1
Content available Experimental Study of Air Lift Pump Delivery Rate
EN
This paper presents analysis of results of investigations of flow rate of sand (Qs) and water (Qw) in an air lift pump. The investigations were performed on an air lift pump test rig, constructed in a laboratory on a scale of 1:1. The paper describes the construction and working principle of this air lift pump test rig and presents a methodology of derivation of empirical formulas for calculation of sand and water flow rate. A comparative analysis of the values of the sand and water flow rate obtained in direct measurements with analogical values of flow rate calculated with use of the derived empirical formulas was carried out. The research scope encompassed the derivation of the aforementioned empirical formulas in the PVC air lift pump with the internal diameter of the discharge pipe d = 0.03 m by the fixed sand-water mix delivery heads H: 0.40 m, 0.80 m, 1.20 m. To derive the empirical formulas for calculation of the sand and water flow rate, dimensional analysis and multiple regression was applied. In the air lift pump being tested, the water and sand flow rate felt along with the rise in the delivery head and the water flow rate was higher than the sand flow rate. Air pressure in such devices cannot be lower than 110 kPa and cannot exceed 150 kPa as for higher values of air pressure the sand and water flow rate starts to fall. The values of the sand and water flow rate calculated with use of the derived formulas coincide very well with the values determined from the direct measurements.
PL
W artykule przedstawiono analizę wyników badań natężenia przepływu piasku (Qs) i wody (Qw) w podnośniku powietrznym. Badania wykonywano na wybudowanym w laboratorium w skali 1:1 stanowisku do badania podnośnika powietrznego. W artykule przedstawiono budowę i zasadę działania stanowiska badawczego oraz omówiono metodykę wyznaczenia empirycznych wzorów do obliczania natężenia przepływu piasku i wody. Przeprowadzono analizę porównawczą wartości natężenia przepływu piasku i wody wyznaczonych z bezpośrednich pomiarów z wartościami obliczonymi za pomocą wyznaczonych empirycznych wzorów. Zakres badań obejmował wyprowadzenie wzorów do obliczania natężenia przepływu piasku i wody w podnośniku powietrznym z tworzywa sztucznego PVC o średnicy wewnętrznej rurociągu tłocznego d = 0,03 m, przy zadanej wysokości podnoszenia mieszaniny piasku i wody H: 0,40 m, 0,80 m, 1,20 m. Do wyznaczenia empirycznych wzorów do obliczania natężenia przepływu piasku i wody zastosowano analizę wymiarową i metodę regresji wielokrotnej. W badanej konstrukcji podnośnika powietrznego wraz ze wzrostem wysokości podnoszenia mieszaniny piasku i wody, natężenie przepływu piasku i wody malało, a wartości natężenia przepływu wody były większe w stosunku do wartości natężenia przepływu piasku. W badanym urządzeniu ciśnienie powietrza nie może być mniejsze niż 110 kPa i nie powinno przekraczać 150 kPa, ponieważ przy wyższych ciśnieniach powietrza natężenie przepływu piasku i wody zaczynało spadać. Wartości natężenia przepływu piasku i wody obliczone za pomocą wyprowadzonych wzorów, bardzo dobrze pokrywały się z wartościami wyznaczonymi z bezpośrednich pomiarów.
EN
Analysis of results from a study on sand (Qz) and water (Qw) flow rate in an air lift pump was presented as well as the methodology of empirical formulas derivation to calculate those parameters. A comparative analysis of the values of sand and water flow rate from direct measurements and the calculated values was carried out. The scope of laboratory research encompassed derivation of the aforementioned empirical formulas to calculate water and sand flow rate for the plastic air lift pump with internal diameter of the delivery pipe d = 0.04 m, at fixed sand-water mix delivery heads of 0.40 m, 0.80 m and 1.20 m. Dimensional analysis and multiple regression were applied to derive the formulas. It was established that the water and sand flow rate decreased along with the increase of the delivery head, and the values of water flow rate were smaller than those of the sand flow rate. It was demonstrated that the air pressure in such devices cannot be lower than 110 kPa or exceed 175 kPa as at higher pressure values the sand and water flow rate started to fall. The values of sand and water flow rates calculated by the derived formulas coincided very well with the values determined by direct measurements using the 1:1 scale laboratory model.
