Content available remote Design of continuous water heater hybrid solar and gas system
EN
Cooking water using LPG gas is practical and cleaner than using a firebox, but LPG gas is sourced from conventional energy so when the supply of petroleum mines runs out, LPG gas cannot be used anymore, while solar cells use heat from solar energy to meet various needs. very abundant and always there all the time. The purpose of this activity is to produce a continuous solar and gas hybrid system water heater, to know the working principle of the heater and to determine the performance of solar and gas cells in a solar and gas hybrid system continuous water heater. This activity method begins with the design design stage, followed by the manufacturing and assembling stages of the tool, performance testing and ends with the results of testing/data collection. From the test results, it was obtained the results of a continuous water heater hybrid system tool, a solar and gas hybrid system. The efficiency of solar panels is greatly influenced by the size of the intensity of solar radiation or weather. In testing the maximum solar panel efficiency tool is 16.68% with a solar radiation intensity of 1167 W/m2 and a minimum value of 7.28% with a solar radiation of 380 W /m2. The Hybrid system test is able to heat water up to 100 °C with varying efficiency depending on how long it has been used for the Heater and gas. But if you only use a heater, then the maximum water heating that can be achieved is 73.4 °C. This happens because by the time it reaches the water temperature, the power/voltage in the battery has reached its minimum limit (11 V) which is set on the LVD (Low Voltage Disconnect) so that the heater will turn off automatically and the gas (stove) will turn on automatically as well.
PL
Gotowanie wody na gazie LPG jest praktyczne i czystsze niż korzystanie z paleniska, ale gaz LPG jest pozyskiwany z konwencjonalnej energii, więc kiedy wyczerpią się zasoby kopalń ropy naftowej, gaz LPG nie może być już używany, podczas gdy ogniwa słoneczne wykorzystują ciepło z energii słonecznej do zaspokoić różne potrzeby. bardzo obfite i zawsze tam przez cały czas. Celem tego działania jest wyprodukowanie podgrzewacza wody w hybrydowym systemie solarnym i gazowym, poznanie zasady działania podgrzewacza oraz określenie wydajności ogniw słonecznych i gazowych w hybrydowym systemie solarnym i gazowym w ciągłym podgrzewaczu wody. Ta metoda działania zaczyna się od etapu projektowania projektu, następnie etapy wytwarzania i montażu narzędzia, testowania wydajności i kończy się na wynikach testów/gromadzeniu danych. Na podstawie wyników badań uzyskano wyniki działania narzędzia hybrydowego systemu ciągłego podgrzewacza wody, hybrydowego systemu słonecznego i gazowego. Na wydajność paneli fotowoltaicznych duży wpływ ma wielkość natężenia promieniowania słonecznego czy pogoda. W testach narzędzie maksymalnej sprawności paneli słonecznych wynosi 16,68% przy natężeniu promieniowania słonecznego 1167 W/m2 i minimalną wartość 7,28% przy promieniowaniu słonecznym 380 W/m2. Test systemu hybrydowego jest w stanie podgrzać wodę do 100°C z różną wydajnością w zależności od tego, jak długo był używany do podgrzewacza i gazu. Ale jeśli używasz tylko grzałki, maksymalna temperatura wody, jaką można osiągnąć, wynosi 73,4 °C. Dzieje się tak, ponieważ zanim woda osiągnie temperaturę, moc/napięcie w akumulatorze osiągnęło swój minimalny limit (11 V), który jest ustawiony na LVD (Low Voltage Disconnect), dzięki czemu podgrzewacz wyłączy się automatycznie, a gaz (piec) również włączy się automatycznie.
PL
W procesach podgrzewu c.w.u. do tej pory wykorzystywana była woda grzewcza o wysokiej temperaturze, rzędu 80 °C. Taka temperatura gwarantowała dobrą wymianę ciepła oraz stosunkowo krótki czas podgrzewu. W przypadku pomp ciepła [PC] nie dysponujemy tak wysoką temperaturą. Poza tym częsta eksploatacja pompy ciepła na wysokich parametrach jest zabójcza dla sprężarki, która jest sercem pompy i jej najdroższym elementem. Jakie zatem mamy rozwiązania podgrzewu c.w.u. w przypadku pomp ciepła? - przyjrzyjmy się temu zagadnieniu.
EN
The present work involved an extensive outdoor performance testing program of a solar water heating system that consists of four evacuated tube solar collectors incorporating four wickless heat pipes integrated to a storage tank. Tests were conducted under the weather conditions of Baghdad, Iraq. The heat pipes were of 22 mm diameter, 1800 mm evaporator length and 200 mm condenser length. Three heat pipe working fluids were employed, ethanol, methanol, and acetone at an inventory of 50% by volume of the heat pipe evaporator sections. The system was tested outdoors with various load conditions. Results showed that the system performance was not sensitive to the type of heat pipe working fluid employed here. Improved overall efficiency of the solar system was obtained with hot water withdrawal (load conditions) by 14%. A theoretical analysis was formulated for the solar system performance using an energy balance based iterative electrical analogy formulation to compare the experimental temperature behavior and energy output with theoretical predictions. Good agreement of 8% was obtained between theoretical and experimental values.
