EN
The achievement of voltage stability is among the most prominent challenges faced by grid operators. In the past, generator excitation regulation was the only method available, for restoring the voltage to its rated values. However, rapid developments in the areas of power grids and power stations, has led to the need of a new technique, for controlling the voltage level, and maintaining the system in the voltage stability band. Onload tap changing (OLTC) is currently among the most widely employed methods, for improving the stability of the power system voltage. OLTC restores the voltage value, whether the disturbance occurs on its primary or secondary side. While a minor disturbance is easily overcome by OLTC, its capacity for restoring the voltage level, during a significant disturbance, is dependent on its ratings and setting values. The failure of the OLTC transformer, to restore the voltage value within a short period, may result in a collapse of the voltage system, when the transformer proceeds with reverse action. A simulation model in MATLAB Simulink shows the effect of OLTC on the Nineveh power grid.
PL
Osiągnięcie stabilności napięcia jest jednym z najważniejszych wyzwań, przed jakimi stają operatorzy sieci. W przeszłości regulacja wzbudzenia generatora była jedyną dostępną metodą przywracania napięcia do wartości znamionowych. Jednak szybki rozwój w obszarach sieci elektroenergetycznych i elektrowni spowodował konieczność opracowania nowej techniki kontroli poziomu napięcia i utrzymywania systemu w paśmie stabilności napięcia. Zmiana zaczepów pod obciążeniem (OLTC) jest obecnie jedną z najczęściej stosowanych metod poprawy stabilności napięcia systemu elektroenergetycznego. PPZ przywraca wartość napięcia, niezależnie od tego, czy zakłócenie występuje po stronie pierwotnej czy wtórnej. Podczas gdy małe zakłócenie jest łatwo przezwyciężane przez PPZ, jego zdolność do przywracania poziomu napięcia podczas znacznego zakłócenia zależy od jego wartości znamionowych i nastawczych. Awaria transformatora PPZ przywracająca w krótkim czasie wartość napięcia może skutkować załamaniem się układu napięciowego, gdy transformator działa odwrotnie.Model symulacyjny w MATLAB Simulink pokazuje wpływ PPZ na sieć energetyczną Niniwy.
EN
The problem of voltage collapse is a major issue in the operation of the current power system, especially when the penetration of wind turbines into the system continues to increase. The intermittency of the wind turbine has an impact on the stability of the system voltage. Fast Voltage Stability Index (FVSI) is used as a parameter for the condition of the system with the phenomenon of voltage collapse. This study aims to observe and predict the value of the Line stability index using Optimally Pruned Extreme Learning Machine (OP-ELM). The test case in this study is the South Sulawesi-Indonesia Electric Power System, with a total wind turbine penetration of 142 MW. From the simulation, it can be seen that OPELM can do forecasting very well with an error rate of 0.0886%.
PL
Problem załamania napięcia jest poważnym problemem w funkcjonowaniu obecnego systemu elektroenergetycznego, zwłaszcza gdy penetracja turbin wiatrowych do systemu nadal wzrasta. Przerywalność turbiny wiatrowej ma wpływ na stabilność napięcia systemu. Wskaźnik stabilności szybkiego napięcia (FVSI) jest używany jako parametr stanu systemu ze zjawiskiem załamania napięcia. Niniejsze badanie ma na celu obserwowanie i przewidywanie wartości wskaźnika stabilności linii przy użyciu maszyny OP-ELM (ang. Optimally Pruned Extreme Learning Machine). Przykładem testowym w tym badaniu jest system elektroenergetyczny South Sulawesi-Indonesia, z całkowitą penetracją turbin wiatrowych 142 MW. Z symulacji widać, że OP-ELM może bardzo dobrze wykonywać prognozy ze wskaźnikiem błędu 0,0886%.
