In direct torque vector control systems, voltage source inverter is described in discrete mode as a source of constant amplitude voltage sources with strictly controlled direction, time duration and limited sample frequency. The dynamic state of the inverter is discrete both in time and quantity. In this paper, therefore, the basic characteristics of stator flux space vector will be analysed in such a control concept for two different types of space vector modulation (SVM) techniques one is full block space vector modulation and second is called pulse edge space vector modulation.
PL
W układach bezpośredniego sterowania wektorami momentu obrotowego, falownik źródła napięcia jest opisany w trybie dyskretnym jako źródło stałych źródeł napięcia o amplitudzie ze ściśle kontrolowaną polaryzacją, czasem trwania i ograniczoną częstotliwością próbkowania. Stan dynamiczny falownika opisywany jest w sposób dyskretny zarówno pod względem czasu jak i wartości. W przedstawionym artykule została przeanalizowana podstawowa charakterystyka wektora przestrzennego strumienia stojana w koncepcji sterowania dla dwóch różnych sposobów modulacji wektora przestrzennego (SVM). Jedna jest modulacją wektora przestrzennego obszaru pracy blokowej, a druga jest nazywana dyskretną modulacją wektora przestrzennego.
PL
W artykule opisano zagadnieniami związane z Modularnym Przekształtnikiem Wielopoziomowym wykonanym z wykorzystaniem tranzystorów HEMT z azotku galu (GaN). Przedstawiony został projekt obwodu silnoprądowego urządzenia oraz wymagania stawiane układowi sterowania. W publikacji przedstawiono również opis elektronicznej platformy sterującej dla przekształtnika.
EN
The article describes issues related to the Modular Multilevel Converter made with the use of gallium nitride (GaN) HEMT transistors. The design of the power circuit of the device and the requirements for the control system are presented. The publication also presents the description of the electronic control platform designed to control the converter.
EN
Synchronous self-excited generators still are and probably will be the most popular 3-phase alternators installed in inland power stations so onboard of seagoing ships. Because of fuel savings and environmental restrictions Diesel, dual-fuel and gas propulsion engines for alternators of wide-range varying revolutions drives are increasingly used. There must be efficient way of creating 3-phase voltages of desired constant parameters ensured when generator produces variable amplitudes and frequencies of voltages because of changing rotational speed. As the control method modified field oriented control widely used with squirrel cage induction machines was chosen. This control method involves decoupling of currents and control voltages to flux and torque components and keeping them in optimal (orthogonal) condition. In order to obtain proper excitation and operation of such generator several factors have to be taken into account. Nonlinear dependence of voltage generated from rotational speed of self-excited synchronous generator is one of the factors that affects initial excitation process thus specific control method while generator startup. Theoretical background of synchronous generator excitation and voltage source inverter adopted FOC control method along with experimental results obtained in laboratory test bench of 5,5 kW generator and conclusions were presented.
EN
In this paper an extensive comparative performance study is carried out between No-load and load condition of an open loop model of a Brushless Direct Current (BLDC) Motor drive fed from a two-level voltage source inverter (VSI) under 120-degree conduction mode, using simulations in a MATLAB based software environment. BLDC motors are currently growing in popularity and replacing the brush motor in many applications, as they can be used in both low and high-speed vehicle systems and also in servo drives. The high reliability, torque to inertia ratio, high efficiency, high power density, ease of control and mainly the brushless operation make BLDC motors superior to others. It has a permanent magnet as a rotor with a balanced 3-phase armature in its stator. The armature winding is driven by a power electronics inverter which is switched in synchronism with the rotor position, sensed by an optical encoder or a Hall Effect sensor. It is found that torque ripple can be minimized by tuning the value of rotor position, no load condition and trapezoidal armature phase current. The different performance parameters for no-load and load condition of the BLDC motor such as phase voltages, phase currents, speed, electromagnetic torque, d and q axis current and rotor position etc. are determined in MATLAB environment.
5
Content available remote Input impedance of multi-drive traction vehicle
EN
The tractions vehicle's input impedance Zin is an important parameter from the point of view of compatibility in electric traction system. The article presents a simulation analysis and comparison of input impedance of two types of traction drive systems: a drive system with a single inverter and a drive system with two parallel inverters cooperating with one input filter. The analysis was carried out for 50 Hz impedance, which acceptable minimum level is defined in the relevant regulations.
