Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 25

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  wentylator osiowy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
In axial ventilation fans, the generation of a uniform flow velocity is desirable for better efficiency. To that end, different fan blade types have been developed to achieve better flow uniformity. This article aimed to characterize the flow distribution and its uniformity in four blade designs, namely constant chord, tapered blade, skewed blade, and tapered skewed blade, using Computational Fluid Dynamics (CFD). The study employs an iterative study where key study decisions are made as the study progresses. The study began with the selection of a blade profile for the study. A comparative study between the NACA seven-digit and four-digit series was conducted and for its higher flow throughput, the four-digit airfoil profile was selected. Next, with 30 and 40° Angle of Attack (AoA), the constant chord blade flow pattern is characterized. At 40° AoA flow disturbance and high-velocity spots were observed establishing the problem statement. Following that, three optimization strategies (tapering, skewing, and taper skewing) were applied in the design, and the flow pattern of each design was studied. Using a dispersion study a flow uniformity comparison between the models conducted. The property trade-off between three key performance indicators: efficiency, flow rate, and flow uniformity studied. The result shows an axial fan having a higher efficiency doesn't necessarily mean it has higher throughput whereas lower flow dispersion relates to the system's higher efficiency. Therefore, it can be concluded that seeking higher efficiency and flow uniformity in the design and development of axial fans comes with system throughput trade-off.
2
Content available Szybkie prototypowanie łopatek wentylatorów
PL
W artykule omówiono dotychczasowe prace rozwojowe, realizowane przez ITG KOMAG, w ramach projektu europejskiego INESI, których celem jest zwiększenie efektywności wentylatorów stosowanych w podziemiach kopalń. Cel ten może zostać osiągnięty przez polepszenie parametrów eksploatacyjnych wentylatora, poprzez modyfikację łopatek wirnika. Omówiono metodykę szybkiego prototypowania łopatek wentylatora, które zostaną przetestowane, z zastosowaniem druku 3D, przy wsparciu modelowaniem CFD. Przedstawione zostały również wyniki badań wentylatora przed i po modyfikacji łopatek.
EN
The article discusses previous development works carried out by ITG KOMAG within the framework of the European INESI project, whose aim is to increase the efficiency of fans used in underground mines. This goal can be achieved by improving the operating parameters of the fan, through the modification of the rotor blades. The methodology of rapid prototyping of fan blades which are going to be tested using 3D printing with the support of CFD modeling is discussed. The results of fan tests before and after modification of the blades are discussed.
PL
Przedstawienie innowacyjnej konstrukcji wentylatora osiowego dwustopniowego bez dyfuzora charakteryzującego się wysoką sprawnością i niskim hałasem.
EN
Presentation of the innovative construction of the two stage axial fan without diffuser. This fan is characterized by high efficiency and low noise.
4
Content available Strength Analysis of a Ducted Axial Fan Blade
EN
This paper presents a numerical strength analysis of a ducted axial fan blade. Ducted axial fans are a large group of fluid-flow machines. The analysis was designed to determine the causes of cyclic failures of a ventilation unit. The paper presents a reverse engineering approach to the mapping of the fan blade’s geometrical features. The geometrical features were mapped by triangulation from the scanning images produced by a 3D optical scanner. These were followed by simplifying assumptions on which the numerical calculations were based. The numerical calculations were carried out at the operating rotational speeds of the ducted axial fan’s rotor. The course of the numerical calculations is described, and their results are also presented herein. The results are represented on colour maps of stress distribution for selected structural elements of the fan blade. The stress distribution at a blade cross-section was compared to CT scans of the fractures of failed rotor blade airfoils. Final conclusions were developed which show that the design engineering process of fans should feature optimisation of the fan’s efficiency, including the strength and performance parameters, which should include the service life of the fan.
