humidity of the filament, in turn, affects the quality of products manufactured using the FDM method, including: on: mechanical properties, dimensional stability, Surface appearance. Therefore, it is important in what conditions the filament is stored before the production process begins.
3
Content available Vibrating moistening of wheat grain
EN
The article experimentally established the influence of amplitude, frequency and duration of processing on the efficiency of vibratory wetting of wheat. With increasing amplitude and frequency of oscillations, as well as the duration of processing, the increase in moisture in the grain increases nonlinearly. With oscillation amplitudes of 10 and 20 mm and constant frequency of 10 Hz and processing duration of 8 min., Wheat grain increased moisture by 2.1%. Processing time more than 8 min. does not increase the moisture content of wheat. The largest increase in moisture in wheat was observed at an oscillation frequency of 12 Hz and an amplitude of 20 mm and a treatment duration of 5 min. Increasing the oscillation frequency more than 12 Hz did not lead to an increase in wheat moisture. It was found that the load does not affect the efficiency of moistening wheat grain.
PL
Artykuł prezentuje wyniki analizy wpływu zawilgocenia cegły ceramicznej na współczynnik przewodzenia ciepła i wskazuje na problem, jakim jest oddziaływanie zawilgocenia przegród zewnętrznych na zmianę temperatury wewnętrznej powierzchni przegrody i wielkość strat ciepła. Wzrost stopnia zawilgocenia przegrody powoduje wzrost wartości współczynnika przenikania ciepła, co wpływa bezpośrednio na obniżenie temperatury wewnętrznej powierzchni ściany zewnętrznej i odczucia cieplne użytkowników budynków oraz na temperaturę operatywną. Dodatkowo w razie obniżenia temperatury powierzchni ściany poniżej temperatury punktu rosy występuje wykroplenie się wilgoci na powierzchni ściany, co przy braku prawidłowo działającej wentylacji prowadzi do rozwoju grzybów pleśniowych. Chcąc zapobiec wystąpieniu w analizowanym budynku negatywnych skutków niekorzystnego obniżenia temperatury przegrody, zaproponowano docieplenie ścian od zewnątrz. Po dociepleniu budynku konieczna jest modernizacja istniejącej instalacji grzewczej i dopasowanie jej do nowych, obniżonych wartości strat ciepła. Zaproponowano nowe wielkości grzejników oraz nowe źródło ciepła.
EN
The article presents the results of an analysis of the effect of moisture on the heat transfer coefficient of a clay brick, and points out the problem of how moisture in the building envelope affects the change in the temperature of the internal surface of the wall and the amount of heat loss. An increase in the amout of moisture content of the building material results in a higher value of the thermal conductivity coefficient, which causes an increase in the heat transfer coefficient and thus also in the transmission heat loss of the building. A higher value of heat transfer coefficient has a direct effect on lowering the temperature of the inner surface of the exterior wall, which has a significant impact on the thermal sensations of building occupants by affecting the operative temperature. In addition, when the wall surface temperatureis lower than the dew point temperature, moisture condensation occurs on the wall surface, which, in the absence of properly functioning ventilation, leads to the development of mold. In order to prevent the occurrence in the analyzed building of the negative effects of an unfavorable decrease in the temperature of the partition, it was proposed to insulate the walls from the outside. After insulating the walls, it is necessary to modernize the existing installation and adjust it to the new reduced heat loss values of the building. New radiator sizes and a new heat source have been proposed.
6
Content available remote Warstwy poślizgowe w wytycznych dekarskich
7
Content available remote Specyfika dachów
PL
W niniejszej pracy badana jest zmienność napięcia przebicia biodegradowalnego oleju transformatorowego stosowanego w urządzeniach wysokonapięciowych w określonych warunkach eksperymentu. Napięcia przebicia oleju transformatorowego mierzone były dla różnej liczby przebić w serii pomiarowej, różnej geometrii elektrod i różnego poziomu zawilgocenia. Wyniki badań wykazały, że napięcie przebicia oleju estrowego w polu jednorodnym jest zależne od geometrii elektrod, zarówno dla oleju suchego jak i zawilgoconego.
EN
This work investigates the variability of the breakdown voltage of biodegradable transformer oil used in high-voltage devices under specific conditions of the experiment. The breakdown voltages of transformer oil were measured for different numbers of breakdowns in the measurement series, different electrode geometries and different levels of moisture. The test results showed that the breakdown voltage of ester oil in a homogeneous field depends on the geometry of the electrodes, both for dry and moist oil.