PL
Impedancja wejściowa elektrycznego pojazdu trakcyjnego Zin jest ważnym parametrem z punktu widzenia kompatybilności w trakcji elektrycznej. W artykule przedstawiono symulacyjną analizę i porównanie impedancji wejściowej dwóch trakcyjnych układów napędowych: układu z pojedynczym falownikiem oraz układu z dwoma falownikami współpracującym z jednym filtrem wejściowym. Analizę przeprowadzono dla impedancji 50 Hz, której dopuszczalny minimalny poziom jest określony w odpowiednich przepisach.
EN
Voltage source inverters in UPS systems should have restricted distortions in case of the standard loads defined by EN-62040-3 standard. Only control systems measuring not only the output voltage but additionally the inverter output filter coil current and the load current are able to decrease Total Harmonic Distortions of the output voltage for the static nonlinear load and to decrease the overshoot and the settling time of the output voltage for the dynamic load. The design of most of the control systems requires the knowledge of the inverter model which is based on its output LC filter. The inductance and the serial resistance of the coil should be measured in the operating point of the inverter. The paper presents the VSI with the multiple input Passivity Based Control designed using the measurements of the output filter parameters. The experimental verification of the theoretical considerations in the breadboard inverter model is presented.
PL
Falowniki napięcia stosowane w systemach UPS powinny mieć ograniczone zniekształcenia napięcia wyjściowego zgodnie z normą EN-62040-3. Tylko systemy sterowania, które mierzą nie tylko napięcie wyjściowe ale także dodatkowo prąd dławika filtra wyjściowego i prąd obciążenia są zdolne zmniejszyć współczynnik zniekształceń harmonicznych napięcia wyjściowego dla statycznego nieliniowego obciążenia oraz zmniejszyć przeregulowanie i czas dojścia do stanu ustalonego napięcia wyjściowego dla dynamicznego obciążenia. Projekt większości systemów sterowania wymaga znajomości modelu falownika, który opiera się na wyjściowym filtrze LC. Indukcyjność i szeregowa rezystancja dławika powinny być mierzone w punkcie pracy falownika. Artykuł przedstawia falownik napięcia z wielowejściowym systemem sterowania typu „Passivity Based Control” zaprojektowanym w oparciu o pomiary parametrów filtra wyjściowego. Przedstawiono eksperymentalną weryfikację rozważań teoretycznych z wykorzystaniem laboratoryjnego modelu falownika.
PL
Łagodne przełączanie tranzystorów w falownikach napięcia wymaga najczęściej stosowania kondensatorów i dławików indukcyjnych. W proponowanym układzie łagodnego przełączania, w odróżnieniu od istniejących rozwiązań, nie występuje niebezpieczeństwo udarowego rozładowania kondensatora przez tranzystor główny falownika oraz nie ma ryzyka przerwania prądu dławika, co grozi uszkodzeniem tranzystorów. Przedstawiono zasady pracy układu, wytyczne doboru elementów oraz wyniki badań laboratoryjnych.
EN
Soft switching systems in voltage source inverters usually require the use of additional transistors, capacitors and induction chokes. Contrary to existing solutions, in the proposed system there is no danger of abrupt discharge of the capacitors through the conductive transistor. Moreover, there is no risk of interruption of the induction choke current which usually causes damage of transistors. The principles of the system operation, rules of components selection, and laboratory test results are presented in this paper.
8
Content available remote A novel soft switching system for three-phase voltage source inverter
EN
Soft switching systems in three-phase voltage source inverters usually require the use of additional elements, such as transistors, capacitors and inductors. Contrary to the existing solutions, in the proposed soft switching system, the danger of an abrupt discharge of the capacitors through the conductive transistor does not occur. Moreover, there is no risk of interruption of the inductor current, which usually causes damage to the transistors. In the paper principles of the system operation are described in detail and rules of component selection are presented. Laboratory tests were performed for different operating conditions. The test results have confirmed the operation correctness of the three-phase voltage source inverter with the proposed soft switching system.
