Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  wielodrożność
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available LC phase bias investigation of ASG-EUPOS stations
EN
Monitoring of permanent stations that make up the reference frame is an integral part of the geodesists work. Selection of reference stations is based on analysis of parameters characterizing them (hardware, coordinates’ stability, mounting, location). In this paper, we took into account phase residual as an indicator of unmodelled signal. Phase residuals were computed based on ASG-EUPOS and EPN observation processing. The results show the connection between the method of mounting the antenna and the residuals. We have reviewed multipath effect at ASG-EUPOS stations, and chosen those which are characterized by the highest value of phase residual. The results show that LC phase residual is a good factor to characterize site’s solutions’ reliability. For majority of sites RMS values were less than 10 mm. Modulations associated with multipath effect were observed for few ASG-EUPOS sites only. Phase residuals are distributed specifically for sites, which antennas are mounted on pillars (more common for EPN sites). For majority of analysed sites phase residual distribution was similar for different days and did not depend directly on atmosphere condition.
PL
Monitorowanie permanentnych stacji GPS/GNSS, które tworzą układ współrzędnych stanowi integralną część pracy geodetów. Wybór takich stacji bazuje na analizie parametrów, które charakteryzują jej jakość (mi.in. sprzęt, stabilność współrzędnych, lokalizacja i montaż anteny). W przedstawionej pracy przeanalizowano jeden z nich – odchyłki obserwacji fazowych. Wartości tych różnic obliczono dla stacji EPN oraz ASG-EUPOS z rozwiązań dobowych. Dla większości z analizowanych stacji średnia kwadratowa otrzymanych odchyłek nie przekraczała 10 mm. Wartość ta oraz sam rozkład odchyłek nie zmieniał się znacząco przy różnych warunkach atmosfery. Na podstawie otrzymanych odchyłek fazowych przeanalizowano wpływ wielotorowości na tych stacjach. Modulacje wartości odchyłek na niskich kątach elewacji, których jednym ze źródeł jest efekt wielotorowości otrzymano zaledwie na kilku stacjach ASG-EUPOS. Taka sytuacja miała miejsce głównie dla stacji, których anteny zamontowane są na słupach. Wyniki pokazały, że podejście wykorzystujące analizę odchyłek liniowej kombinacji obserwacji fazowych jest dobrą metodą do oceny pracy stacji.
EN
A comparative study on analytical performance of a basic multi-commutated solenoid pump flow system (MPFS) and multi-commutated FIA system (MCFS) has been performed. Both flow systems utilised three-port solenoid valves acting as fluidic switches. The MCFS system was obtained by replacing a solenoid pump with a peristaltic pump, synchronized with valves, as a propelling unit. These two continuous flow strategies were applied to spectro-photometric determination of ammonium, nitrite, and phosphate in wastewater samples from urban wastewater treatment plant. Optimised peristaltic and solenoid pumped flow systems yielded similar results with respect to sensitivity', linear range . MPFS was. however, superior to MCFS in terms of day-to-day reproducibility (RSDs calculated for the slopes of 20 calibration curves obtained in different days were: , sample consumption (reduced twice for determination of ammonium and nitrite), and sample throughput . MPFS was advantageous with respect to versatility, possibility of miniaturisation, and increased simplicity due to reconfiguration of single-commutated elements without the need of physical reconfiguration of the flow manifold.
PL
Wykonano badania porównawcze sprawności analitycznej wielodrożnego przepływowego układu pompy solenoidowej (MPFS) i wielodrożnego układu wstrzykowej analizy przepływowej (MCFS). W obu układach zastosowano trójdrożne zawory solenoidowe działające jako przełączniki strumieniowe. Układ MCFS otrzymano przez zastąpienie pompy solenoidowej pompą perystaityczną, zsynchronizowaną/ zaworami, jako jednostką napędową. Te dwie strategie ciągłego przepływu zastosowano do spektrofotometrycznego oznaczania lonów amonowych, azotynów i fosforanów w próbkach ścieków z oczyszczalni miejskiej. Zoptymalizowane układy pompowe przepływu - perystaltyczny i solenoidowy dały podobne wyniki w odniesieniu do czułości, zakresu liniowości . MPFS był jednak lepszy niż MCFS w przypadku odtwarzalności z dnia na dzień (względne odchylenie standardowe obliczone dla 20 wykresów kalibracyjnych wyznaczonych w różnych dniach wynosiło: zużycia próbki (mniejszego dwukrotnie przy oznaczaniu NH4: i NO2 oraz liczby analiz (86 h-1 MPFS był również lepszy ze względu na wszechstronność, możliwość miniaturyzacji i większą prostotę - możliwość zamiany jcdnodrożnych elementów bez konieczności fizycznej rekonstrukcji przewodów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.