PL
W artykule przedstawiono prace nad wykorzystaniem metody miareczkowania kulometrycznego Karla Fischera z odparowaniem do oznaczania zawartości wody w biomasie. Przeprowadzono badania sześciu rodzajów próbek biomasy roślinnej: zmielonej kawy otrzymanej jako odpad po zaparzeniu, słomy pszenicznej, siana, łupin orzecha włoskiego oraz zrębków drewna leszczynowego i świerkowego. Wykonano badania zawartości wody we wszystkich pozyskanych produktach i porównano wyniki z wynikami otrzymanymi dwiema innymi metodami stosowanymi standardowo do badania wilgoci w biomasie, tj. metodą wagosuszarkową i destylacyjną. Stwierdzono, że wszystkie metody wykazały dobrą zgodność w zakresie wyników uzyskanych dla przebadanych próbek. Najmniej przydatna okazała się metoda destylacyjna, której rezultaty najbardziej odbiegały względem pozostałych metod. Wykonanie analizy tą techniką wymaga długiego czasu, jest ona dość pracochłonna i niezautomatyzowana. Najszybszą techniką jest metoda wagosuszarkowa, ale cechuje ją mniejsza precyzja w stosunku do metody kulometrycznej. Wyniki otrzymane tą metodą mogą być zawyżone ze względu na to, że miarą zawartości wody w badanej próbce jest ubytek masy, który może być związany nie tylko z obecnością wody, ale także z innymi lotnymi substancjami uwalnianymi w trakcie badania. Metoda miareczkowania kulometrycznego Karla Fischera jest natomiast metodą selektywną i podczas analizy oznaczana jest tylko woda odparowywana z próbki, nawet gdyby z próbki uwalniały się jeszcze inne substancje lotne w warunkach badania. Metoda miareczkowania kulometrycznego Karla Fischera z odparowaniem próbki w piecyku wykazała się największą precyzją. Jest łatwa w wykonaniu i zautomatyzowana. Stwierdzono, że metoda ta może być z powodzeniem stosowana w badaniu biomasy. Zawartość wody we wszystkich pozyskanych próbkach biomasy wahała się w przedziale od 8% do 10,5% (m/m). W celu zbadania możliwości oznaczenia zawartości wody w szerszym zakresie pomiarowym próbki biomasy suszono w suszarce laboratoryjnej w ciągu 4 godzin w temperaturze 105°C oraz dodatkowo przygotowano próbki modelowe o różnej zawartości wody z wykorzystaniem zmielonej kawy jako matrycy. Na przygotowanych próbkach wykonano badania wilgoci metodą miareczkowania kulometrycznego Karla Fischera z odparowaniem. Przeprowadzone badania potwierdziły, że metoda ta świetnie nadaje się do badania próbek biomasy. Charakteryzuje się bardzo dobrą powtarzalnością w badanym zakresie od 0,7% do 75% (m/m).
EN
The article presents works on the use of coulometric Karl Fischer titration with evaporation for determining water content in biomass. Six types of plant biomass samples were tested: ground coffee obtained as brewed waste, wheat straw, hay, walnut shells and hazel and spruce wood chips. Tests of water content in all obtained products were carried out and their results were compared with two other methods used as standard for biomass moisture testing, i.e. by using a drying balance method and the distillation method. All the methods were found to be in good agreement with the results obtained for the samples tested. The distillation method turned out to be the least useful, as it gave results that differed most from the other methods. The analysis time using this technique is long, it is quite laborious to perform and is not automated. The fastest technique is the method utilizing a drying balance, but it is less precise than the coulometric method. The results obtained with this method may be overestimated as the measure of water content in the tested sample is the loss of mass, which may be related not only to the presence of water, but also to other volatile substances released during the test. On the other hand, the coulometric Karl Fischer titration method is selective and only the water evaporated from the sample is determined during the analysis, even if other volatile substances are released from the sample under the test conditions. The coulometric Karl Fischer titration method with sample evaporation in an oven showed the best precision. It is easy to make and automated. It was found that this method can be successfully used in biomass research. The water content in all obtained biomass samples ranged between 8 and 10.5% (m/m). In order to investigate the possibility of determining the water content in a wider measuring range, the biomass samples were dried in a laboratory dryer for 4 hours at 105°C, and additionally, model samples with different water content were prepared using ground coffee as a matrix. The prepared samples were tested with coulometric Karl Fischer titration with evaporation method. The conducted research confirmed that the method of coulometric Karl Fischer titration with evaporation is perfect for testing biomass samples. It is characterized by a very good repeatability in the tested range, from 0.7 to 75% (m/m).