PL
W pracy przedstawiono numeryczną analizę wytrzymałościową łopaty osiowego wentylatora kanałowego. Wentylatory tego typu stanowią liczną grupę maszyn przepływowych. Wykonana analiza miała na celu określenie przyczyn powtarzających się cyklicznie awarii zespołu wentylacyjnego. Zaprezentowano sposób odwzorowania geometrii łopaty wentylatora poprzez zastosowanie metody inżynierii odwrotnej. Przy odwzorowywaniu geometrii wykorzystano skany otrzymane za pomocą skanera optycznego na zasadzie triangulacji. Następnie przedstawiono założenia upraszczające, na których oparte zostały obliczenia numeryczne. Obliczenia te przeprowadzono dla eksploatacyjnych prędkości obrotowych wirnika wentylatora. Z kolei opisano przebieg samych obliczeń numerycznych, a także przedstawiono uzyskane wyniki. Wyniki te zaprezentowano w postaci kolorowych map rozkładu naprężeń dla wybranych elementów konstrukcji łopaty. Rozkład naprężeń w przekroju poprzecznym łopaty porównano z tomograficznymi fotografiami przełomów zniszczonych piór łopat wirnika. Opracowano wnioski końcowe, z których wynika, że w procesie konstruowania wentylatorów powinna być wykonana optymalizacja nie tylko w obszarze jego sprawności, ale również w obszarze parametrów wytrzymałościowych i użytkowych, w tym między innymi trwałości eksploatacyjnej urządzenia.
5
Content available remote Numeryczna analiza charakterystyk wentylatora osiowego
PL
W artykule porównano podstawowe charakterystyki pracy wentylatora osiowego uzyskane metodą numeryczną i analityczną, stanowiące etap wstępnego projektowania wentylatora o zadanych osiągach. Takimi osiągami są charakterystyki przyrostu ciśnienia całkowitego, mocy oraz sprawności całkowitej w funkcji objętościowego natężenia przepływu. Przedstawione wyniki wykazywały istotne różnice ilościowe i jakościowe w przebiegu charakterystyk uzyskanych dwoma metodami. Potwierdzono przydatność metod numerycznych w odniesieniu do wstępnego projektu analitycznego.
EN
The paper presents an analysis and comparison of basic characteristics of axial fans, both analytically and numerically. Such characteristics are: the characteristics of the total pressure, power and total efficiency as a function of the volumetric flow rate. The presented results showed significant quantitative and qualitative differences in the characteristics obtained by two methods. The usefulness of numerical methods in relation to the results of the initial analytical project was confirmed.
EN
Purpose This study focuses on one of the key design aspects of mine ventilation fans, i.e. the selection of an appropriate aerofoil blade profile for the fan blades in order to enhance the energy efficiency of axial flow mine ventilation fans, using CFD simulations. Methods Computational simulations were performed on six selected typical aerofoil sections using CFD code ANSYS Fluent 6.3.26 at angles of attack varying from 0 to 21 at an interval of 3 and at Reynolds number Re = 3 × 106, and various aerody-namic parameters, viz. coefficients of lift (Cl) and drag (Cd) as a function of angle of attack (α) were determined to assess the efficiency of the aerofoils. Results The study revealed that the angle of attack has a significant effect on the lift and drag coefficients and stall condition oc-curred at α values of 12 and 15 in most of the aerofoils. Based on the criterion of higher lift to drag ratio (Cl/Cd), a blade profile was chosen as the most efficient one for mine ventilation fans. Practical implications This study forms a basis for selecting appropriate blade profiles for the axial flow fans used for ventilation in mining industry. Originality/ value The application of an appropriate aerofoil blade profile will impart energy efficiency to the mine ventilation fans and thereby result in energy saving in mine ventilation.
7
Content available remote Intensyfikacja chłodzenia generatorów dużej mocy
PL
W pracy opisano założenia projektowe wentylatorów osiowych ze zmodernizowanymi łopatkami wirnika oraz z tylnymi łopatkami kierowniczymi służącymi do chłodzenia generatora TWW-230. Podano bezwymiarowe charakterystyki przepływowe uzyskane podczas badań wykonanych w skali modelowej dla wirników zmodernizowanych z tylnymi łopatkami kierowniczymi oraz bez tych łopatek, jak również dla wirnika oryginalnego z tylnymi łopatkami kierowniczymi oraz bez tych łopatek. Zamieszczono rzeczywiste charakterystyki pracy tych wentylatorów, przeznaczonych do chłodzenia generatora typu TWW-230 o mocy 230MW wraz krzywymi oporów przepływu czynnika chłodzącego.
