Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  water teatment
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Removal of petroleum compounds from water in coagulation process
EN
Petroleum compounds represented by two types of oil emulsions of different initial concentration, prepared on the basis of diesel oil and mixol engine oil, were removed from water by volumetric coagulation method. In the process, the use was made of the following reagents: a powdery diatomite (fraction below 0.5 mm), such coagulants as aluminium sulphate and iron chloride as well as cationic flocculent. Due to coagulation performed with the use of coagulants only the oil content decreased considerably, provided that the coagulant dose was high (from 220 to 320 mg/dm3). In order to improve the coagulation efficiency and to reduce the doses of basic coagulants, a powdery diatomite of a remarkable sorptive capability was used. In the tests, coagulation by powdery diatomite used in various doses proved to be most efficient at the dose of 0.8 g/dm3 (for both types of emulsion and the coagulants applied). At this dose of diatomite, the most effective dose of each coagulant (Al 2(SO4)2 and FeCl3) reached 120 mg/dm3. In the removal of fuel oil (using both coagulants) and the mixol oil by means of Al2(SO4)2, a 100% reduction of oils was obtained.
PL
Związki ropopochodne usuwano z roztworów wodnych metodą koagulacji objętościowej. Z oleju napędowego i oleju silnikowego mixol sporządzono dwa rodzaje emulsji olejowych o różnych stężeniach początkowych. Do usunięcia związków ropopochodnych zastosowano diatomit pylisty (frakcja poniżej 0,5 mm), koagulanty (A12(S04)3ź18 H20 i FeCl3-6 H20) i flokulant (polielektrolit kationowy Zetag 50). W wyniku koagulacji przeprowadzonej z zastosowaniem samych koagulantów znacznie zredukowano zawartość olejów, ale jedynie wtedy, gdy dawki koagulantów były duże (od 220 do 320 mg/dm3). Aby poprawić efektywność usuwania niepożądanych związków i zmniejszyć dawki koagulantów podstawowych, do emulsji dodano diatomit pylisty, który łatwo sorbuje oleje. Badania wykazały, że optymalna dawka diatomitu dla obu rodzajów emulsji wynosiła 0,8 g/dm3, gdy każdy z obu koagulantów stosowano w dawce 120 mg/dm3. Dzięki tej procedurze uzyskano 100% usunięcia olejów.
2
Content available remote Mathematical model of PAC-adsorption and its application in water technology
EN
A mathematical model is presented, which describes the efficiency of organic matter removal by adsorption onto powdered activated carbon conducted both separately and simultaneously with the coagulation process. The model proposed describes the variations in the efficiency of organic fraction removal (measured in terms of dissolved organic carbon concentration) as a function of time, adsorbent dose and coagulant dose. Empirical formulae are derived to determine the value of the coefficient of adsorbate mass transfer rate. The formulae preserve their accuracy within the ranges used in the technological investigations performed for the purpose of the study.
PL
Zaprezentowano model matematyczny opisujący skuteczność usuwania związków organicznych metodą sorpcji na pylistym węglu aktywnym realizowaną jako wydzielony proces i symultanicznie z koagulacją. Zaproponowany model opisuje efektywność usuwania frakcji organicznych mierzonych stężeniem rozpuszczonego węgla organicznego, zmieniającą się w funkcji czasu, dawki adsorbentu i dawki koagulantu. Wyprowadzono wzory empiryczne pozwalające obliczyć wartość współczynnika szybkości przenoszenia masy adsorbatu, które zachowują swoją dokładność w zakresie przeprowadzonych badań technologicznych.
EN
The article presents the values of the optimal range of grain size diameter used in designing vertical flow sand filters. This is the crucial parameter since the filter bed grain size influences the concentration of pollutants in treated wastewater. Analyses were carried out on a column model installation consisting of five PCV columns with a 200 mm diameter. Sand and gravel having a d10 diameter from 0.28 to 4.28 mm were used as column filling. The research was carried out from March 2005 to February 2006. Wastewater was initially treated in a septic tank prior to reaching the model installation. Three physicochemical indexes were analyzed in wastewater: BOD5, CODCr and total suspended solids. The range in size of the d 10 diameter for each pollution index tested was defined as well as a single range of diameters for all three indexes. Based on the analysis of vertical flow sand filters, it was determined that the optimal d10 diameter of sand is from 0.28 to 1.65 mm.
PL
Podano zakres średnicy zastępczej, na jakim należy się opierać podczas projektowania filtrów piaskowych o przepływie pionowym. Jest to cenna informacja, gdyż średnica zastępcza złoża filtracyjnego w istotny sposób wpływa na stężenie ścieków oczyszczonych. Badania przeprowadzono, korzystając z modelu kolumnowego, który składał się z pięciu kolumn z PCV o średnicy 200 mm. Materiałem wypełniającym kolumny był piasek i drobny żwir o średnicy d10 od 0,28 do 4,28 mm. Badania przeprowadzono w okresie od marca 2005 r. do lutego 2006 r. Do modelu dopływały ścieki wstępnie oczyszczone w osadniku gnilnym. Badania fizykochemiczne objęły trzy wskaźniki zanieczyszczenia ścieków: BZT5, ChZTCr oraz zawiesinę ogólną. Określono zakres średnicy d10 uziarnienia złoża filtracyjnego dla każdego badanego wskaźnika zanieczyszczeń, a także jeden zakres średnic łącznie dla wszystkich trzech wskaźników. Na podstawie przeprowadzonej analizy danych stwierdzono, że do projektowania filtrów piaskowych o przepływie pionowym należy stosować piasek o średnicy d10 w przedziale od 0,28 do 1,65 mm.
PL
Rozwój procesów mikrofiltracji (MF) i ultrafiltracji (UF) upłynął na zmiany technologii uzdatniania wody naturalnej w stosunkowo krótkim czasie. Jednakże metody te nie są zbyt szeroko rozpowszechnione ze względu na trudności, które towarzyszą ich zastosowaniu, a szczególnie "fouling" spowodowany obecnością naturalnej substancji organicznej (NOM) w wodzie surowej. !u związku z tym proponuje się wprowadzenie wstępnej koagulacji przed filtracją membranową w celo nie tylko polepszenia usunięcia NOM, ale również zmniejszenia foulingu membran. Przedstawiono przegląd literatury na temat zastosowania hybrydowej metody koagulacja-UF/MF w uzdatnianiu wody w celu usunięcia NOM z wody oraz polepszenia wydajności filtracji membranowej.
EN
: The development of microfiltration (MF) and ultrafiltration (UF) membrane processes has significantly changed the natural water treatment industry in a relatively short time. However, they are not in wide-spread use because of some problems associated with their use, which include a low removal rate of and membrane fouling caused by NOMs (Natural Organic Matters) in the raw water. As a result, the addition of a coagulant as a pretreatment prior to membrane filtration has been proposed for the purpose of not only improving the removal of NOMs but reducing membrane fouling. The paper presents state-of-the an of the application of hybrid method coagulation- UF/MF in water treatment processes, for the removal of organics from water and also improving flux of membrane filtration unit.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.