PL
Łagodne przełączanie tranzystorów w falownikach napięcia wymaga najczęściej stosowania dodatkowych elementów, takich jak tranzystory, kondensatory i dławiki indukcyjne. W odróżnieniu od istniejących rozwiązań, w proponowanym układzie łagodnego przełączania nie występuje niebezpieczeństwo udarowego rozładowania kondensatora przez tranzystor główny falownika oraz nie ma ryzyka przerwania prądu dławika, co grozi uszkodzeniem tranzystorów. Przedstawiono zasady pracy układu, wytyczne doboru elementów. Badania laboratoryjne przeprowadzono dla różnych warunków pracy. Wyniki badań potwierdziły poprawność działania trójfazowego falownika z proponowanym układem łagodnego przełączania tranzystorów.
EN
An enhancement to the previously developed repetitive neurocontroller (RNC) is discussed and investigated in the paper. Originally, the time-base generator (TBG) has been used to produce the only input signal for the neural approximator. The resulting search space makes the dynamic optimization problem (DOP) of shaping the control signal solvable with the help of a function approximator such as the feed-forward neural network (FFNN). The plant under consideration, i.e. a constant-amplitude constant-frequency voltage-source inverter (CACF VSI) with an output LC filter, is assumed to be equipped with the disturbance load current sensor to enable implementation of the disturbance feed-forward (pDFF) path as a part of the non-repetitive subsystem acting in the along the pass p-direction. An investigation has been undertaken to explore potential benefits of using this signal also as an additional input for the RNC to augment the approximation space and potentially enhance the convergence rate of the real-time search process. It is numerically demonstrated in the paper that the disturbance feed-forward path active in the pass-to-pass k-direction (kDFF) improves the dynamics of the repetitive part as well indeed.
10
EN
A power distribution system with distributed generations can operate as a microgrid under specific conditions. A microgrid can be operated under grid-connected and islanded modes seamlessly without disrupting the loads within the microgrid. This study analyzes the intelligent control of a microgrid with a pulse-width modulation-controlled voltage source inverter. Switching patterns are generated through a fuzzy proportional-integral (PI) controller. This study aims to develop a fuzzy-PI controller and compare its performance with that of a PI controller in controlling the voltage and frequency of a microgrid under disturbances in a Matlab/Simulink environment. Results show that the fuzzy-PI controller has higher capability, precision, and robustness than the PI controller in quickly restoring and stabilizing the microgrid. A simulation experiment is also performed to verify the greater validity and effectiveness of the microgrid equipped with the fuzzy-PI controller than with the PI controller. The developed fuzzy-PI controller can reduce the total harmonic distortion by 0.46%.
PL
W artykule analizowano inteligentne sterowanie mikrosiecią z wykorzystaniem przekształtnika sterowanego metodą modulacji szerokości impulsu. Jako sterownik wykorzystano proporcjonalno całkujący układ z logika rozmytą. Zbadano pracę układu w sieci z zakłóceniami. Stwierdzono znaczące przewagi kontrolera pracującego z logika rozmytą w porównaniu do układów konwencjonalnvch.
11
Content available remote Switching losses in three-phase voltage source inverters
EN
The efficiency of three-phase voltage source inverters depends mainly on power losses that occur in semi-conductor elements. Total losses in these elements are a sum of conduction losses and switching losses. The switching losses are dependent on the supply voltage, load current, operating frequency and on the dynamic parameters of the switching elements; these losses can be limited with the use of soft switching methods. This paper discusses the switching loss dependence on the above mentioned factors. An analysis was carried out on power losses in voltage source inverters which generate the output voltage in the form of a rectangular wave and losses in these inverters operating with pulse width modulation. A comparison of switching losses was performed for two voltage source inverters with different nominal power ratings.
PL
Sprawność trójfazowch falowników napięcia zależy głównie od strat mocy występujących w elementach półprzewodnikowych. Straty w tych elementach są sumą strat przewodzenia i strat przełączania. Straty przełączania zależą od napięcia zasilania, prądu odbiornika, częstotliwości pracy oraz od parametrów dynamicznych tranzystorów IGBT; straty te mogą być ograniczone przez zastosowanie układów wspomagających przełączanie elementów. W artykule omówiono zależność strat przełączania od wymienionych czynników. Przeprowadzono analizę strat w falowniku generującym na wyjściu napięcie w postaci fali prostokątnej oraz analizę strat przełączania w falowniku pracującym z modulacją szerokości impulsów. Porównania strat przełączania dokonano dla dwóch falowników napięcia o różnych mocach znamionowych.