EN
The frequent problem of voltage collapse in the distribution system can be mitigated through the application of the sensitivity-index-based optimization technique. The proposed method is used to identify those weak buses that are susceptible to voltage collapse within the distribution system. The identified weak buses are then optimally connected with distributed generation (DG). This will affect voltage improvement, power loss reduction, and general reliability of the system. A 30-bus 33kV feeder distribution network system is used to measure the efficacy of the proposed method. Buses 19, 22, and 30 have the greatest potential for voltage collapse in the system among all the selected candidate buses, according to the results. Bus 30, on the other hand, has the highest power KOS sensitivity index, making it the best position for the DG. The total active power loss (APL) of the network was reduced to 16.8% after effective implementation of the mitigation measures. The buses that were prone to voltage collapse which run below the statutory voltage limit (0.95 p.u ≤ Vi ≤ 1.05 p.u.) were also improved to a standard working level.
PL
Częsty problem zapadu napięcia w systemie dystrybucyjnym można złagodzić poprzez zastosowanie techniki optymalizacji opartej na indeksie wrażliwości. Zaproponowana metoda służy do identyfikacji tych słabych szyn, które są podatne na zanik napięcia w systemie dystrybucyjnym. Zidentyfikowane słabe magistrale są następnie optymalnie połączone z generacją rozproszoną (DG). Wpłynie to na poprawę napięcia, zmniejszenie strat mocy i ogólną niezawodność systemu. Do pomiaru skuteczności proponowanej metody stosowany jest 30-szynowy system sieci dystrybucyjnej z zasilaczem 33 kV. Zgodnie z wynikami, autobusy 19, 22 i 30 mają największy potencjał zaniku napięcia w systemie spośród wszystkich wybranych szyn kandydujących. Z kolei autobus 30 ma najwyższy wskaźnik czułości KOS mocy, co czyni go najlepszą pozycją dla DG. Całkowita utrata mocy czynnej (APL) sieci została zmniejszona do 16,8% po skutecznym wdrożeniu środków łagodzących. Szyny podatne na zaniki napięcia, pracujące poniżej ustawowego limitu napięcia (0,95 p.u ≤ Vi ≤ 1,05 p.u.), również zostały ulepszone do standardowego poziomu roboczego.
PL
W artykule analizowany jest wpływ podłączenia systemu fotowoltaicznego na na stabilność napięcia w radialnym systemie energetycznym IEEE 69. Analizowane są zależność P-V oraz indeks stabilności napięciowej IVSI. Podłączenie systemu fotowoltaicznego poprawia margines obciążenia sieci.
EN
This paper analyses the effect of grid-connected PV systems on static voltage stability using the IEEE 69 radial distribution system. The effect of integrating PV generators into power systems with higher PV penetration level and multiple numbers of PV generators is analyzed using PV curve and improved voltage stability index (IVSI). The P-V curve data show that grid-connected PV systems improve loading margin and voltage magnitude. The IVSI gives a positive output because systems with integrated PV generators reach the voltage collapse point.
5
Content available remote Under Voltage Load Shedding Scheme Using Meta-heuristic Optimization Methods
EN
Load shedding has been extensively studied because of multiple power system failure occurrences worldwide. Reliable techniques are required to provide rapid and precise load shedding to avert voltage collapse in power networks. Meta-heuristic optimization approaches are currently the widely developed methods because of their robustness and flexibility in dealing with complex and non-linear systems. These methods include genetic algorithm, fuzzy logic control, particle swarm optimization, artificial neural network, ant colony optimization, big-bang big-crunch optimization, and many others. This study provides an overview of all the meta-heuristic methods implemented for under voltage load shedding in power systems.
PL
Pozbywanie się obciążenia jest istotne z punktu widzenia możliwego zapadu systemu przesyłu energii. Do tego celu wykorzystuje się optymalizację meta-heurystyczną głównie dzięki odporności i szerokim możliwościom. W skład metody wchodzą: algorytm genetyczny, logika rozmyta, algorytmy mrówkowe, sieci neuronowe. W artykule dokonano przeglądu tych metod.
