Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  voltage sag
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper, a voltage control system for a PMSM motor based on the QZSDMC converter is proposed, which allows operation in both buck and boost modes as a possible method to make the drive resistant to power grid voltage sags. The authors presented a method for measuring and transforming the output voltage from QZS, enabling the use of a PI controller to control the voltage supplied to the DMC converter. The publication includes simulation and experimental studies comparing the operation of a PMSM motor powered by DMC and the proposed QZSDMC with voltage control. Simulation studies confirm the drive with QZSDMC resistance to voltage sags up to 80% of the rated value. Experimental studies demonstrate the correct operation of PMSM even with a power grid voltage amplitude equal to 40% of the rated value.
EN
Since electrical drives have become an integral element of any industrial sector, power quality difficulties have been well expected, and delivering genuine quality of the same has proven to be a difficult challenge. Since power quality relies on load side non-linearity and high semiconductor technology consumption, it is a serious concern. The efficiency of the drive segment employed in the sector is increasingly becoming a topic of discussion in today’s market. Numerous reviews of available literature have found problems with the load side as well as with electrical drive proficiency, as a result of the issues listed above. A high level of power quality vulnerability is simply too much. Even the most advanced technology has its limits when it comes to drive operation. Research on the grid-side quality issues of electrical drives is the focus of this article. After field testing of grid power quality, each parametric analysis is performed to identify crucial parameters that can cause industrial drives to fail. Based on this discovery, a machine learning strategy was developed and an artificial intelligence technique was proposed to administer the fault deterrent prediction algorithm. An accurate forecast of anomalous behavior on the grid side ensures safe and dependable grid operation such that shutdown or failure probability is minimized to a greater extent by the results. Additional information gleaned from historical data will prove useful to equipment manufacturers in the future, providing a solution to this problem.
3
Content available remote Voltage sag mitigation using direct converter based DVR without error signal
EN
Dynamic voltage restorer is considered to be one of the best device to compensate voltage sag and swell. Recently the DVRs based on direct converters are very popular and works are getting published for various topologies and modulating techniques to explore the efficiency and worth of the same. In this paper, the direct converter is realized using only two bidirectional switches, in order to mitigate voltage sag. The voltage required to compensate the voltage sag is taken from the same phase where the voltage sag has occurred. The direct converter is connected between the line in which the voltage sag has occurred and the series transformer. In the conventional PWM generation technique, the supply voltage is measured and compared with the reference voltage in order to find out the voltage sag and the error voltage signal. This error signal will be compared with the carrier to generate the PWM pulses. Though already papers have been published to mitigate voltage sag using direct converter, in this paper, as one of the efforts to show the flexibility of the direct converter based DVR, the voltage sag is mitigated without measuring the supply voltage and without generating the error signals, since the power required to mitigate the sag is taken from the phase where it occurred. Ordinary PWM technique is used to control the bidirectional switches. In this proposed methodology the DVR is able to compensate 22% of voltage sag. The simulation is carried out in Matlab Simulink and the results are presented for verification
PL
Dynamiczny restorer napięcia jest uważany za jedno z najlepszych urządzeń do kompensacji zapadów i wzrostów napięcia. Ostatnio bardzo popularne są rejestratory DVR oparte na konwerterach bezpośrednich i publikowane są prace dla różnych topologii i technik modulacji w celu zbadania ich wydajności i wartości. W niniejszym artykule przekształtnik bezpośredni jest realizowany przy użyciu tylko dwóch dwukierunkowych przełączników, w celu złagodzenia zapadu napięcia. Napięcie wymagane do skompensowania zapadu napięcia jest pobierane z tej samej fazy, w której wystąpił zapad napięcia. Przetwornik bezpośredni jest podłączony między linią, w której wystąpiło zapad napięcia, a transformatorem szeregowym. W konwencjonalnej technice generowania PWM napięcie zasilania jest mierzone i porównywane z napięciem odniesienia w celu określenia zapadu napięcia i sygnału błędu napięcia. Ten sygnał błędu zostanie porównany z nośnikiem w celu wygenerowania impulsów PWM. Chociaż opublikowano już artykuły mające na celu złagodzenie zapadu napięcia za pomocą bezpośredniego konwertera, w tym artykule, jako jeden z wysiłków mających na celu pokazanie elastyczności rejestratora opartego na bezpośrednim konwerterze, zapad napięcia jest łagodzony bez pomiaru napięcia zasilania i bez generowania sygnałów błędu , ponieważ moc wymagana do złagodzenia zwisu jest pobierana z fazy, w której wystąpił. Do sterowania przełącznikami dwukierunkowymi wykorzystywana jest zwykła technika PWM.