12
Content available remote Zmienność topologii LCL i mała dobroć Q w układzie VSI-LCL
PL
Artykuł przedstawia niekorzystne warunki i zjawiska przy których występują ograniczenia mocy wyjściowej i zakresu sterowania układów VSI-LC(C)L. Analizie poddano przypadek pracy z małą dobrocią Q układu oraz zjawisko zmiany topologii obwodu rezonansowego.
EN
The paper presents conditions and phenomena resulting in power and control limitations of induction heating VSI-LC(C)L system. The case of resonant load low quality factor Q has been considered. Also the resonant load topology changes phenomena is shown and investigated.
PL
W artykule przedstawiono główne zagadnienia związane z projektowaniem, budową i badaniami trójfazowego falownika napięcia przy użyciu tranzystorów Z-FET z węglika krzemu charakteryzującego się wysoką sprawnością (>98%) i wysoką częstotliwością przełączeń (do 150kHz). Omówiono dobór warunków pracy tranzystorów, pracujących bez zewnętrznych diod zwrotnych, w kontekście miniaturyzacji układu. Przedstawiono przyjętą metodykę projektowania dla układu o mocy znamionowej S = 6 kVA. Ponadto artykuł zawiera wyniki badań laboratoryjnych falownika o cechach prototypu, który na wyjściu filtru LC wytwarza napięcie przemienne 3x400V RMS.
EN
This paper presents the main issues related to the design, construction and tests of a three-phase voltage source inverter with Silicon Carbide MOSFETs, which is characterized by a high efficiency (>98%) and high switching frequency (up to 150kHz). The selection of the operation conditions of transistors, which are operating without external anti-parallel diodes, in the context of miniaturization of the converter was discussed and the design methodology on the example of converter with rated power S = 6 kVA was presented. Furthermore, the paper shows the results of laboratory tests of the prototype with the output voltages 3x400V RMS.
EN
This paper presents the performance evaluation of two control techniques, namely Dead Beat Control (DBC) and Hysteresis Band Control (HBC), in a three phase Shunt Active Power Filter (SAPF). The choice and implementation of the current controllers is vital for the achievement of a satisfactory filtering performance. Although these techniques have been applied previously to design SAPF for single phase distorted power system signals, in this paper we extend them to three phase distorted power system signals. In order to test the effectiveness of these two controllers, extensive simulations were conducted using MATLAB/simulink. The results obtained show the superiority of the hysteresis current controller over the dead beat controller in terms of exhibiting fast transient response and computational simplicity. These results are valid with real-time Opal-RT results.
EN
Algorithms of space-vector-based synchronized pulsewidth modulation (PWM) have been applied for control of dual-inverter fed open-end winding induction motor drives supplied by two isolated dc-sources with non-equal voltages. Results of modeling and simulation of these systems proved the fact, that techniques of synchronized PWM provide continuous phase voltage symmetry (quarter-wave symmetry, or half-wave symmetry) for any ratios (integral or fractional) between the switching and fundamental frequencies of dual-inverter systems on the base of either standard inverters or neutral-point-clamped inverters, and also for any ratios between voltages of two dc-sources of the system.
PL
W artykule przedstawiono możliwość sterowania napędem silnika indukcyjnego zasilanego za pośrednictwem dwóch izolowanych źródeł napięcia stałego o nierównych napięciach. Do tego celu wykorzystano podwójny przekształtnik bazujący na algorytmie synchronizowanej modulacji szerokości impulsu PWM.
EN
This paper presents a space vector pulse width modulation (SVPWM) control for a five-level five-phase cascaded H-bridge multilevel inverter (CHMLI) for photovoltaic (PV) systems. The maximum power point tracking (MPPT) is solved by fuzzy logic controller (FLC) and it is capable of extracting maximum power from PV array connected to each DC link voltage level. The fuzzy MPPT is integrated with the inverter so that a DC-DC converter is not needed and the output shows accurate and fast response. This is done to achieve high dynamic performance with low total harmonic distortion (THD). The simulation results are compared with sinusoidal pulse width modulation (SPWM) controlled CHMLI and diode clamped multilevel inverter (DCMLI) in terms of THD. The results prove the viability and verify the effectiveness and accuracy of the proposed system.