4
Content available remote Hot water (PWH) systems from hygienic and energetic point of view
EN
People often keep the temperature in PWH tanks set Iow to save electricity and prevent scalding. To kill off the legionnaires bacteria is recommended temporarily turning up the temperature to above 60°C, especially if people prone to the infection are using the water. Large water heaters frequently contain cool zones near the base where cold water enters and scale and sediments accumulate. Design water systems designed to recirculate water and minimize dead legs will reduce stagnation. If potential for scalding exist, appropriate, fail - safe scald protection equipment should be employed. Point of-use water heaters can eliminate stagnation of hot water in frequently used lines. Proper insulation can help maintain distribution and delivery temperatures.
PL
W celu oszczędności energii i zapobieganiu sparzaniu ludzie zwykle utrzymują temperaturę w zbiornikach wodnych na niskim poziomie. Aby zabić bakterie Legionnela zaleca się okresowe podnoszenie temperatury do ponad 60°C, szczególnie gdy ludzie skłonni do zarażenia używają wody z takiego zbiornika. Duże podgrzewacze wody często zawierają chłodne strefy w pobliżu podstawy, gdzie wpływa zimna woda i gromadzi się kamień i osady. Zaprojektowany system wodny zapewniający recyrkulację wody i minimalizujący martwe odcinki redukuje zastoje. W przypadku istnienia niebezpieczeństwa sparzania powinno być zainstalowane odporne na uszkodzenia wyposażenie przeciw sparzaniu. Miejscowe grzejniki wody pozwalają wyeliminować zastoje ciepłej wody w często używanych odcinkach. Właściwa izolacja pomaga utrzymać rozdział i dostarczenie temperatury.
6
Content available remote Segmentacja rynku na przykładzie firmy 'Biawar'
PL
W obecnej dobie, w dobie różnicowania się gustów i preferencji konsumentów oraz indywidualizacji potrzeb, segmentacja rynku staje się wręcz nieodzowna. Pierwsza część niniejszego artykułu przedstawia teoretyczne zagadnienia związane z tym procesem oraz wynikające z tego procesu korzyści. Druga część ukazuje właściwą segmentację rynku ogrzewaczy wody produkowanych przez białostocką firmę 'Biawar' oraz możli-wości wykorzystania wyników badań.
EN
Nowadays, when customers differentiate their likings and preferences and their needs become more and more individual, market segmentation seems to be really necessary. The first part of this article presents theoretical issues connected with this process, and profits which can be the results of it. While, the second part of the article shows a real segmentation of the market of water heaters produced by 'Biawar' - Białystok Company and the posibilities for using the results of these studies.
7
Content available remote Stan ciepłownictwa w Oświęcimiu
PL
Ciepło na potrzeby miasta Oświęcimia jest wytwarzane przez kocioł wodny WP-70 o mocy 81,4 MW. Zapotrzebowanie dla warunków obliczeniowych -20°C wynosi 95,26 MW. Istnieje niedobór około 13,9 MW w stosunku do warunków obliczeniowych. Woda sieciowa 150/80°C przesyłana jest do miasta magistralami: Północ i Południe. Magistralą Południe przesyłanych jest około 45 MW. System dystrybucji ciepła przedstawia się następująco: sieć wody grzewczej 150/80°C - 40,4 km, sieć międzyblokowa 90/70°C -40,5 km, instalacje c.o, około 240 km, liczba wymiennikowni ciepła 43, indywidualne węzły wymiennikowe 348,węzty połączenia bezpośredniego wysokich parametrów 10 szt., 2 przepompownie wody gorącej, 95 komór ciepłowniczych. Liczba budynków wielorodzinnych wynosi 241, budynków jednorodzinnych 405. Powierzchnia ogrzewana 726 714 m2, w tym mieszkalna 526 012 m2. Roczne zużycie ciepła wynosi 600 000 GJ. Obecnie z budżetu miasta realizowane są następujące inwestycje ciepłownicze: uciepłownienie Kolonii A na os. Chemików, uciepłownienie Osiedla im. Rotmistrza Pileckiego, budowa rurociągów ciepłowniczych 200 mm do os. Błonie, budowa głównych rurociągów rozdzielczych w rejonie ul. Chopina i Piłsudskiego, uciepłownienie rejonu ul. Garbarskiej.
EN
Oświęcim heat supplies come from the water boiler WP-70 81.4 MW. The demand for the calculational conditions of -20°C is 95.26 MW. About 13.9 MW deficiency can be noted with regard to the calculational conditions. Network water 150/80°C is transported through the North and South main routes. About 45 MW are sent through the South main route. Heat is distributed according to the following pattern: heating water system 150/80°C - 40.4 km, interblock network 90/70°C - 40.5 km, central heating instalments about 240 km, 43 heat exchangers, 384 individual exchange centres, 10 centres of direct connection (high parameters), 2 pumping centres for hot water, 95 heat chambers. The number of blocks of flats - 241, detached houses - 405, the heated area -726,714 m2, in that 526,012 m2 of residence area. Yearly heat demand is equal to 600,000 GJ. Presently a part of the municipal budget has been allotted to the following investments: heating of Kolonia A at the Chemików housing estate, heating of the Rotmistrz Pilecki housing estate, build of heat pipelines (200 mm) to the Błonie housing estate, build of dispatch pipelines in the region of Chopina Str. and Piłsudskiego Str., heating of Garbarska Str. region.