10
PL
W artykule omówiono istotne w aspekcie wykonywania ekspertyz zagadnienia decydujące o postępowaniu w renowacji budynków z wilgotnymi murami. Na wybranych przykładach renowacji podano sposoby przedostawania się wilgoci do konstrukcji obiektu. Wskazane zostały konkretne rozwiązania mające na celu eliminację źródła zawilgocenia. Przedstawiono sposób działania systemu tynków renowacyjnych jako rozwiązania skutecznie poprawiającego osuszanie murów i eliminację szkodliwych soli.
EN
The article presents the impact of moisture on the degradation of historic buildings. On selected examples of renovation, methods of moisture penetration into the structure of the building have been presented. Article presents also specific solutions to eliminate the source of moisture. The method of operation of the renovation plaster system as a solution that effectively improves the drying of walls and the elimination of harmful salts is presented.
PL
Projektując przegrody zewnętrzne budynku należy poddać analizie wiele różnych aspektów, takich jak efektywność energetyczna, trwałość, możliwość zbudowania takiej przegrody, wpływ na warunki zdrowotne i zapewnienie komfortu osób przebywających w budynku, bezpieczeństwo pożarowe, akustyka oraz aspekt finansowy. W artykule autorzy analizują kwestie związane z efektywnością energetyczną i procesami cieplno-wilgotnościowymi przegród. Inne tematy poruszane w tym artykule to wpływ przegród na jakość środowiska wewnętrznego.
EN
When designing the building envelope, many different aspects should be analyzed, such as energy efficiency, durability, the possibility of constructing such divisions, the impact on health conditions and ensuring the comfort of people in the building, fire safety, acoustics and the financial aspect. In the article, the authors analyze the issues related to energy efficiency and thermal and humidity processes in partitions. Other topics covered in this review article are the effects of partitions on the quality of the indoor environment.
PL
Ustalanie oceny i charakteru ryzyka dla zidentyfikowanych czynników jest kluczowym działaniem w celu trafności decyzji w późniejszych krokach związanych z wdrażaniem adekwatnych działań zaradczych.
PL
W artykule przedstawiono wyniki analiz ramowej konstrukcji nośnej hali sportowej z drewna klejonego warstwowo, w której doszło do uszkodzenia strefy przypodporowej jednej z podpór zewnętrznych. Mimo że uszkodzenia pojawiły się 30 lat temu, konieczna okazała się kontrola istniejącego stanu elementów konstrukcyjnych, a szczególnie fragmentów narażonych na działanie czynników atmosferycznych. W ramach prac badawczych przeprowadzono oraz opisano badania materiałowe i wilgotnościowe drewna, pomiary geodezyjne ram oraz wykonano ocenę statyczno-wytrzymałościową konstrukcji. Wykazano, że niezbędne jest zmodyfikowanie i wzmocnienie strefy przypodporowej ramy wraz z odpowiednią konserwacją wszystkich fragmentów zewnętrznych, a także zalecono dalszą kontrolę pracy dźwigara.
EN
The paper presents the results of the analysis of the frame structure of sports hall, made of glued laminated timber, in which the support zone of one of the external supports was damaged. Although the damage occurred 30 years ago, it was necessary to control the existing condition of the structural elements, especially the parts exposed to weathering. The research work included material and moisture testing of the timber, geodetic measurements of several frames and static-strength analysis of the construction. It was shown that the support zone of the considered frame should be modified and strengthened and that all external sections of the structure should be properly preserved. In addition, further inspection of the girder behavior was recommended.
14
Content available remote Wilgoć w budynkach – mity i rzeczywistość
15
Content available remote Osuszanie oraz izolacje wtórne i techniki wodochronne stosowane w budynkach
PL
O bezawaryjnej pracy obiektów budowlanych decyduje wiele czynników, a wśród nich ważną rolę odgrywają warunki cieplno-wilgotnościowe, w jakich pracują. W przypadku obiektów starych, projekt uwzględniał ten problem tylko fragmentarycznie, a przecież zmieniająca się z upływem czasu eksploatacja lub powstające kataklizmy często powodowały tworzenie się ognisk wilgoci, a w konsekwencji pojawianie się procesów korozyjnych, w tym mikrobiologicznych wywoływanych przez grzyby domowe, pleśniowe, glony i porosty oraz wirusy i bakterie. Problemy sanitarne stają się wówczas istotne, a uzupełniają je korozja chemiczna i elektrochemiczna. Konieczne jest wówczas osuszanie obiektów i wykonanie izolacji wtórnych.