6
Content available remote Review of Under-voltage Load Shedding Schemes in Power System Operation
EN
A voltage collapse event is complex and localized in nature, but its effect is extensive. A vital effect of voltage collapse is total system collapse or blackouts, which will result in a significant loss to utility companies. Online monitoring of power system stability has thus become an important factor for electric power utilities. The final resort prevent the occurrence of a voltage collapse incident is the implementation of an undervoltage load shedding (UVLS) scheme. This paper focuses on the introduction of the UVLS scheme and presents an overview of the principles of the UVLS that are crucial to the design of such a protection scheme. This paper also presents the existing industrial practices and other research methods available to date.
PL
W artykule opisano algorytm UVLS (Under Voltage Shedding Schemes) zastosowany do monitorowania stabilności systemu energetycznego I zapobiegania jego zapaściom. Artykuł jest przeglądem metod stosowanych w praktyce oraz prac badawczych w tej dziedzinie.
PL
W artykule pokazano wyniki badań dotyczących współpracy generatora 17,4 MVA z elektroenergetyczną siecią rozdzielczą. Na potrzeby przeprowadzenia badań, w środowisku Matlab - Simulink, wykonano model przykładowej sieci oraz generatora wraz z regulatorem AVR i modelem turbiny gazowej. Przeprowadzono badania wpływu zapadów napięcia na pracę generatora zainstalowanego w zakładzie przemysłowym, który jest zasilany linią kablową z rozdzielni 110kV/15kV. Szczególnie zwrócono uwagę na zapady napięcia powstałe na skutek zwarć, występujących w różnych miejscach testowej sieci. Zamieszczone w artykule wyniki badań mogą przyczynić się do określenia wymagań dotyczących odporności elektromagnetycznej, jakie muszą spełniać urządzenia wytwórcze współpracujące z siecią SN. Mogą one także posłużyć do zaproponowania nowych rodzajów zabezpieczeń lub zmian nastaw istniejącej automatyki zabezpieczeniowej, w obliczu przewidywanego dalszego rozwoju generacji rozproszonej.
EN
This article shows the simulations & results analysis of a 17.4MVA generator running in parallel with the grid. The aim of this simulation is to establish what influence the system voltage collapse has on the generator running. The generator is installed at industrial plant and connected via cable to 110kV/15kV substation. Gas turbine, generator, AVR system, and utility models were created in SIMULINK, which is an extension of MATLAB. Different kind of faults and fault location were simulated. The results obtained from this research can contribute to further development works, propose new protection settings and help to understand what technical requirements are needed by power system in order to maintain stability. During any stage of evolution of the power system, there is always a place
PL
Bezpieczny przesył energii elektrycznej może się odbywać, gdy spełnione sa jednocześnie i z określonym zapasem wszystkie warunki wynikające z istniejących ograniczeń technicznych, a mianowicie: obciążlności termicznej linii i transformatorów, stabilności napięciowej oraz kątowej generatorów. W artykule szczególną uwagę poświęcono ograniczeniom przesyłu mocy wynikającym z warunku stabilności napięciowej. Podkreślono znaczenie badania stabilności napięciowej w ramach planowania pracy sieci przesyłowej i przedstawiono praktyczne sposoby ich wykonywania. Wykorzystując przykład awarii napięciowej w dniu 26 czerwca 2006 omówiono rolę układów regulacji i automatyki przeciwawaryjnej oraz funkcję Operatora Systemu w zapobieganiu lawinie napięcia.
EN
From the point of view of secure transmission of electrical energy, thermal limit of EHV lines, voltage and angle stability limit of transmission subsystems are very important. In this paper, it is shown that the voltage stsbility may still dictate the transfer limits. the reactive power reserves and voltage limits should be proper planned to maintain the security of transmission. the difficulties of voltage stability analysis are mainly linked to the unavoidable uncertainties in the operationprocess and to the occurrence of unpredicted contingencies or abnormal equipment behaviour in real time operation. Voltage phenomena associated with the voltage collapse occured on 26 June 2006 in Polish power system has been described to show possible remedial measures taken by Operator to prevent voltage collase and then recover voltage. Some propositions of improvement in planning, operation and control has been formulated as well.