Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  volume resistance
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Modern industry is looking for new functional materials with the same or better functional properties while reducing the burden on the natural environment. Innovative materials such as composites, which are a combination of components with different and complementary properties and the appropriate technology of their production meets these expectations. The preliminary studies carried out indicate the possibility of using the method of producing a metal / polymer composite for the construction panels and casings covering the electromagnetic field.
PL
Współczesny przemysł poszukuje nowych materiałów funkcjonalnych o takich samych lub lepszych właściwościach użytkowych przy jednoczesnym zmniejszeniu obciążenia środowiska naturalnego. Innowacyjne materiały, takie jak kompozyty, które są połączeniem komponentów o różnych i uzupełniających się właściwościach oraz odpowiednia technologia ich wytwarzania, spełniają te oczekiwania. Przeprowadzone badania wstępne wskazują na możliwość zastosowania opracowanej przez wytwarzania kompozytu metal/polimer na płyty konstrukcyjne i obudowy pokrywające pole elektromagnetyczne.
PL
Artykuł prezentuje wybrane metody badań własności rezystancyjnych powłok antyelektrostatycznych. Omówiono ich przydatność w warunkach przemysłowych. Wyszczególniono wady i zalety zaprezentowanych metod. Zaproponowano system pomiarowo-diagnostyczny, który pozwalałby na wykorzystanie potencjału pomiarowego omówionych metod przy jednoczesnej minimalizacji ich wad. Wskazano potrzebę oszacowania oraz kontroli rezystancji skrośnej i powierzchniowej warstw antyelektrostatycznych jako wykorzystywaną w celach normalizacji oraz spełnienia parametrów jakościowych i ekonomicznych.
EN
The paper presents selected research methods resistive properties of anti-static layers. Typical applications of anti-static layers, and the threat posed by static discharge are described. Discusses the usefulness in industrial conditions, and detailed the advantages and disadvantages presented methods. In chapter 3 discusses the method suggested in the Polish Standards [1], fig. 2; four-probe method, fig. 3; van der Pauw'a method [6] fig. 4; comparative method, with a capacity of capacitor [4], and eddy currents [8]. As the main disadvantage of these methods are given the possibility of measuring only in specialized laboratories in the prepared samples. In section 3.6 the author suggests the creation of control and measurement systems to enable testing under operating conditions the object coated anti-static layers. More than a system would enable to carry out measurements on samples of irregular shape. The aim of the development of that system is to simplify the measurement techniques for antistatic coatings, while maintaining the required accuracy, making possible the appropriate selection of coating components and simultaneously lowering its prices.
3
Content available remote Measurements of the Volume and Surface Resistance of Textile Materials
EN
A lot of standards describe resistance and resistivity measurement methods appropriate for a particular material or product. In the case of textile materials, some evolution has occurred in both the defnitions and measurement techniques in the sphere of resistance and resistivity measurements. Some standards outline a two-electrode measurement system for surface resistance. The sole volume nature of conduction current is assumed to appear in textile materials. This assumption leads to a specifc relation between the volume Rv2 and "surface" resistances Rs (Rv1). In this study, it was also shown that in the case of standard electrodes, the parameter (Rv1/Rv2) h2 (where h is the sample thickness) should be constant. The value of this parameter, determined experimentally, was found to be constant for fabrics with a volume resistivity that changed over three orders of magnitude. However, the parameter value was much lower in comparison to that predicted theoretically. The phenomenon observed was explained by the infuence of additional contact resistance appearing between the sample surface and the rigid electrodes, as well as by the anisotropy of resistivity.
4
Content available Szynoprzewody w izolacji stałej
PL
W referacie zaprezentowano wybrane wyniki pomiarów różnych parametrów prototypów szynoprzewodów z izolacją stałą. Prezentowane poniżej szynoprzewody różnią się od istniejących już na rynku z uziemioną obudową (ekranem). Jest to trudny do zaprojektowania i skonstruowania tor prądowy m.in. ze względu na wysoki poziom wyładowań niezupełnych już przy niedużych napięciach.
EN
Chosen measuring results related to partial discharges and volume resistance of specific busbars are presented in the article. These busbars differ from existent one at the market from earthing enclosure (screen). Such a current path is difficult to design and construct among other things by reason of high level of partial discharges even under relatively low voltages. The next problem consists in tendency to growth of volume resistance of busbar insulation depending on the length of the path. Propositions how these faults can be limited are considered at the end of the article.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.