EN
About the work of objects without damage decides many agents, first of all thermal-moisture conditions in buildings. In the old building the reason of this problem was the fragmentary design and after all in time and exploitation of objects. It caused occasion to produce some moisture places and in consequence – corrosion and first of all biological corrosion. The microbiological processes are produced by house fungi and moulds, algae, lichens and bacteria. Moisture and biological agents imply the sanitary problems. The chemical and electrochemical corrosion of materials at past was implicated and at present is also implicated. In this instance, it is necessary to execute the drying of walls and repeated isolations.
16
Content available remote Materiały i technologie do renowacji zawilgoconych murów
PL
W artykule przedstawiono wpływ wilgoci na degradację zabytkowej tkanki obiektów historycznych. Omówiono mechanizm przedostawania się wilgoci do murów. Zaprezentowano rozwiązania materiałowe mające na celu eliminację źródeł zawilgocenia obiektów, sposoby osuszania murów oraz system tynków renowacyjnych. Zwrócono uwagę na konieczność indywidualnego podejścia do budynków zabytkowych oraz poprzedzenie prac renowacyjnych wnikliwą analizą.
EN
The article presents the impact of moisture on the degradation of the of historical buildings. The mechanism of moisture penetration into the walls is presented. There are presented solutions aimed at the elimination of the sources of the dampness in the objects, the methods of drying the walls and the renovation plaster system. Emphasized the need for an individual approach to historic buildings and to precede renovation works with a thorough analysis.
17
Content available remote Zasady projektowania docieplania budynków od wewnątrz
PL
Przedmiotem artykułu są zasady projektowania docieplania budynków od wewnątrz. Autor analizuje zagadnienia ochrony przed wilgocią i fizyki budowli oraz dokonuje oceny stanu istniejącego i fizycznej oceny systemu termoizolacji wewnętrznej. Podaje również ogólne informacje dotyczące planowania.
EN
The article discusses the principles of designing building insulation from the inside. The author analyses the issues of protection against moisture and building physics, and assesses the existing condition and physical state of the internal thermal insulation system. The author also provides general information on planning.
18
Content available remote Tynki stosowane na zawilgoconych przegrodach - tynki regulujące zawilgocenie
PL
Przedmiotem artykułu są tynki regulujące zawilgocenie, stosowane na zawilgoconych przegrodach. Autor wyróżnia tynki renowacyjne oraz tynki regulujące zawilgocenie i dokonuje porównania ich właściwości. Omawia także zasadę działania tynku renowacyjnego oraz tynku regulującego zawilgocenie.
EN
The subject of this paper is damp control plasters used on damp partitions. The author identifies restoration plasters and damp control plasters and compares their properties. He also discusses the operation principle of restoration plaster and damp control plaster.
19
Content available remote Przygotowanie podłoży pod prace glazurnicze
PL
Przedmiotem artykułu są podłoża pod prace glazurnicze. Autor porusza trzy kluczowe zagadnienia: znaczenie równego podłoża, wyrównanie chłonności podłoża oraz zabezpieczenie przed wilgocią. Omawia także tematy układania płytek na gołe mury, tynki i podłogi.
EN
The subject of the article are substrates for laying tiles. The author discusses three key issues: the importance of even surface, levelling the absorbency of the substrate and protection against moisture. He also discusses the topics of laying tiles on bare walls, plaster and floors.
EN
In the design of innovative, protective clothing, thermal comfort is of great importance. One of the key factors affecting thermal comfort is the thermal conductivity of clothing. This study aims to show through theoretical estimations that the effective thermal conductivity of moist clothing could expedite the development process. In this study, we present two theoretical models: a linear model and upgraded model. The upgraded model considers the thermal conductivity of air within the clothing and its volume porosity. For verification of the models presented, the impact of moisture on the thermal conductivity of cotton knit fabric was examined experimentally using the contact hot plate method. Correlation analysis shows that the upgraded model has an important advantage as it can predict the stabilisation of effective thermal conductivity.
PL
W projektowaniu nowatorskiej odzieży ochronnej duże znaczenie ma komfort termiczny. Jednym z kluczowych czynników wpływających na komfort cieplny jest przewodnictwo cieplne odzieży. W pracy omówiono dwa modele teoretyczne: liniowy i ulepszony. Ulepszony model uwzględnia przewodność cieplną powietrza w odzieży i jej porowatość. W celu weryfikacji przedstawionych modeli zbadano doświadczalnie wpływ wilgoci na przewodnictwo cieplne dzianiny bawełnianej metodą kontaktową na gorąco. Analiza korelacji pokazała, że ulepszony model ma ważną zaletę, otóż może przewidywać stabilizację efektywnej przewodności cieplnej.