PL
Przedstawiono analizę wyników badań strumienia objętości piasku (Qz) i wody (Qw) w podnośniku powietrznym oraz omówiono metody wyznaczania wzorów empirycznych do obliczania wartości tych parametrów. Przeprowadzono analizę porównawczą wartości strumienia objętości piasku i wody wyznaczonych w bezpośrednich pomiarach z wartościami obliczonymi za pomocą wzorów empirycznych. Zakres badań laboratoryjnych obejmował wyprowadzenie wzorów do obliczania wartości strumienia objętości piasku i wody w powietrznym podnośniku z tworzywa sztucznego o średnicy wewnętrznej rurociągu tłocznego d=0,04 m, przy zadanych wysokościach podnoszenia mieszaniny piasku i wody równych 0,40 m, 0,80 m i 1,20 m. Do wyznaczenia wzorów empirycznych do obliczania wartości strumienia objętości piasku i wody zastosowano analizę wymiarową i metodę regresji wielokrotnej. W przypadku badanej konstrukcji podnośnika powietrznego stwierdzono, że wraz ze wzrostem wysokości podnoszenia mieszaniny piasku i wody strumień objętości piasku i wody malał, a wartości strumienia objętości wody były mniejsze od wartości strumienia objętości piasku. Wykazano, że w urządzeniu tego typu ciśnienie powietrza nie może być mniejsze niż 110 kPa i nie powinno przekraczać 175 kPa, ponieważ przy wyższych wartościach ciśnienia powietrza strumień objętości piasku i wody zaczynał maleć. Wartości strumienia objętości piasku i wody obliczone za pomocą wyprowadzonych wzorów bardzo dobrze pokrywały się (korelowały?) z wartościami wyznaczonymi w pomiarach bezpośrednich na modelu laboratoryjnym w skali 1:1.
PL
Wodne pompy ciepła są w Polsce najrzadziej stosowanymi pompami ciepła. Jest to spowodowane wysokimi kosztami inwestycyjnymi oraz skomplikowanymi uwarunkowaniami prawnymi. Cechują się one jednak wysokim współczynnikiem efektywności energetycznej w stosunku do innych rozwiązań. Prace takiego urządzenia rozpatrywać można w dwóch stanach, konwekcji swobodnej, kiedy mamy do czynienia ze zbiornikami wodnymi w których występują jedynie konwekcyjne ruchy wody spowodowane różnicą gęstości (stacjonarne zbiorniki wodne takie jak jeziora, stawy, przydomowe baseny) oraz konwekcji wymuszonej, kiedy istnieje ukierunkowany przepływ wody w zbiorniku (rzeki, morza, ścieki kanalizacyjne). Wydajność oraz efektywność energetyczna wodnej pompy ciepła w tych dwóch stanach znacznie się różni. Jak wynika z analiz teoretycznych oraz badań wstępnych przeprowadzonych na modelu wodnej pompie ciepła znajdującej się na Wydziale Techniki Morskiej i Transportu, wymuszony ruch wody na powierzchni parowacza wpływa korzystnie na charakterystyki energetyczne urządzenia. Badania wstępne w warunkach konwekcji wymuszonej prowadzone były w okresie letnim oraz zimowym, a poprzedzone zostały dokładnymi badaniami w warunkach konwekcji swobodniej w okresie całego roku. Obecnie trwają analizy oraz przygotowania do prowadzenia właściwych badań kształtowania się efektywności energetycznej wodnej pompy ciepła w warunkach konwekcji wymuszonej w okresie zimowym (w niskiej temperaturze wody, tw = 1-4°C
EN
Water source heat pumps are the least frequently used heat pumps in Poland. It follows high investment costs and the increasingly complex legal conditions. However, they are characterized by a high rate of energy efficiency compared to other solutions. The work of such a device may be viewed in two states, natural convection, when we are dealing with water reservoirs in which there are only a convective movement of water caused by different density (stationary water reservoirs such as lakes, ponds, backyard swimming pools) and forced convection, when there is a directed flow of water in the reservoir (rivers, sea, sewage drainage). Performance and energy efficiency water source heat pumps in these two states varies greatly. As follows from theoretical analysis and preliminary studies conducted on a model water source heat pump located at the Faculty of Maritime Technology and Transport, forced movement of water on the surface of the evaporator has a beneficial effect on the energy performance of the device. Preliminary studies in conditions of forced convection were conducted during the summer and winter, and were preceded by accurate research in the natural convection conditions throughout the year. Currently, analysis, and preparations are being made to conduct proper research development of the energy efficiency water source heat pump in conditions of forced convection for the winter (in the low water temperature, tw = 1-4°C).