EN
In this paper brief foredesign for axial fans with modernized blades and back guide blades which cool TWW-230 generator have been described. Nondimensional and dimensional model fan characteristics for original rotor, modernized rotor with and without back guide blades in comparison to resistance curve of cooling medium flow have been presented.
PL
W artykule została przedstawiona metoda wyznaczania charakterystyki przepływu w tunelu aerodynamicznym za pomocą wentylatorów osiowych. Badanie zostało przeprowadzone po stronie tłoczącej za zwężką Witoszyńskiego przy użyciu termoanemometru elektronicznego. Oprócz analizy empirycznej wykonana została analiza komputerowa w celach porównawczych.
EN
Method of a flow characteristic’s determination in a wind tunnel with the help of axial-flow fans was presented in this paper. Research were carried out on the pressure side, behind the Witoszyński’s orifice using electronic hot-wire anemometer. Apart from the empirical analysis, also computer analysis was conducted with the comparative purpose.
EN
In this paper the scope of high power turbogenerators axial fans modernization was shown. On example of selected application in turbogenerator TWW-320-2Y3, thermal calculation results, verified on the basis of thermal measurements before and after the modernization, were presented. Effect of this type of fans modernization on the increase of turbogenerator nominal power was shown as well.
10
EN
In this paper new construction of axial fan impeller (with higher volume in comparison to original) forcing through cooling medium in high power generator TWW-230 has been presented. Designing processes, laboratory flow researches in model scale and practical implementation of new fan have been presented.
PL
W artykule zaprezentowano podstawowe zagadnienia związane z zużyciem energii elektrycznej przez agregaty chłodnicze. Często w wytycznych branżowych w projektach podawanych są różne dane elektryczne, które nie zawsze odpowiadają rzeczywistym warunkom pracy agregatu, bądź nie uwzględniają ich możliwych zmian w trakcie pracy systemu klimatyzacyjnego. Ponadto przedstawiono wzory związane z poborem mocy elektrycznej przez różne komponenty agregatów chłodniczych oraz możliwości zmniejszenia zużycia energii elektrycznej w obecnych konstrukcjach wytwornic wody ziębniczej.
PL
W instalacjach wentylacyjnych coraz częściej stosowane są przewody o niekołowych przekrojach poprzecznych, które umożliwiają efektywniejsze zagospodarowanie przestrzeni, a ponadto są zazwyczaj tańsze od przewodów kołowych. Zagadnienia dotyczące transportu gazów przy użyciu przewodów o przekrojach prostokątnych są w literaturze cytowane rzadko i dotyczą zazwyczaj uproszczonych modeli przepływu.
PL
Celem niniejszej pracy jest przeanalizowanie możliwości dostosowania prawa powinowactwa charakterystyk ciśnienia dla wentylatorów osiowych poprzez ustalenie jak najprostszej zależności funkcyjnej na wykładnik potęgi, którego wartośc standardowo jest równa 2.
19
Content available remote Analiza teoretyczna i eksperymentalna drgań łopat wentylatora osiowego
PL
W pracy opisano przykład praktycznego zastosowania analizy modalnej w diagnostyce i modernizacji wielkogabarytowych osiowych wentylatorów chłodni. Przeprowadzona na podstawie wyników tej analizy modernizacja 8 maszyn wyeliminowała często zdarzające się awarie, których skutkiem było na ogół całkowite zniszczenie układu łopatkowego wentylatora.
EN
An example of practical application of the modal analysis in diagnostics and modernisation of the large-scale structure of an axial fan in the cooling tower has been described. The results obtained and the modernisation of 8 machines carried out on the basis of these results have eliminated often failures of fans that always resulted in complete damage of the machine blading system.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.