EN
The aim of this paper is to explain the control algorithm very clearly and precisely to achieve maximum voltage sag compensation of 52% and infinite quantity of voltage swell using direct converter based DVR. The proposed DVR topology has a single phase matrix converter (SPMC), series transformer and LC filter. If the duty cycle of the PWM is digitally computed by measuring the available voltage at the supply and the percentage of voltage sag, it is possible to mitigate 52% of voltage sag and infinite quantity of voltage swell with the THD less than 1%. Matlab Simulation results are presented for validating the analysis.
PL
Celem artykułu jest precyzyjne wyjaśnienie algorytmu sterowania w celu uzyskania maksymalnej kompensacji zapadu napięcia wynoszącej 52% i wzrostu napięcia przy użyciu rejestratora DVR z bezpośrednim przetwornikiem. Proponowana topologia DVR ma jednofazowy konwerter macierzy (SPMC), transformator szeregowy i filtr LC. Jeżeli cykl pracy PWM jest obliczany cyfrowo poprzez pomiar dostępnego napięcia na zasilaniu i procentu zapadu napięcia, możliwe jest złagodzenie 52% zapadu napięcia i wielkości wzrostu napięcia przy THD mniejszym niż 1%. Wyniki Matlab Simulation są prezentowane w celu walidacji analizy.
EN
For voltage-source-converter based high-voltage-direct-current (VSC-HVDC)transmission systems, fault ride-through (FRT) capability is a very important grid requirement in order to enhance its operational availability under an alternating current (AC) gridfault condition. Voltage sags during a short-circuit fault in power transmission lines can leadto fluctuations in the direct current (DC) link voltage of converter systems, and may inducereversed power flow and even trip a VSC-HVDC transmission system. A practical methodis developed in this paper for investigating FRT capability of VSC-HVDC transmissionsystem characteristics during a voltage sag event using experimental results from Smart Grid Laboratory. Symmetrical and asymmetrical voltage sag events with different remaining voltages are applied to an AC grid that lasts with a variable duration. The experimental waveforms of the two converter systems are recorded and analyzed in order to evaluate theFRT capability of VSC-HVDC transmission systems.
PL
W artykule przedstawiono opis układu bezprzerwowego zasilania średniego napięcia zawierającego: zasobnik superkondensatorowy, wielopoziomowy przekształtnik DC/AC i szybki łącznik próżniowy. Opracowany system może służyć jako zabezpieczenie wydzielonej sieci energetycznej średniego napięcia przed zanikami lub zapadami. Opisano ideę działania, realizację wybranych bloków układu oraz wyniki badań laboratoryjnych.
EN
This article describes the uninterruptible power supply in a medium voltage setup comprising a supercapacitor storage device, DC/AC multi-level inverter and fast vacuum switch. Described system can secure islanded grid of medium voltage against interrupions or sags. An idea of functioning, implementation of selected components and laboratory results was shown.
PL
W pracy zaprezentowane zostanie stanowisko laboratoryjne przeznaczone do badania elektrowni wiatrowej z maszyną indukcyjną dwustronnie zasilaną w stanach awaryjnych sieci zasilającej. Odpowiednio połączone moduły stanowiska dają użytkownikowi możliwość wykonywania badań symulujących zachowania rzeczywistej elektrowni wiatrowej podczas zakłóceń w sieci zasilającej. W skrócie opisany zostanie moduł symulujący zapady napięcia i zwarcia w sieci zasilającej. Przedstawione zostaną wyniki badań ukazujące reakcję części mechanicznej turbiny wiatrowej przy 100% zapadach napięcia oraz utrzymanie pracy turbiny przy rożnych rodzajach zwarć.
EN
A laboratory model introduced for the wind power plant with double fed asynchronous generator investigations in times of grid emergency is proposed in article. An user thanks to adequate modules connections may investigate wind power plant operations during grid disturbances. A module to simulate grid voltage falls and short-circuit will be shortly presented. The investigations results showing: the mechanical parts of wind turbine reactions during 100% grid voltage falls and turbine behavior during different kind of short-circuits will be presented.