EN
Water pump control methods are presented for the district heating system supplying an industrial heat user. The analysis aimed at determining optimum operating conditions for the system of pumps. The study focused on control parameters of the pumps installed at the heating substation delivering the heated water to the end-user. The chosen method consisted of throttling control of the pump using a control valve in the discharge header. The values of characteristic parameters and control characteristics of the pumps were used to evaluate the performance of the said pump system.
5
Content available remote Zagospodarowanie borowiny pozabiegowej w uzdrowiskach polskich
EN
This paper describes commonly mud bath treatments performed in the spa facilities in Poland and the requirements for equipment and plumbing in the treatment rooms. It also presents the steps of the disposal of the mud bath, with the main focus on the management of post-treatment mud. The article discusses the health resorts problems with the management of post-treatment mud. The article describes the legal situation with the development of post-treatment mud in connection with the entry of the new regulations. It also given the perspective of further legal changes.
PL
W niniejszej pracy opisano zabiegi borowinowe wykonywane powszechnie w zakładach uzdrowiskowych w Polsce oraz wymagania dotyczące wyposażenia i instalacji wodno-kanalizacyjnych w pomieszczeniach zabiegowych. Przedstawiono etapy gospodarki borowinowej, przy czym zwrócono szczególną uwagę na zagospodarowanie borowiny pozabiegowej. Omówiono problemy gospodarowania borowiną pozabiegową, z którymi borykają się polskie uzdrowiska, sytuację prawną związaną z zagospodarowaniem borowiny pozabiegowej w związku z wejściem w życie nowych rozporządzeń oraz podano perspektywy kolejnych zmian prawnych.
6
Content available remote Wymiarowanie instalacji wodociągowej w zakładach przyrodoleczniczych
PL
W artykule podano warunki jakie musi spełniać obszar, któremu nadawany jest status uzdrowiska, omówiono potencjał uzdrowisk polskich, przedstawiono krótką charakterystykę oddziałów i zabiegów oferowanych w zakładach przyrodoleczniczych i pry-watnych hotelach SPA, przy czym zwrócono szczególną uwagę na aspekt instalacji wodociągowych tych oddziałów. Omówiono charakterystykę rozbioru wody w tego typu obiektach, wskaza¬no zależność do określania obliczeniowego natężenia przepływu wody oraz określono wartości natężeń poboru wody przez poszczególne odbiorniki wody w zakładzie przyrodoleczniczym. Podano zalecane prędkości przepływu wody w instalacji wód leczniczych.
EN
The article specifies the conditions which must be met by an area which is assigned a status of a health resort. It also presents an overview of Polish health resorts, their potential and the range of treatment offered by natural medicine centres and private SPA hotels, with the main focus on their water supply systems. The article discusses characteristics of water consumption in this type of buildings, indicates the formula to calculate the flow rate and determines the intensity of water consumption by particular devices in a natural medicine centre. Moreover, the article describes the recommended flow rate in the system supplying the healing water.