PL
W artykule zaprezentowano pięciopoziomowy, pięciofazowy kaskadowy przekształtnik CHMLI z modulacja szerokości impulsu SVPPWM przystosowany do pracy w układach fotowoltaicznych. Do śledzenia maksimum mocy zastosowano sterownik fuzzy logic FLC. Otrzymano dobre właściwości dynamiczne i mały poziom zniekształceń.
17
Content available remote FPGA Based Implementation of Amplitude Modulated Triangular Carrier PWM
EN
The amplitude modulated triangular carrier pulse width modulation method (AMTCPWM) is a natural sampled PWM method which can extend the linearity of the sinusoidal PWM (SPWM) to full range of the pulse dropping region and increase the dynamic range of the SPWM control. Any submission in the PWM theory with a specific performance target is mandatorily requires either a reference or a carrier modification. This paper presents a reprogrammable architecture to implement the AMTCPWM with perfect reproduction capability. The architecture is implemented using Spartan 6 family device LX45 using Modelsim 6.3 and Xilinx 13.2i.
PL
Metoda modulacji amplitudowej fali nośnej trójkątnej AMTCPWM umożliwia rozszerzenie możliwości klasycznej metody sinusoidalnej PWM SPWM. W pracy zaprezentowano wykorzystanie układów FPGA.
18
Content available remote Wysokoczęstotliwościowy przekształtnik z tranzystorami SiC JFET
PL
W referacie przedstawiono konstrukcję oraz wyniki badań trójfazowego falownika napięcia zbudowanego z wykorzystaniem diod Schottky oraz tranzystorów JFET z węglika krzemu (SiC). Znacznie krótsze czasy przełączeń tych elementów w porównaniu z tranzystorami IGBT i diodami na bazie krzemu (Si) umożliwiają pracę układu z częstotliwością 100 kHz i wyższą. Duża stromość narastania napięcia rzędu dziesiątek kV/žs powoduje problemy EMC oraz EMI. Wysokoczęstotliwościowe przekształtniki z tranzystorami SiC JFET dają nowe możliwości regulacji układów z silnikami wysokoobrotowymi (100 tys. obr./min.), co potwierdzają przedstawione wyniki badań symulacyjnych i eksperymentalnych generacji napięcia o częstotliwości podstawowej harmonicznej 1500Hz.
EN
The paper presents design and testing of a three-phase voltage inverter built with application of silicon carbide (SiC) Schottky diodes and SiC JFET transistors. Shorter switching times of these elements in comparison with IGBTs and diodes based on a silicone (Si) makes it possible operation with a frequency of 100 kHz and higher. High rate of change of power devices voltages, up to several dozen of kV/žs causes EMC and EMI problems. High-frequency converters with SiC JFET transistors gives new capabilities in control of high-speed electric motors.
19
Content available remote VSI PWM inverter feed induction machine using Volts per Hertz Control Scheme
PL
Opisano wykorzystanie przekształtnika napięciowego VSI do sterowania trójfazowego silnika AC. Sterowanie odbywa się z wykorzystaniem techniki PWM. Kontrolowany jest strumień w szczelinie powietrznej w celu utrzymania stałego momentu.
EN
In this article a voltage source inverter (VSI) is developed for use in pulse width modulation (PWM) speed control systems for three phase ac motors. This system uses the technique of sine-wave modulation and employs a purpose-designed L.S.I circuit for PMW generation. A constant torque control scheme is employed in order to keep the air-gap flux and consequently the motor output torque constant. Steady state and transient behavior performance of our system is investigated. Experimental results are also being presented.
20
Content available remote VS PWM inverter feed induction machine using Volts per Hertz Control Scheme
PL
Opracowano przekształtnikowe źródło napięcia VSI zastosowane do sterowania trójfazowym silnikiem z wykorzystaniem modulacji PWM. Zbadano pracę w stanie ustalonym oraz w stanach przejściowych.
EN
In this article a voltage source inverter (V.S.I) is developed for use in pulse width modulation (P.W.M) speed control systems for three phase a.c motors. This system uses the technique of sine-wave modulation and employs a purpose-designed L.S.I circuit for PMW generation. A constant torque control scheme is employed in order to keep the air-gap flux and consequently the motor output torque constant. Steady state and transient behavior performance of our system is investigated. Experimental results are also being presented.