EN
The necessity of developing and implementation of the guaranteed power supply system using distributed generation on the base of alternative and renewable energy sources is proved in conditions of responsible technological processes. The theoretical and experimental researches were made in raw mineral enterprises, which have a great amount of responsible technological consumers. The permitted duration of power supply interruption for responsible consumers of continuous technological processes of raw mineral industry is determined. The effectiveness of distributed generation using for guaranteed power supply mode is shown. The reasonability of solar, wind and followed oil gas energy applying in role of power sources for distributed generation is also proved in the paper. The basic variants of guaranteed power supply system structure are described and offered in the paper for all kind of industry and technique, especially for responsible digital control systems and telecommunications.
9
Content available remote Impact of Protective Relays on Voltage Sag Index
EN
This paper provides the probability-assessment analysis on the characteristic value of the voltage sag by using Monte Carlo stochastic modelling method to stimulate the randomness of the short circuit fault. Furthermore, this article simulates the influence of the protection devices on the voltage sag to ensure the authenticity and the referential reliability. A system with inverse-time protection devices equipped on each lines which could coordinate together are designed to cut off the short-circuit fault. The voltage sag of the designed system is evaluated by the pre-and post system average RMS variation frequency index, and the voltage sag index is compared with the ITIC curves.The simulation results demonstrated that the inverse-curve relay protection equipments are well-coordinated, and the severity and the range of the voltage sag are influenced by the cooperation of the equipped inverse time protection devices.
PL
W artykule przedstawiono metodę szacowania prawdopodobieństwa wystąpienia zapadu napięcia na podstawie analizy jego charakterystycznych parametrów zamodelowanych metodą Monte Carlo. Ponad to, w celu weryfikacji skuteczności, dokonano symulacji wpływu urządzeń ochronnych na zapady napięcia. Zaprojektowano także system z urządzeniami umożliwiającymi odizolowanie zwarcia w obwodzie od reszty sieci. Wyznaczono współczynnik częstotliwościowy zmienności wartości średniej RMS zapadów napięcia w proponowanym układzie, który następnie porównano z krzywymi ITIC. Przeprowadzone badania symulacyjne potwierdziły skuteczność i szybkość działania systemu.
10
EN
This paper deals with the development of an enhanced controller for investigation of dynamic voltage restorer (DVR) compensation capabilities. Two levels, 24-pulse DVR is modeled with a new control scheme to control the switch signal in the voltage sourced converter. A study on voltage sag compensation capability, harmonic elimination, effect of phase shift on DVR sizing, influence of induction motor load and effect of capacitor value on DVR performance have been investigated. Results proved that the DVR is a suitable device for maximum power quality (PQ) compensation. Thus, the developed model and controller will be useful for further power quality studies in a distribution system.
PL
Opisano ulepszony sterownik system dynamicznego odzyskiwania napięcia DVR. Przeanalizowano przypadki możliwości kompensacji zapadów napięcia, eliminacji harmonicznych oraz wpływ indukcyjności obciążenia. Symulacje potwierdziły przydatność układu w systemach poprawy jakości energii.
EN
The output of power stations varies widely with the diverse operating modes in which the vessels integrated power system (IPS) works. Taking two parallel generators with different capacity for example, there are four possible protection schemes set for both the bus breaker and the main breakers of generators. The results show that the setting value used in each of four cases cannot offer appropriate protection for the normal operation of the system. For this reason, a solution is proposed, that is, the time-current principle in combination with the detection of voltage sag.
PL
Przy dwóch połączonych równolegle generatorach o różnej pojemności trzeba używać cztery układy zabezpieczające dla dwóch łączników szynowych i głównych łączników generatorów. W artykule zaproponowano nowe rozwiązanie układu zabezpieczającego bazujące na analizie czas-prąd i detekcji zapadów napięcia. (Układy zabezpieczenia generatorów równoległych o różnej pojemności dołączonych do zintegrowanego systemu energetycznego)
EN
In this paper, a new method for improving reliability level of distribution systems is presented by employing optimal placement of DSTATCOM. The binary version of the Gravitational Search algorithm (BGSA) is used to solve the DSTATCOM optimal placement problem. The simulation results show that the proposed method is efficient and feasible for improving the system reliability level by reducing load outages and momentary interruptions.