PL
W ramach niniejszej pracy wykonano badania zmierzające do określenia odżelaziania z udziałem wybranych mas aktywnych. Dodatkowo, w celu dokładniejszej interpretacji uzyskanych wyników badań procesu filtracji, przeprowadzono analizę sitową zastosowanych mas oraz określono porowatość złóż filtracyjnych. Do badań przyjęto cztery dostępne na rynku masy aktywne, czyli Birm, G-1, Purolite MZ-10 oraz Defeman. W skład Birmu wchodzi ditlenek manganu, amorficzna i krystaliczna krzemionka oraz składniki wiążące. Purolite MZ-10 jest naturalnym zeolitem, składającym się głównie ze związków SiO2 i Al2O3. Masy G-1 oraz Defeman to materiały naturalne, składające się (podobnie jak Birm) między innymi z ditlenku manganu. Badania dynamiczne były prowadzone po okresie wpracowania się złóż, zaś w przypadku masy Purolite MZ-10 (zgodnie z zaleceniem producenta) złoże było poddawane regeneracji roztworem KMnO.
EN
In the paper the results of research on manganese and iron removal process are presented. The study was carried out on Laboratory-scale columns experiments filters with variable water flow rate: 5, 7.5, 10, 12, 15 and 18 m/h and four types of materials were studied. The results of the research allowed comparing and estimating the effect of various water flow rate for effectiveness of tested filter materials. Among activated filtrating masses G-1, Purolite MZ-10 and Bir showed satisfying effects. However, activated mass Defeman shows worsen effectiveness in manganese and iron removal with higher filtrating speed. Research result shows, that selecting particular filter bed and setting up the parameters of filtering process should be done basing on the qualitative and quantitive of treated water and preliminary research done in laboratory scale or semi-technical scale.
PL
Badaniom poddano dwustopniowe filtry pospieszne (antracytowo-piaskowe i węglowe) w Stacji Uzdatniania Wody w Gruszczynie (zaopatrującej w wodę Poznań i Swarzędz), wyposażone w dwa rodzaje nowoczesnych systemów drenażowych TRITON i SE-LOP. Podczas modernizacji stacji filtrów dokonano pomiaru strat hydraulicznych powodowanych przez oba systemy drenażowe przy różnej intensywności płukania złóż filtracyjnych wodą oraz porównawczo - przez same systemy drenażowe (bez złóż filtracyjnych). Wyznaczone doświadczalnie rzeczywiste straty hydrauliczne na badanych drenażach porównano z wartościami obliczeniowymi opartymi na danych podawanych przez ich producentów. Porównanie wysokości strat ciśnienia podawanych przez producenta oraz wartości zmierzonych doświadczalnie na stacji filtrów wykazało, że straty rzeczywiste na samym drenażu SE-LOP były większe o prawie 50%, natomiast obliczeniowe i pomierzone straty ciśnienia w warstwie złoża filtracyjnego były porównywalne.
EN
The objects under study were two-stage rapid filters (anthracite-sand and active carbon) operated by the Water Treatment Plant in Gruszczyn, which supplies municipal water to the cities of Poznan and Swarzedz. The filters were fitted with two types of advanced drainage systems, TRITON and SE-LOP. During modernization of the water treatment plant, measurements were conducted to determine the hydraulic losses caused by the two drainage systems at a varying rate of filter backwash water flow, and (for comparison) the hydraulic losses caused by the drainage systems alone. Actual hydraulic losses obtained with the drainage systems tested were compared with those calculated based on the manufacturers' specifications. Analysis of the hydraulic head losses specified by the manufacturers and those measured in the filter plant has produced the following finding: the actual hydraulic head losses caused by the SE-LOP drainage system alone are by approximately 50% higher compared to the calculated values, whereas the hydraulic head losses measured in the filter beds are comparable with the calculated ones.