PL
Przedstawiono nową metodę poprawy niezawodności system dystrybucji energii dzięki optymalizacji DSTATCOM. Optymalne położenie DSTATCOM było określane na podstawie algorytmu BGSA. Uzyskano [poprawę dzięki dedukcji przerw w obciążeniu i chwilowych zaników.
13
Content available remote Generation of voltage references using Multilayer Feed Forward Neural Network
EN
Among the dynamic voltage restorer (DVR) objectives, the protection of sensitive loads against voltage swell/sag voltage, as well as correction of unbalanced problems. The DVR acts as a voltage source, which is connected in series with a sensitive load and controlled to generate the required compensation voltages. Many researches were presented in literature to identify the voltage disturbance; one of them is Synchronous Reference Frame (SRF) method. This paper provides a DVR with identification method based on artificial neural network - the (MLFFN) Multilayer Feed Forward Neural Network. To investigate this novel method performance, it is confronted with the conventional (SRF) method. All of the studies have been carried out using the simulation with the MATLAB Simulink Power System Toolbox. The results of simulation study of new DVR detecting method presented in this paper are found quite satisfactory to eliminate the voltage disturbance from utility voltage.
PL
Przedstawiono dynamiczny układ przywracania napięcia DVR jako zabezpieczenie przeciw zapadom napięcia. Układ działa jako źródło napięcia połączone w szereg z obciążeniem. W artykule opisano metodę identyfikacji wykorzystującą sztuczne sieci neuronowe. Przedstawiono też symulacje systemu.
14
Content available remote Analysis of AC Contactor Model during Voltage Sag with Point-in-Wave of Initiation
EN
This paper presents the analysis of AC contactor model, its ride through capability and behaviour during voltage sag with point-in-wave of initiation using PSCAD/EMTDC simulation software. The ride-through capability curve is used to identify the sensitivity level in the AC contactor failure area. AC contactor simulation model were supplied with various type of voltage sag with point-in-wave of initiation. Simulation results are also validated with the ride through capability curve of the experimental results.
PL
Przedstawiono analizę pracy stycznika AC podczas możliwych zapadów napięcia przy wykorzystaniu symulacji z PSCAD/EMTDC. Modelowano różne stany zapadów jak też i różne pozycje stycznika.
EN
This article presents a novel method to locate the voltage sag source based on directional overcurrent (DOC) relay information. In this method the source of voltage sag is located by using the variation of magnitude of measured current positive-sequence component during sag and presag conditions and the sign of its phase-angle jump. The performance of the proposed method is compared with distance relay (DR) and phase change in sequence current (PCSC) methods by using PSCAD/EMTDC on a simulated case study. The results show the good and unique performance of the novel method in cases where only currents are recorded.
PL
W artykule zaprezentowano nową metodę lokalizacji źródła zapadu napięcia bazującej na informacji o kierunkowym przeciążeniu prądowym. Źródło zapadu napięcia jest lokalizowane na podstawie pomiaru amplitudy i fazy prądu w czasie zapadu i przed zapadem. Porównano metodę z z dotychczas stosowanymi metodami DR i PCSC.
EN
Faults in the power system are major cause of voltage sag. Voltage sag in the power system due to fault can be symmetrical or unsymmetrical. For sensitive loads it is necessary to estimate how many times in year the voltage at their terminal will experience sag to avoid tripping of operation. Several stochastic methods for estimation of number of sags are developed in recent years. In different methods of sag prediction there is need to do lengthy programming or calculations. Here PSCAD/EMTDC software package is used to estimate number of sag with uniform distribution of faults along the lines.
EN
The problem of control of a wind power generator in cases when voltage sags occur in the electric power system is presented in the paper. Double fed machine (DFM) used as the generator in the wind power plant is considered. The stator of the DFM is connected to the grid and the cascade of power electronic inverters supplies the rotor. When the voltage drop or sag occurs in the power network, controllers of the cascade of power electronic inverters can work incorrectly. In this case, the wind power generators are disconnected in present solutions. Results of simulation of the system with models of the double fed machine, the grid transformer and the inverters are presented in the paper. To control the generated power the structure based on a multiscalar model of the DFM was used. Proposed solution of control makes it possible to keep the power plant in the power system during required time.
first rewind previous Strona / 1 next fast forward last